Customer Ser
vice
Tr
oubleshooting T
ips
Operating Instr
uctions
Safety Infor
mation
Purging the Reverse Osmosis System
RO produce
water faucet
3/8
″
tubing, marked FAUCET
Sink
p-trap
3/8
″
tubing x 27
″
, to
3/8
″
barb on faucet
1/4
″
tubing, marked
WATER SUPPLY
Electronic
box
Flow
Drain
clamp
Tank shutoff valve
CLOSED
OPEN
Water supply/
saddle valve
Lead wires
Battery pack
1/4
″
tubing,
marked
1/4
″
BARB
Shutoff
assembly
11
Required upon installation and after the Reverse Osmosis cartridge
is replaced.
Make sure all tubing connections are tightened.
Open the tank shutoff valve. Turn on the water supply to the
Reverse Osmosis system.
In about four hours, pressure will start to build in the Reverse
Osmosis system.
At that time,
carefully check all fittings and
tubing connections for any water leaks. Correct leaks if any are
found. Open the faucet to drain the storage tank.
CAUTION:
The Reverse Osmosis cartridge contains a food grade
preservative that should be purged from the system before use. The
preservative will give product water an unpleasant taste and odor. After
the tank has filled (takes about four hours), open the system faucet until
the bladder is empty.
After four of these drainings, the system is ready to make
product water for your use.
4
3
2
1