46
49-60647-5
Performance Data Sheet
Model GE Appliances XWF
sheet and at iapmort.org.
maintenance and filter replacement requirements be carried out for the
information.
Application Guidelines/Water Supply Parameters
0.5 gpm (1.89 lpm)
Water Supply
Potable Water
Water Pressure
25-120 psi (172-827 kPa)
Water Temperature
Capacity
170 gallons (643.5 liters)
Substance Tested for Reduction
concentration
(mg/L)
Maximum permissible
product water
concentration (mg/L)
Avg
Reduction
Chlorine Taste and Odor
N/A
96.9
Chloramine Taste and Odor
0.5
96.9
At least 10,000/mL
N/A
91.4
Cysts
50,000/L
N/A
>99.99
Lead
0.15
0.01
98.85
Mercury
0.006
0.002
96.3
Asbestos
107 to 108 fibers/ L
N/A
>99
Toxaphene
0.003
86.95
VOC (Chloroform surrogate chemical)
0.300
0.015
99.7
Alachlor
0.050
0.001
> 98
0.100
0.003
> 97
0.081
0.001
> 99
Carbofuran
0.190
0.001
> 99
carbon tetrachloride
0.078
0.0018
98
0.077
0.001
> 99
chloropicrin
0.015
0.0002
99
0.110
0.0017
98
0.052
0.00002
> 99
0.08
0.001
> 99
0.040
0.001
> 98
1,2-dichloroethane
0.088
0.0048
95
1,1-dichloroethylene
0.083
0.001
> 99
cis-1,2-dichloroethylene
0.170
0.0005
> 99
trans-1,2-dichloroethylene
0.086
0.001
> 99
1,2-dichloropropane
0.080
0.001
> 99
cis-1,3-dichloropropylene
0.079
0.001
> 99
dinoseb
0.170
0.0002
99
Endrin
0.053
0.00059
99
0.088
0.001
> 99
0.044
0.00002
> 99
bromochloroacetonitrile
0.022
0.0005
98
dibromoacetonitrile
0.024
0.0006
98
dichloroacetonitrile
0.0096
0.0002
98
trichloroacetonitrile
0.015
0.0003
98
1,1-dichloro-2-propanone
0.0072
0.0001
99
1,1,1-trichloro-2-propanone
0.0082
0.0003
96
heptachlor (H-34, Heptox)
0.025
0.00001
>99
heptachlor epoxide
0.0107
0.0002
98
hexachlorobutadiene
0.044
0.001
> 98
hexachlorocyclopentadiene
0.060
0.000002
> 99
Lindane
0.055
0.00001
> 99
methoxychlor
0.050
0.0001
> 99
pentachlorophenol
0.096
0.001
> 99
0.120
0.004
> 97
Styrene
0.150
0.0005
> 99
1,1,2,2-tetrachloroethane
0.081
0.001
> 99
Tetrachloroethylene
0.081
0.001
> 99
Toluene
0.078
0.001
> 99
2,4,5-TP (silvex)
0.270
0.0016
99
tribromoacetic acid
0.042
0.001
> 98
0.160
0.0005
> 99
1,1,1-trichloroethane
0.084
0.0046
95
1,1,2-trichloroethane
0.150
0.0005
> 99
trichloroethylene
0.180
0.0010
> 99
bromoform
0.300
0.015
95
bromodichloromethane
0.300
0.015
95
chlorodibromomethane
0.300
0.015
95
xylenes
0.070
0.001
>99
Meprobamate
60
95.5
Atenolol
30
95.9
200
98.6
200
98.6
Metolachlor
200
98.7
Trimethoprim
20
96.1
Linuron
20
96.6
TCEP
700
98.1
TCPP
700
98.1
Phenytoin
30
96
60
95.9
Naproxen
20
96.5
Estrone
20
97.1
Bisphenol A
300
99.1
Nonyl phenol
200
97.3
NOTE
While the testing was performed under standard
laboratory conditions, actual performance may vary.
replacement elements please call 1.877.959.8688 or visit our
website at
gewaterfilters.com
.
To reduce the risk associated with
ingestion of contaminants
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection
before and after the system.
Systems certified for cyst
reduction may be used on disinfected water that may contain
filterable cysts.
NOTICE
To reduce the risk of water leakage or flooding, and to
ensure optimal filter performance
Read and follow
use instructions before installation and
use of this system.
MUST
comply with all state and local
plumbing codes.
Do not
install if water pressure exceeds 120 psi (827
must
install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water
pressure.
Do not
install where water hammer conditions may occur.
must
install a water
hammer arrester. Contact a plumbing professional if you are
uncertain how to check for this condition.
Do not
install on hot water supply lines. The maximum
(38 C).
Protect filter from free ing.
Change the disposable filter cartridge every six months or
sooner if you observe a noticeable reduction in water flow
rate.
recommended intervals may lead to reduced filter
performance and cracks in the filter housing, causing water
leakage or flooding.
53 and 401 for the reduction of the substances listed below.
The concentration of the indicated substances in water
entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the
XWF System is certified by IAPMO R&T
against NSF/ANSI Standards 42,53, and 401
for the reduction of claims specified on the
performance data sheet and at iapmort.org.
Summary of Contents for SIDE-BY-SIDE REFRIRATOR 22
Page 1: ......
Page 47: ...49 60647 5 47 Notes...