6150-ID Sharpshooter PIR
Installation Instructions

Specifications

Housing material

Flame retardant ABS

Operating voltage

8 to 27V (as supplied by the
PinPoint bus)

Current draw

250µA typical average
3 mA with LED momentarily on

Transmit condition

Alarm, tamper

Detection range

45 ft. (13.7 m)

Operating temperature

32 to 131°F (0 to 55°C)

Relative  humidity

10 to 90% non-condensing

Maximum line length

10,000 ft. (3 km)

Standard swivel bracket

± 10° left/right, 10° up, 15° down

LED indicator

Walk  test

Dimensions:

Width

2.9 in. (74 mm)

Depth

2.4 in. (61 mm)

Height

3.7 in. (94 mm)

Color

Off-white

Coverage Patterns

Standard (installed) 45 ft. x 90°
Long Range (optional) 90 ft. x 6°
Curtain (optional) 40 ft. x 6°
Pet Alley (optional) 35 ft. x 90°
Extra Wide Angle (optional) 20 ft.
x 140°

Listings

FCC, CE

GE Security

12345 SW Leveton Drive

Tualatin, OR 97062

503-692-4052

USA & Canada: 800-547-2556
Tech Support: 800-648-7424
www.gesecurity.com
1042134 Rev B     September 2004

FCC compliance

This device complies with Part 15 of the FCC rules. Operation is
subject to the following conditions:
1.

This device may not cause harmful interference.

2.

This device must accept any interference received, including
interference that may cause undesired operation.

Product ordering

Product

Description

6150-ID

Addressable, passive infrared motion

sensor for use with the PinPoint bus

with swivel bracket and standard lens

Lenses

6070

Standard lens, 45 ft. (13.7 m) x 90°

6071

Long range lens, 90 ft. (27.4 m) x 6°

6072

Extra wide angle lens, 20 ft. (6.1 m) x

140°

6073

Curtain lens, 40 ft. (12.2 m) x 6°

6074

Pet alley lens (12° tilt), 35 ft. (10.7 m)

x 90°

6077

Pet alley lens (non-tilt), 35 ft. (10.7 m)

x 90°

6076

Single beam pet alley, 50 ft. (15.2 m) x

6°

Summary of Contents for SHARPSHOOTER 6150-ID

Page 1: ...false alarm free operation no part of an unwanted hot spot should enter any part of a zone Locate for cross traffic Figure 3 Place the unit where intruders move across the beams not toward the unit For best detection an intruder should cross the entire zone Donotblockthecoveragepattern Figure4 The unit requires a clear line of sight Inform end users not to block the coverage pattern with inventory...

Page 2: ...ensitivity DIP switches Figure 6 See DIP switches 5 Set the PinPoint address DIP switches Figure 6 Devices are shipped with DIP switches set to 255 This is an invalid address The device will not communicatewiththecontrollerandthewalktest LEDwillnotlightuntilavalidaddresshasbeenset Refer to the controller s manual to determine the correct address setting for each unit 6 Pull the PinPoint wiring thr...

Page 3: ...curtain applications It requires the intruder to only pass through one curtain to triggeranalarm Notes Operation in the standard curtain mode is for the specified ranges of 33 feet 10 1m and 45 feet 13 7 m For operation in bi curtain mode the unit has 30 feet 9 1m of range only For ranges from 30 to 45 feet 9 1 to 13 7 m the unit will provide detection within 6 steps or 14 feet 4 3 m across the pl...

Page 4: ...tain areas are entered The LED visible on the front cover lights to indicate an alarm 4 Walk test the detection pattern and make any necessary adjustments 5 Replace and walk test the unit to verify the unit is communicatingwiththecontroller Note After the walk test mode times out in 3 to 4 minutes the unit returns to normal operating mode In normal operating mode the unit LED is disabled to reduce...

Page 5: ...t 6 1m 20ft 6 1m 6ft 10in 2 1m 0 Topview Sideview Figure 15 Pet alley 35ft 10 7m 0 35ft 10 7m 35ft 10 7m 0 3 ft 3 in 1 0m Topview Sideview 45ft 13 7m 40ft 12 2m 30ft 9 1m 20ft 6 1m 10ft 3 0m 0 0 10ft 3 0m 20ft 6 1m 30ft 9 1m 40ft 12 2m 45ft 13 7 m 6ft 10in 2 1m 60 30 15 Topview 4 Sideview 36 36 0 6 6ft 10in 2 1m 7ft 6in 2 3m 9ft 2 7m 90 27 5m Topview Sideview ...

Page 6: ...tional 20 ft x 140 Listings FCC CE GE Security 12345 SW Leveton Drive Tualatin OR 97062 503 692 4052 USA Canada 800 547 2556 Tech Support 800 648 7424 www gesecurity com 1042134 Rev B September 2004 FCC compliance This device complies with Part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interfe...

Reviews: