GE RX3i PROFINET Quick Start Manual Download Page 8

8

 

 

IC695PNC001-AJ PROFINET Controller Module

 

GFK-2573K 

Important Product Information for this Release 

Upgrades 

The PNC can be field-upgraded to firmware version 2.11 using the Winloader firmware upgrade kit 

82A1790-MS10-000-A9, which can be downloaded fro

http://support.ge-ip.com.

 

Compatibility 

The following CPU firmware, programming software and backplane hardware versions are required to use the features 

introduced in PNC release 2.11 and later: 

Subject 

Feature 

Minimum Version Required 

PLC CPU Firmware 

Version Requirements  

RX3i PNC001 release 2.11 (or later)  

Hot Standby Redundancy with PROFINET I/O 

CRU320 Primary Firmware Release 8.40 
CRU320 Boot Firmware Release 5.10 
(Other CPU models are not supported) 

RX3i  PNC001 Release 2.00 
Hot Standby Redundancy with PROFINET I/O 

CRU320 Primary Firmware Release 8.00 

CRU320 Boot Firmware Release 5.10 
(Other CPU models are not supported) 

Non Hot Standby Redundancy system 

CPU320/CPU315 Primary Firmware Release 7.13 
CPU320/CPU315 Boot Firmware Release 5.10 
CPE310/CPE305 Primary Firmware Release 7.10 
CPE310/CPE305 Boot Firmware Release 7.10 
CRU320 Primary Firmware Release 8.00 
CRU320 Boot Firmware Release 5.10 
(Other CPU models are not supported) 

Programmer version 

requirements 

RX3i PNC001 Release 2.11 (or later) 

 

128 Profinet Device Support

††

 

 

“Critical Network Port”

 ††

 

PME 8.50 SIM 9 or 8.60 SIM 1  

RX3i PNC001 Release 2.00 (or later)  
Hot Standby Redundancy with PROFINET I/O 
Non Hot Standby Redundancy system using 

CRU320 

Proficy Machine Edition 8.00 SIM 5 

RX3i PNC001 Release 2.00 (or later) 
Non Hot Standby Redundancy system 

Proficy Machine Edition 7.00 SIM 8 

VersaMax PROFINET 

Scanner 

As a redundantly-controlled I/O Device 

IC200PNS001/0 Firmware Release 2.00 

As a simplex I/O Device 

IC200PNS001/002 Firmware Release 1.00 

†† 

Attempts to store a configuration utilizing this feature to a prior-release PNC will result in an “Unable to deliver configuration to 

module” fault, leaving the PNC un-configured. 

New Features and Enhancements 

Firmware version 2.11 adds support for the following new features: 

 

Increased number of Profinet Devices that PNC can control from 64 to 128. 

 

Added new “SFP OK” status bits to existing PNC status dword. 

 

Introduced new “Critical Network Port” diagnostic fault configuration and logging.   

Problems Resolved in This Release 

None 
 

 

Summary of Contents for RX3i PROFINET

Page 1: ...ation via the micro USB port or using telnet Note The USB port is for system setup and diagnostics only It is not intended for permanent connection Support for star ring and daisy chain line network t...

Page 2: ...Control 10 100 1000 Mbps Maximum I O Memory 128 Kbytes of combined input output memory per PROFINET Controller CPU Status Bits 32 PROFINET I O Device Data Update Rates on the PROFINET LAN Configurable...

Page 3: ...t be installed in an ultimate enclosure that is manufactured to provide safety As a minimum the enclosure shall provide a degree of protection against solid objects as small as 12mm e g fingers This e...

Page 4: ...tion or is not operational 8 Port4 SFP OK Indicates the health of the SFP plugged in port 4 1 indicates that the SFP matches configuration and is operational 0 indicates that either the SFP does not m...

Page 5: ...e RX3i system using a Universal Backplane such as IC695CHS007 CHS012 or CHS016 The PNC supports insertion removal while power is applied to the system hot swap This includes backplane power and field...

Page 6: ...such as Hyperterm The PNC is provided with a driver install application that can be used to enable a computer to communicate with a PNC via its USB port For details on using the Command Line Interfac...

Page 7: ...res and Enhancements on page 8 IC695PNC001 AF 1 23 Aug 2013 Corrects issue storing PROFINET device configuration greater than 64K bytes in size For details see GFK 2573F IC695PNC001 AE 1 22 Jul 2013 C...

Page 8: ...0 CPE310 CPE305 Boot Firmware Release 7 10 CRU320 Primary Firmware Release 8 00 CRU320 Boot Firmware Release 5 10 Other CPU models are not supported Programmer version requirements RX3i PNC001 Release...

Page 9: ...ware configuration or the current hardware configuration in the system is cleared prior to storing a new configuration If the controller is Faulted clear the I O Fault Table to recover Otherwise no ad...

Page 10: ...he failover occurs It is not recommended to use the PNC reset button in a normally operating system If the reset button must be used it is recommended to first attempt a brief press and release of the...

Page 11: ...perly and updates the maximum number of telnet connections log details command response When displaying numerous local log table entries using the log details command sometimes erroneous blank charact...

Page 12: ...t case ring recovery time is 96ms the rate needs to be more than 96ms divided by 3 which is 32ms The next available rate after 32ms is 64ms 16ms When using an I O Update Rate of 16ms you must set the...

Page 13: ...configurations When storing hardware configurations with more than 64 PROFINET I O Devices that include multiple PNC modules and 3rd party PROFINET I O Devices on a single network occasional Loss Add...