6
Performance RHM 12
Max Flow Rate Qmax = 100 kg/min (220 lb/min),
Qnom (*) = 75 kg/min (165 lb/min)
Standard Models
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
100
220
0.20
40
88
0.20
10
22
0.20
5.0
11
0.20
2.0
4.4
0.50
Goldline Models (**) - selected sensors
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
75
165
0.10
40
88
0.10
10
22
0.10
7.50
17
0.10
3.75
8.3
0.12
Low Flow Models (**) - selected sensors
Flow Rate
Uncertainty
kg/min
lb/min
in % of reading
40
88
0.20
20
44
0.20
10
22
0.20
2.0
4.4
0.20
1.5
3.3
0.60
(*) Nominal flow Qnom refers to roughly 8 - 10 m/s (26 -
33 ft/s) velocity in measuring loops for best performance.
(**) Selected sensors are only available in combination
with temperature options T1, TA, standard material and
pressure range.
Repeatability
Better ± 0.1% of rate,
Goldline 0.05%
Density
Down to 0.5% uncertainty
Temperature
Better ± 1°C
• Serial/single path versions offer the same accuracy at
half the flow (Qmax serial version = 50 kg/min).
• No relevant pressure effect due to torsional oscillation
and semi-circle (non-deforming) measurement
section.
• Uncertainty of reading (incl. zero drift) indications refer
to reference conditions H
2
O, 18-24°C (66 - 76°F), 1 - 3
bar (15 – 45 psi) and installation according to field
manual.
• Pressure drop indications refer to H
2
O, with parallel
measuring loops type P1 and standard manifold block
connections.
• For calibration to customer range and / or with
improved uncertainty, please consult factory.
Uncertainty % DP (bar)
Uncertainty % DP (bar)
Uncertainty % DP (bar)
Flow Rate kg/min
Flow Rate kg/min
Flow Rate kg/min