GE QuickPanel Plus IC755CxS06RDx User Manual Download Page 1

GFK-2847Q

QuickPanel

Operator Interface

User Manual

Feb 2016

IC755CxS06RDx (6” Display)

IC755CxW07CDx (7” Display)

IC755CxS10CDx (10" Display)

IC755CxS12CDx (12” Display)

IC755CxS15CDx (15” Display)

For public disclosure

Summary of Contents for QuickPanel Plus IC755CxS06RDx

Page 1: ...K 2847Q QuickPanel Operator Interface User Manual Feb 2016 IC755CxS06RDx 6 Display IC755CxW07CDx 7 Display IC755CxS10CDx 10 Display IC755CxS12CDx 12 Display IC755CxS15CDx 15 Display For public disclosure ...

Page 2: ...r pending patent applications covering subject matter in this document The furnishing of this document does not provide any license whatsoever to any of these patents GE provides the following document and the information included therein as is and without warranty of any kind expressed or implied including but not limited to any implied statutory warranty of merchantability or fitness for particu...

Page 3: ...mic Random Access Memory FG Frame Ground FTP File Transfer Protocol GND Ground GUI Graphical user interface HTTP HyperText Transfer Protocol LCD Liquid Crystal Display LED Light emitting Diode MIB Management Information Base or Database OS Operating System PME Proficy Machine Edition RoHS Restrictions on Hazardous Substances SELV Safety Extra Low Voltage SNMP Simple Network Management Protocol USB...

Page 4: ...result in personal injury or death Caution Indicates a procedure condition or statement that if not strictly observed could result in damage to or destruction of equipment Attention Indicates a procedure condition or statement that should be strictly followed to improve these applications For public disclosure ...

Page 5: ...hnical Support Email support ip ge com Customer Care Email customercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support http support ge ip com Phone 800 1 433 2682 EMEA Direct Dial 420 23 901 5850 if toll free 800 option is unavailable or dialing from a mobile telephone Technical Support Email support emea ip ge com Customer Care Email custo...

Page 6: ...Notes 6 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 7: ...gs Tool 29 3 9 1 Firmware Upgrade 30 3 9 2 Firmware Upgrade for Specific Build Version 32 3 9 3 Bypass Startup Programs 33 3 9 4 Reset Enhanced Security 35 3 9 5 Enable or Disable SNMP Agent 36 3 10 Display Screen Sensitivity Tool 38 3 11 Launch Application 39 3 12 VNC Server 40 3 13 Battery Life Prediction 41 3 14 Simple Network Management Protocol SNMP 45 3 14 1 Configure Trap Destinations 49 3 ...

Page 8: ...CDx and IC755CxSxxCDx 85 5 7 6 Audio MIC IN Details Only Applicable to IC755CxS06RDx and IC755CxW07CDx 85 5 7 7 SD Card Slot and Storage 86 6 Operation 89 6 1 Touchscreen Display 89 6 1 1 Display Brightness Adjustment 89 6 1 2 Display Backlight Configuration 90 6 1 3 Touchscreen Re calibration 91 6 2 Keyboard Configuration 92 6 2 1 External Keyboard Optional 92 6 2 2 Soft Input Panel 92 6 3 Mouse ...

Page 9: ...e QuickPanel communications ports The QuickPanel is equipped with several memory types to satisfy the most demanding applications A section of Dynamic Random Access Memory DRAM is split between the operating system an object store and application memory Additionally a section of Non volatile Random Access Flash Memory NOVRAM functioning as a virtual hard drive is divided between the operating syst...

Page 10: ...Base T 100Base TX Serial Port 1x RS 232C COM1 5 pin connector USB Host 2x USB 2 0 Type A maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Mic In Mono 3 5 mm jack 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise Voltage 1500 V p p Pulse Duration 1µs Rise Time 1ns Input power Rated Voltage 24 V dc 20 3 pin connector Power Consumption 15 W maximum ...

Page 11: ...Serial Port 1x RS 232 UART port 5 pin connector USB Host 2x USB 2 0 Type A maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Mic In Mono 3 5 mm jack 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise voltage 1500 V p p Pulse duration 1µs Rise time 1ns Input power Rated Voltage 24 V dc 20 3 pin connector Power Consumption 15 W maximum 0 625 A Frame ...

Page 12: ...S 232 UART port 1x RS 232 485 port 2x 5 pin connector USB Host 2x USB 2 0 Type A maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise voltage 1500 V p p Pulse duration 1µs Rise time 1ns Input power Rated Voltage 12 24 V dc 20 3 pin connector Power Consumption 18 W maximum 1 5 0 75 A Frame Ground FG Frame...

Page 13: ...2CDA Serial Port 1x RS 232 UART port 1x RS 232 485 port 2x 5 pin connector 1x 10 pin connector for IC755CxS12CDA USB Host 2x USB 2 0 Type A max power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise voltage 1500 V p p Pulse duration 1µs Rise time 1ns Input power Rated Voltage 12 24 V dc 20 3 pin connector Power Co...

Page 14: ...232 UART port 1x RS 232 485 port 2x 5 pin connector USB Host 2x USB 2 0 Type A maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise voltage 1500 V p p Pulse duration 1µs Rise time 1ns Input power Rated Voltage 12 24 V dc 20 3 pin connector Power Consumption 30 W maximum 2 5 1 25 A Frame Ground FG Frame G...

Page 15: ... 60 C 14 to 140 F Ambient Humidity Operating and Storage 85 RH Non condensing wet bulb temperature 30 C 86 F or less Environment Pollution Degree 2 Indoor use only Vibration Resistance 5 to 9 Hz single amplitude 3 5 mm 9 to 150 Hz constant accelerated velocity 9 8 m s2 X Y Z directions 10 time 100 minutes Compliance 3502 IEC61131 2 JIS B Altitude 800 1114 hPa altitude up to 2000 m 6561 68 ft RoHS ...

Page 16: ...Notes 16 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 17: ...cteristics In addition to the primary touchscreen interface the QuickPanel Operator Interface supports a variety of communication ports The following diagrams illustrate the physical layout of the QuickPanel Operator Interface including locations of status LEDs communications ports and connectors Hardware GFK 2847Q 17 For public disclosure ...

Page 18: ... 4 in 115 2 4 5 in 192 7 56 in x 2 36 1 42 in x 2 137 5 39 in x 2 183 50 7 22 in 75 2 95 in 75 2 95 in 128 50 5 06 in 144 7 5 70 in Effective Screw Depth 6 mm 0 24 in Product Nameplate Battery Cover License Label IC755CxS06RDx Hardware Features 18 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 19: ... Input Power SD Card MICRO USB LINE OUT MIC IN Status Indicator LED Touchscreen LCD IC755CxW07CDx Hardware Features Note Refer to the section IC755CxW07CDx Specifications for drawing dimensions Hardware GFK 2847Q 19 For public disclosure ...

Page 20: ... Host Ports MICRO USB LAN2 COM1 LAN1 Input Power LINE OUT COM2 IC755CxS10CDx Hardware Features Note Refer to the section IC755CxS10CDx Specifications for drawing dimensions 20 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 21: ... IC755CxS12CDx Hardware Features Note Refer to the section IC755CxS12CDx Specifications for drawing dimensions Hardware GFK 2847Q 21 For public disclosure ...

Page 22: ...ut Power LINE OUT USB Host Ports MICRO USB COM2 LAN2 COM1 LAN1 IC755CxS15CDx Hardware Features Note Refer to the section IC755CxS15CDx Specifications for drawing dimensions 22 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 23: ...W07CDx the and IC755CxSxxCDx units LED State QuickPanel State Amber solid Operating system starting Green solid Normal operating state Green blinking Backlight off Red blinking Backlight failure Off Power not applied to unit 2 2 2 Ethernet Port Operation LEDs The Ethernet port has two LED indicators Speed and Link Activity Speed Link Activity LED LED State Operating State Speed Yellow on 10 100 Li...

Page 24: ...Notes 24 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 25: ...is not battery powered therefore a Backup Utility feature saves the changes made to the Windows Registry or Desktop to Flash Memory The Backup Utility achieves the following Stores the Windows Embedded Compact 7 registry including any control panel settings in Flash memory Stores changes or additions made to the Windows sub tree of the file system in the user block of flash memory 3 3 Storage Mana...

Page 26: ...ficy Machine Edition Project Update Update a Proficy Machine Edition PME application that is currently stored on the QuickPanel unit with a revision stored on a flash device such as an SD card To update a Machine Edition project 1 Insert the flash device containing an upgraded version of the Proficy Machine Edition project into the appropriate port 2 Restart the unit Note Depending on set options ...

Page 27: ...n The FTP root directory is available from the QuickPanel as and is the root of the flash device The server only supports anonymous login with password requested but not validated This may prevent some types of attacks and is required by some clients Once connected the remote user is logged into the FTP root directory 3 6 2 FTP with Removable Flash Devices All removable flash devices remote FTP us...

Page 28: ...ration Note If the server status is changed the QuickPanel must be restarted before changes take effect 3 8 SNTP Server The SNTP server included with the QuickPanel supports SNTP Version 4 for IPv4 IPv6 and OSI The SNTP server is configured with the Quick Panel Setup Tool By default the server is not enabled Once enabled the server will refresh the time specified in the setup tool configuration Pr...

Page 29: ...n As an alternative to using the DIP Switch settings the QuickPanel OS Utilities Settings tool contains finger gesture based utilities to perform the same operations This functionality is available with the firmware builds listed in the following table QuickPanel OS Utilities Settings Tool Support QuickPanel Product Firmware Build IC755CxS06RDx 6 Display 01 initial release IC755CxW07CDx 7 Display ...

Page 30: ...de which refreshes the device fresh the user must download the project again and install their own tools including third party tools on the device Note It is recommended that the user back up any important data prior to firmware upgrade so that they can replace the data after firmware upgrade if necessary Attention If the current firmware build version on the QuickPanel is any of the following ref...

Page 31: ...e tap Upgrade 3 The operator interface guides the operator through the firmware upgrade process After successful upgrade restart the device 4 Download the project and install any site specific tools including third party tools on the device Software GFK 2847Q 31 For public disclosure ...

Page 32: ... version 1 Put the files in the firmware package on the SD Card 2 Double click QPPlusUpdate exe and run the program 3 Perform the firmware upgrade From the QuickPanel Update Tool dialog box click Upgrade Attention For a QuickPanel 7 inch Display unit the following message displays during the process of firmware upgrade You must re run the QPPlusUpdate exe program after reboot which means you will ...

Page 33: ...ion To bypass startup programs and force startup 1 From the Start menu select Programs System and QuickPanel OS Utilities Settings Tool to display the QuickPanel OS Utilities Settings window 2 Enable or disable the bypass startup programs feature From the QuickPanel OS Utilities Settings window select Bypass Startup Programs To use the DIP Switch feature to perform this operation select Use DIP Sw...

Page 34: ...uble tapped the startup window displays Click Don t run Startup programs to stop all startup programs from running If Use DIP Switch is selected Don t run StartUp Programs displays on the startup window based on the position of DIP Switch 2 34 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 35: ... on the device by permitting the user to disable the Enhanced Security feature using the double tap feature Note Prior to support of the QuickPanel OS Utilities Settings Tool if the user forgot or did not know their password the only resolution was to contact Technical Support to reset the password or upgrade the firmware on the device To disable Enhanced Security 1 From the Start menu select Prog...

Page 36: ...section Simple Network Management Protocol SNMP for further details Note Enabling or disabling SNMP communication is a one time user configuration To enable the SNMP Agent 1 From the Start menu select Programs System and QuickPanel OS Utilities Settings Tool to display the QuickPanel OS Utilities Settings window 2 Enable SNMP communication From the QuickPanel OS Utilities Settings window select SN...

Page 37: ...the SNMP Agent 1 From the Start menu select Programs System and QuickPanel OS Utilities Settings Tool to display the QuickPanel OS Utilities Settings window 2 Disable SNMP communication From the QuickPanel OS Utilities Settings window select SNMP Double tap Disable to disable SNMP communication Software GFK 2847Q 37 For public disclosure ...

Page 38: ...h the user wearing most types of work gloves For thicker gloves the user may need to press down more firmly to place the finger closer to the screen which causes the finger pad to spread out slightly to make a larger capacitive area Note Gloved operation works best when the operator is wearing gloves that fit If the fingers do not extend to the end of the glove the empty space at the fingertip may...

Page 39: ...ions To launch an application From the Start menu select Programs System and Launch Application From the Launch Application window tap an application icon to start the application If the application is not listed select to browse for and select an application then click to open start the application Software GFK 2847Q 39 For public disclosure ...

Page 40: ...nt upon user authentication with the correct password User password entry is validated with the Enhanced Security password If the Enhanced Security feature is disabled for the device the VNC Server does not enforce authentication of VNC Viewers The VNC Server is automatically launched during QuickPanel startup It can also be launched manually from the Launch Application To manually launch the VNC ...

Page 41: ...nd select the BatteryStatus tab Battery Life Prediction Example Note If the current time is not set on the device the QuickPanel Setup Tool dialog box will not be capable of provide an accurate battery life prediction To set the current time to display battery life prediction 1 If the current time is not set on the device the QuickPanel Setup Tool displays the following message stating that the cu...

Page 42: ...attery Life Prediction Displayed After Current Time Set 3 If the battery was replaced or removed on the QuickPanel QuickPanel Setup Tool BatteryStatus displays two possible scenarios related to the battery The battery life prediction is estimated based on this selection Battery Status Options 42 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 43: ...the option The battery was replaced is selected enter the date of when the battery was first used in a QuickPanel device This date should reflect the date of first use in any QuickPanel device not just the current device Select the date from the calendar and click Next 6 Enter the current date Select the current date and from the calendar and click Apply Software GFK 2847Q 43 For public disclosure...

Page 44: ...l Setup Tool dialog box to display the battery life prediction information Close and Reopen Message Battery Life Prediction Example after Battery Replacement 44 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 45: ...1 6 2 I O V a l u e s P o r t 1 6 1 U D P SNMP Manager QuickPanel Management Information Base MIB Overview The QuickPanel SNMP Agent maintains a MIB that describes the managed device parameters like HMI Tags alarms and such The SNMP Manager uses the MIB to request specific information for the SNMP Agent and translates the information as needed for the SNMP Managers or Network Management System NMS...

Page 46: ... It is highly recommended that you pre load GE MIBs GEIP SMI txt and GEIP PRODUCTS MIB txt in sequence prior to loading the QuickPanelMIB mib file into SNMP Managers to avoid any MIB compiler errors Contact technical support or download the MIBs GEIP SMI txt and GEIP PRODUCTS MIB txt from the Support Site and QuickPanelMIB mib can be copied from the QuickPanel device by performing the procedure Ex...

Page 47: ...mation with alarm objects as part of the Alarm Record The SNMP Manager is notified with the TRAP information when alarms are generated on the HMI running on a QuickPanel device OID for Alarm Trap 1 3 6 1 4 1 24893 1 5 2 1 1 10 Software GFK 2847Q 47 For public disclosure ...

Page 48: ...lated within the hmiTags node of MIB tree and the HMI Tag access level is currently restricted to Read only for the SNMP Manager OID for starting HMI Tag element also called Index element 1 3 6 1 4 1 24893 1 5 2 1 1 50 1 1 If there are 40 HMI tags in total the last OID would be 1 3 6 1 4 1 24893 1 5 2 1 1 50 1 40 48 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 49: ... Destinations IP Addresses Note If you do not want to be notified of Traps you do not need to configure Trap Destinations To configure Trap Destinations Attention If Trap Destination s is are configured after enabling the SNMP Agent on the device it is highly recommended that you disable and then re enable the SNMP Agent service on the device 1 From the Start menu select System open the QuickPanel...

Page 50: ...recommended that you pre load GE MIBs GEIP SMI txt and GEIP PRODUCTS MIB txt in sequence prior to loading the QuickPanelMIB mib file into SNMP Managers to avoid any MIB compiler errors Contact technical support or download the MIBs GEIP SMI txt and GEIP PRODUCTS MIB txt from the Support Site and QuickPanelMIB mib can be copied from the QuickPanel device by performing the following procedure To exp...

Page 51: ... a folder on a machine running with SNMP Manager To load the MIB into the SNMP Manager from the SNMP Manager tool File menu select Load the MIBs Loading MIBs in 3rd Party SNMP Manager Tool If there are no errors the MIB will be loaded successfully and the SNMP Manager will be ready for communication with QuickPanel device operating as a SNMP Agent Software GFK 2847Q 51 For public disclosure ...

Page 52: ...NG DISPLAYSTRING Note The PME VIEW LREAL data type is mapped to DISPLAYSTRING to retain the data intact You can continue to use the data type override suffix mechanism in PME for the LREAL data type to represent a INT DINT if you have configured the data type for driver variables This enables you to map to the DISPLAYSTRING data type in the SNMP communication as well For example for the GE SRTP dr...

Page 53: ...u do not need to configure Trap Destinations 3 Enable a SNMPAgent 4 Export the MIB to a SD Card 5 Auto discover or connect the QuickPanel SNMP Agent from the SNMP Manager Once connected load the MIB to the SNMP Manager tool The SNMP Manager communicating with QuickPanel device can query values for HMI Tags and receive Alarms Trap notification from the QuickPanel device operating as a SNMP Agent Ti...

Page 54: ...Notes 54 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 55: ...age incurred during shipment For phone numbers and email addresses refer to the section Contact Information After unpacking the unit record all serial numbers These are needed to contact Customer Care during the warranty period Save all shipping containers and packing material for future transport or shipping Verify that all system components have been received and agree with the order If the syst...

Page 56: ...wer Connector Qty 1 Mounting Brackets Qty 4 Protective Sheet Qty 1 not shown Gasket Qty 1 not shown pre installed QuickPanel Operator Interface IC755CxWxxCDx Example Package Contents 56 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 57: ...pansion adapters Warning To avoid personal injury or damage to equipment ensure that the dc supply is disconnected from power and the leads are not energized before attaching them to the unit s power supply plug Warning If this equipment is used in a manner not specified by the manufacturer equipment protection may be impaired Power Supply Optional Ethernet Connection Optional USB Keyboard and Mou...

Page 58: ... cable is not energized 2 Loosen the screw clamps on the mating power connector 3 Strip the insulation from the power cables 4 Secure the power cable to the mating connector noting polarity and tighten the screw clamps The torque for the attaching screws is 0 3 Nm 2 66 in lb 5 Apply dc power to the unit During normal startup and operation the QuickPanel status LED indicator displays as follows Sol...

Page 59: ...on It is recommended to set a unique Device Name for the QuickPanel to avoid future conflicts 4 From the Control Panel double tap Network and Dial up Connections to configure network settings 5 Run the Backup Utility to save the settings 4 4 Runtime Setup To download an application to a QuickPanel Operator Interface set up a data link between the unit and the development workstation Refer to the s...

Page 60: ... In general programs are retained in flash memory and user data can be retained in BBSRAM Some operating system settings are retained only with user intervention Perform the following procedure to properly shut down the QuickPanel unit To shut down the QuickPanel unit 1 Quit any programs that are running and wait for all file operations to complete 2 If you have not changed operating system settin...

Page 61: ...ive Sheet Installation To install the protective sheet 1 Remove the protective film from the QuickPanel display screen 2 Wipe the display unit of any dust or fingerprints 3 Peel back a corner of the clear side of the protective sheet 4 Begin applying the corner to the display screen 5 Slowly apply the rest of the protective sheet smoothing out as you go 6 Peel the green curing film from the protec...

Page 62: ...insert and remove the SD card cables and mounting brackets Select a location that allows natural convection air flow from bottom to top of the QuickPanel enclosure Do not mount the QuickPanel at an angle more than 30 from the vertical as illustrated in the following figure Mounting Angle 62 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 63: ...One 2 Phillips head screwdriver Mounting brackets supplied The mounting holes for IC755CxS06RDx IC755CxW07CDx and IC755CxS10CDx are located on the top and bottom sides of the unit IC755CxS06RDx Mounting Holes IC755CxW07CDx Mounting Holes Mounting and Installation GFK 2847Q 63 For public disclosure ...

Page 64: ...ting Holes The IC755CxS12CDx and IC755CxS15CDx mounting holes are located on the top bottom and sides of the unit IC755CxS12CDx Mounting Holes 64 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 65: ...IC755CxS15CDx Mounting Holes Mounting and Installation GFK 2847Q 65 For public disclosure ...

Page 66: ...hrough the cutout with any cables connected or with the power supply plug inserted in the socket Caution When installing the QuickPanel into the panel pay careful attention while handling the unit so it does not drop and damage the unit To install the QuickPanel 1 Cut an opening in the panel according to the specifications in the following figures Note Panel cutout tolerances are 0 50 0 00 mm 0 02...

Page 67: ...g hole as displayed in the following figure 5 Tighten the screws on the mounting bracket in a clock wise direction Torque Range for Mounting Clamp Screws Display Unit Torque Range IC755CxS06RDx 0 3 Nm 2 66 in lb IC755CxW07CDx 0 3 Nm 2 66 in lb IC755CxS10CDx 0 7 Nm 6 in lb IC755CxS12CDx 1 0 to 1 2 Nm 8 9 to 10 6 in lb IC755CxS15CDx 1 0 to 1 2 Nm 8 9 to 10 6 in lb Mounting and Installation GFK 2847Q...

Page 68: ...x and IC755CxW07CDx attach with M4 screws that are 6 mm 0 24 in or less in length The mounting holes for IC755CxSxxCDx attach with M4 screws that are 8 mm 0 32 in or less in length Torque Range for Mounting M4 Screws Display Unit Torque Range IC755CxS06RDx 0 7 to 0 8 Nm 6 2 to 7 1 in lb IC755CxW07CDx 0 7 to 0 8 Nm 6 2 to 7 1 in lb IC755CxSxxCDx 1 0 to 1 2 Nm 8 9 to 10 6 in lb 75 mm 75 mm 75 mm 2 9...

Page 69: ...el and in a non hazardous location 2 If the QuickPanel Operator Interface is VESA mounted detach from the VESA arm when replacing the battery 3 The battery should only be replaced when the unit is powered off 4 Care should be taken to protect and insert the battery with correct polarity 5 Do not use any metallic item to remove the battery such as screwdrivers knives pliers and so forth 6 Be carefu...

Page 70: ...battery cover by pressing down while sliding outward IC755CxS06RDx Battery Cover Removal 2 Connect the battery harness connector to the header noting keyed orientation Battery Part Number IC755ACCBATT IC755CxS06RDx Battery Harness Connection 3 Verify that the positive red is down and negative black is up 70 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 71: ... the following figure Do not let the harness connector go above the tab Harness Connector Orientation 5 Slide the battery cover into place taking care not to pinch the harness connector Mounting and Installation GFK 2847Q 71 For public disclosure ...

Page 72: ...ery cover by pressing down while sliding outward IC755CxW07CDx Battery Cover Removal 2 Connect the battery harness connector to the header noting keyed orientation Battery Part Number IC755ACCBATT Battery Harness Connection 3 Verify that the positive red connection is down and the negative black connection is up 72 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 73: ... the following figure Do not let the harness connector go above the tab Harness Connector Orientation 5 Slide the battery cover into place taking care not to pinch the harness connector Mounting and Installation GFK 2847Q 73 For public disclosure ...

Page 74: ...ith GE battery part number IC755ACCBATTNL 1 Remove the screws quantity 7 from the back cover IC755CxSxxCDx Screw Locations Back Cover 2 Gently press on either side tab to release the back cover Side Tab for Cover Release 3 Lift up and remove the back cover 74 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 75: ...mber IC755ACCBATTNL IC755CxSxxCDx Battery 4 Gently remove the coin battery and replace with a new one noting the polarity of the battery 5 Replace the battery cover and tighten all screws to 0 5 Nm 4 4 in lb Mounting and Installation GFK 2847Q 75 For public disclosure ...

Page 76: ...pped with 10Base T 100 Base TX Ethernet port s Connect an Ethernet network cable unshielded twisted pair CAT 5 to the unit through the RJ 45 connector s on the bottom of the enclosure LED indicators on the port indicate channel status The port can be accessed by Windows Embedded Compact 7 network communications or by your application 5 7 2 1 Ethernet Port Details Interface Ethernet 10BASE T 100BAS...

Page 77: ... be a DHCP server on the connected network for a valid IP address to be assigned Contact your network administrator to ensure correct DHCP server configuration Manual Method Specify the numeric addresses obtained from your network administrator for the QuickPanel IP Address Subnet Mask and Default Gateway if applicable Note Run the Backup utility to save the settings Mounting and Installation GFK ...

Page 78: ...rial cable to the mating connector while noting signal orientation and tighten the screw clamps The torque for the attaching screws is 0 3 Nm 2 66 in lb Connectors Euro Terminal Tyco Electronics 284539 5 Mating Connectors Tyco Electronics 284510 5 Serial Port COM1 Details Interface RS 232 COM1 Pin Details Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND Pin 1 Pin 5 IC755CxS06RDx Serial Port COM1 Pin...

Page 79: ...able to the mating connector while noting signal orientation and tighten the screw clamps The torque for the attaching screws is 0 3 Nm 2 66 in lb Serial Port COM1 Details Interface x1 RS 232 Connectors Euro Terminal Tyco Electronics 284539 5 Mating Connector Tyco Electronics 284510 5 COM1 Pin Details Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND Pin 1 Pin 5 IC755CxW07CDx Serial Port COM1 Pin out...

Page 80: ...more Secure the serial cable to the mating connector while noting signal orientation and tighten the screw clamps The torque for the attaching screws is 0 3 Nm 2 66 in lb Connectors Euro Terminal Tyco Electronics 284539 5 Mating Connectors Tyco Electronics 284510 5 Serial Port COM1 Details Interface RS 232C COM1 Pin Details Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND COM1 COM2 Pin 1 Pin 5 IC755...

Page 81: ...ls Interface RS 232C 485 default is RS 485 Half duplex COM2 Pin Details Pin RS 232C RS 485 Signal Name Signal Name Full duplex Signal Name Half duplex 1 TXD TXD DATA 2 RXD TXD DATA 3 RTS RXD DATA 4 CTS RXD DATA 5 SGND SG SG Full duplex RS 485 is backwards compatible to RS 422 mode Pins 1 3 and 2 4 are connected internally Pin 1 Pin 5 COM2 COM1 IC755CxSxxCDx Serial Port COM2 Pin out Mounting and In...

Page 82: ...OFF DIP SW Bit ON OFF SW2 1 OFF SW4 1 ON 2 OFF 2 ON 3 OFF 3 OFF 4 OFF 4 OFF 5 ON 5 ON 6 ON 6 ON 7 OFF 7 OFF 8 ON 8 OFF SW3 1 OFF SW5 1 OFF 2 ON 2 OFF 3 OFF 3 OFF 4 OFF 4 OFF Example of Half duplex RS 485 Mode Connection 82 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 83: ...SW Bit ON OFF DIPSW Bit ON OFF SW2 1 OFF SW4 1 ON 2 OFF 2 ON 3 ON 3 ON 4 OFF 4 ON 5 ON 5 ON 6 ON 6 ON 7 OFF 7 OFF 8 ON 8 OFF SW3 1 OFF SW5 1 OFF 2 ON 2 OFF 3 OFF 3 OFF 4 ON 4 OFF Mounting and Installation GFK 2847Q 83 For public disclosure ...

Page 84: ... require installation of the custom driver software Interface USB 2 0 Number of Ports Two Connectors Type A connector Maximum Supply Current 0 5 A per port Pin Signal Name Pin out 1 USB_VCC 2 USB_D 3 USB_D 4 USB_GND 5 7 4 2 USB Device Port Details for IC755CxS06RDx IC755CxW07CDx and IC755CxSxxCDx The USB device port allows the QuickPanel Operator Interface to be used as Slave device Interface USB ...

Page 85: ...d accordingly 5 7 4 4 Wi Fi Support for All Models Using Adapters Recommended USB wifi adapters based on the Ralink chipset are as follows RT 2070 RT 2870 RT 3070 RT 3071 RT 3072 5 7 5 Audio LINE OUT Details for IC755CxS06RDx IC755CxW07CDx and IC755CxSxxCDx Interface LINE OUT stereo Number of Ports One Connectors φ3 5 mm jack Maximum output level 1 Vrms Pin Signal Name Pin out 1 GND 1 2 3 2 Lineou...

Page 86: ...SD slot is not supported on the 6 display unit IC755CxS06RDx Connectors SD card slot push in push out method Card support SD SDHC memory card Maximum capacity 32 GB Note During insertion observe the orientation of the SD card as displayed in the following figures IC755CxS06RDx SD Card Location IC755CxW07CDx SD Card Location 86 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosu...

Page 87: ... IC755CxSxxCDx SD Card Location Mounting and Installation GFK 2847Q 87 For public disclosure ...

Page 88: ...Notes 88 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 89: ...reen with any hard materials such as a screwdriver This could damage the touchscreen display Note IC755CxS06RDx 6 display is an Analog Resistive touch display that does not support two point touch capability Single point gestures such as swipe pan and double tap are supported 6 1 1 Display Brightness Adjustment To adjust the brightness of the display 1 Open the QuickPanel Setup Tool and select the...

Page 90: ...ay Properties window 2 Set the backlight to automatically turn off in a specific amount of time Select Automatically turn off the backlight From the drop down menu select a time between 15 sec to 2 hr 3 Tap OK to exit the QuickPanel Setup Tool 4 Run the Backup Utility to save the settings 90 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 91: ...uchPanel tab 3 Select Recalibrate Touch Screen 4 Select Recalibrate Touch Sensor Note During IC755CxS06RDx or IC755CxW07CDx touchscreen sensor re calibration the user is prompted to activate a switch located in the battery compartment This is not applicable to any other display units 5 Remove the battery cover and press the switch Battery Cover Switch Touchscreen Sensor Calibration Switch 6 Replac...

Page 92: ...to the unit using the USB cable 6 2 2 Soft Input Panel The Soft Input Panel SIP is a touchscreen keyboard that may be used in place of a standard hardware keyboard An icon in the system tray enables the user to view or hide the SIP To show or hide the SIP from the system tray located on the task bar tap the icon and select Hide Input Panel Note When visible the SIP can be moved around the screen b...

Page 93: ...rinting performance select draft mode and portrait orientation and disable color for print settings These settings also minimize the amount of memory needed to print a document The built in driver has a document spooling function to improve GUI performance This spooler supports only one document at a time However on an Ethernet connected printer the print server usually supports multiple documents...

Page 94: ... to make more room for one or the other depending on specific application needs For example if an application is short of memory alter the DRAM memory allocation from the System Properties window Caution Setting the Program Memory too low may prevent additional applications from starting or may cause currently running applications to fail due to lack of memory Setting the Storage Memory too low ma...

Page 95: ...each area is displayed in the window The blue slider bar indicates the current amount of unallocated SDRAM and determines the boundaries within which the slider can move System Memory Slider Bar Note Storage memory is limited to a maximum of 128 MB Using the slider bar to increase storage memory will provide more RAM based storage in the folder Object Store 3 Tap OK to apply the new setting 4 Run ...

Page 96: ...Notes 96 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 97: ...ite and working with Secomea team to enable this functionality To access the Secomea Configuration tool and enable the QuickPanel on the Secomea network 1 From the QuickPanel Start menu select Programs to display the Secomea Configuration tool window 2 Enable the QuickPanel device on the Secomea network Select Enable Remote Management and enter the values provided to you by the Secomea team Note T...

Page 98: ...omea s Industry solution The GateManager M2M Server operates as a termination point for all LinkManagers and SiteManagers All connections and the encrypted traffic between LinkManagers and devices controlled by SiteManagers are handled by the GateManager where all events are also logged Note The GateManager is typically offered as a service hosted by Secomea Users will receive an isolated domain o...

Page 99: ...Secomea Products used with QuickPanel in Application Secomea Security Optional GFK 2847Q 99 For public disclosure ...

Page 100: ...Notes 100 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 101: ...1 UL61010 2 201 CSA C22 2 No 142 M1987 CSA 61010 1 CSA 61010 2 201 ISA 12 12 01 standard and CSA C22 2 No 213 M1987 Explosive Atmospheres Directive European Safety for Hazardous Areas Equipment Group II Category 3 Gas Groups IIC Dust Group IIIC Protection string II 3 G Ex nA IIC T4 Gc II 3 D Ex tc lllC T100 C 212 F Dc Tamb 0 to 55 C 32 to 131 F Certification in accordance with the ATEX Directive 9...

Page 102: ...its 1 The equipment shall only be used in an area of at least pollution degree 2 as defined in IEC 60664 1 Note Pollution degree 2 can be achieved when the installation is in a controlled environment with suitably controlled condensation or airborne pollution 2 The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP 54 in accordance with IEC 60079 0 3 Tran...

Page 103: ...ly with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interfere...

Page 104: ... Shielding USB cables Limiting RS 232 cables to 15 m 49 2 ft in length Using Audio ports only during operational maintenance Although these considerations were deliberated during testing actual EMC environments vary greatly Therefore these considerations may not be necessary Likewise additional measures such as filtering wire separation and cable routing may need to be considered to ensure intende...

Page 105: ...pacitive Screen 12 24 V dc Powered IC755ACC10GAS QuickPanel 10 Replacement Gasket IC755ACC10MNT QuickPanel 10 Accessory Kit Replacement Mounting Clips Power and Serial Port Connectors IC755ACC10PRO QuickPanel 10 Replacement Screen Protectors Qty 3 IC755CSS10CDACA QuickPanel 10 with Conformal Coating IC755CSS12CDx QuickPanel 12 Color TFT with Multi touch Projected Capacitive Screen 12 24 V dc Power...

Page 106: ...Notes 106 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 107: ...entation and tighten the screw clamps The torque for the attaching screws is 0 3 Nm 2 66 in lb Interface x1 RS 232 x1 RS 232 485 default is RS 485 Connectors Euro Terminal Tyco Electronics 1 284539 0 Mating Connector Tyco Electronics 1 284510 0 Pin Signal Name Pin out COM1 5 4 3 2 1 5 4 3 2 1 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND COM2 RS 232 485 1 TXD TXD DATA 2 RXD TXD DATA 3 RTS RXD DATA 4 CTS RXD DATA...

Page 108: ...Notes 108 GFK 2847Q QuickPanel Operator Interface User Manual For public disclosure ...

Page 109: ...Operation LED 23 F Firmware Updates 60 Firmware Upgrade 30 Flash devices 27 FTP with removable Flash devices 27 FTP Server 27 H HTTP Server 28 I Installation 61 battery 69 guidelines 101 protective sheet 61 Installing panel mounting 63 IP Address 77 K Keyboard 92 external 92 SIP 92 L LED Indicators Operation Status 23 LEDs 23 Ethernet Port Operation LED 23 M Machine Edition 26 updating a project 2...

Page 110: ... Secomea Products 98 Serial and Ethernet USB Adapters 85 Serial Port 78 IC755CxS12CDA 80 IC755CxS15CDx 107 Serial Port Details IC755CxS06RDx 78 IC755CxW07CDx 79 Set Current Time 41 Setup basic 57 runtime 59 Shutdown 60 Soft Input Panel 92 Software 25 Specifications 10 Environmental 15 Physical 10 Startup 58 Store Manager 25 T Touchscreen calibration 91 display 89 U Universal Serial Bus USB Ports 8...

Page 111: ......

Page 112: ...Automation Controls from GE 1 800 433 2682 1 434 978 5100 www geautomation com GFK 2847Q For public disclosure ...

Reviews: