Preparación para la instalación

AC

CESORIOS 

DE CONDUCT

OS

Utilice un conducto 

de 3-1/4" x 10". 

Puede conectarse 

con un conducto 

de 6".

  

 

 

 

Longitud

 Pieza 

de 

 

Longitud 

Cantidad Equiv

alente

 Conducto 

Dimensiones 

Equivalente* 

Utilizada T

otal

  

 

pie

 

 

Redondo y 

(por longitud 

 

 

recto de 6" 

de pie)

  

 

pie

 

 

Recto de 

(por longitud

 

 

3-1/4" x 10" 

de pie)

  

6"

 

 

Codo de 90° 

12 pies

  

6"

 

 

Codo de 45° 

7 pies

 

 

3-1⁄4" x 10"

 

 

Codo de 90° 

14 pies

 

 

3-1⁄4" x 10"

 

 

Codo de 45° 

8 pies

 

 

3-1⁄4" x 10"

 

 

Codo plano de 90° 

33 pies

 

 

Redondo de 6" 

  

transición 

 

 

de 3-1⁄4" x 10" 

2 pies

  

Redondo 

de 

 

 

3-1⁄4" x 10" a  

 

 

transición de 6" 

2 pies

 

 

Redondo de 6" 

  

transición 

 

 

de 3-1⁄4" x 10"

 

 

Codo de 90° 

4 pies

 

 

3-1⁄4" x 10" a 

  

transición 

 

 

redondo de 6" 

 

 

Codo de 90° 

4 pies

 

 

Cubierta de par

ed 

 

 

redonda de 6" con

 

 

regulador de tir

24 pies

 

 

Cubierta de par

ed 

 

 

de 3-1/4" x 10" con

 

 

regulador de tir

24 pies

 

 

Casquete de techo 

 

 

redondo de 6" 

33 pies

Recorrido total 

de los conductos 

Utilice esta tabla para 

calcular las longitudes 

máximas permitidas 

para recorridos de 

conductos hacia el 

exterior. 

NOTA

¡No supere las 

longitudes equivalentes 

máximas permitidas!

Ventilación de 

corriente descendent

e:

Longitud equivalent

máxima de 150’

Conductos fl

 exibles:

Si se utilizan conductos 

fl  exibles de metal, todos 

los valor

es equivalentes 

en pies de la tabla 

deben duplicarse. El 

conducto fl  exible 

de 

metal debe ser recto y 

liso y debe extenderse 

lo máximo posible. 

NO USE conductos 

fl  exibles de plástico

*Longitud real del conducto recto más equivalente de accesorio 

  de conducto. La longitud equivalente de las piezas de conductos 

  se encuentra basada en pruebas reales realizadas por el grupo 

  de Ingeniería de Evaluación de GE y refl  ejan los requisitos para 

  un buen desempeño de ventilación con cualquier estufa de 

  corriente descendente.

NOTA

:

 Cualquier 

sistema de ventilación 

doméstico, como 

una estufa con un 

mecanismo de escape 

de corriente 

descendente, puede 

interrumpir el fl  ujo 

adecuado de aire 

de combustión y de 

escape requerido para 

chimeneas, hornos 

a gas, calentadores 

de agua a gas y otros 

sistemas de ventilación 

natural. Para minimizar 

las posibilidades de 

interrupción de tales 

sistemas de ventilación 

natural, siga las pautas 

y normas de seguridad 

del fabricante del 

equipamiento de 

calefacción, tales como 

las publicadas por 

NFPA y ASHRAE.

Summary of Contents for PVB37

Page 1: ...1 Installation Instructions Downdraft Vent Systems PVB37 PVB67 PVB94 PVB98 ZVB30 ZVB36 31 10728 09 09 JR...

Page 2: ...luding fire rated construction CAUTION To reduce the risk of fire and to properly exhaust air be sure to duct air outdoors Do not vent exhaust air into spaces within walls or ceilings or into attics c...

Page 3: ...tep 2 Install the Ductwork 11 Step 3 Install Control Switch 12 Step 4 Connect Power 13 Step 5 Install Filters Check Operation 13 Cleaning 13 PRODUCT DIMENSIONS A B 30 Models 30 28 5 16 36 Models 36 33...

Page 4: ...binet illustration Check to be sure the interior cabinet depth will house the cooktop burner box the vent and the cutout clearance from the front 4 When countertop and cabinet depth present a problem...

Page 5: ...XCEPTION Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance Working areas adjacent to the cooktop s...

Page 6: ...ure that adequate flat countertop surface is available Draw lines on the countertop to follow as a cutting guide Make sure sides of the opening are parallel and rear and front cuts are exactly perpend...

Page 7: ...arpenter s square Ductwork to suit the installation REMOVE PACKAGING Remove the shipping materials and the carton set carton aside The carton can be used as a pad when changing or adjusting vent direc...

Page 8: ...plug with this appliance Follow National Electrical Code or prevailing local codes and ordinances This downdraft vent must be supplied with 120V 60 Hz and connected to an individual properly grounded...

Page 9: ...er to the mounting plate assembly Retain screws Remove blower assembly turn it over to access the 4 nuts holding the blower to the mounting plate Remove the nuts IMPORTANT Do not lift motor by the pow...

Page 10: ...t 150 maximum equivalent length Flexible ducting If flexible metal ducting is used all the equivalent feet values in the table should be doubled The flexible metal duct should be straight and smooth a...

Page 11: ...ightest duct run possible For satisfactory performance the duct run should not exceed 150 ft or its equivalent length when bends or various fittings are used Refer to the table of equivalent lengths t...

Page 12: ...ng to cover any gaps Connect Control Switch to Remote Harness Thread the remote harness through the 1 2 dia hole and attach the harness connector to the remote connector Remove the paper backing on th...

Page 13: ...o the retainers and close the vent Press the Fan Speed HIGHER pad to start the blower Adjust the blower by pressing HIGHER or LOWER The blower if left on will automatically turn off when the vent is l...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...described in this book safety glasses or goggles should be worn NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to c...

Page 17: ...este libro deben utilizarse gafas o lentes de seguridad NOTA La mejora de los productos es un esfuerzo continuo para General Electric Por lo tanto los materiales la apariencia y las especi caciones p...

Page 18: ...15 Notas...

Page 19: ...14 Notas...

Page 20: ...ci n Presione el bot n HIGHER m s alta de la velocidad del ventilador para accionarlo Ajuste la velocidad del ventilador presionando HIGHER m s alta o LOWER m s baja Si se lo deja encendido el ventila...

Page 21: ...al para cubrir ori cios Conecte el interruptor de control al arn s remoto Pase el arn s remoto a trav s del ori cio de 1 2 de di metro y sujete el conector del arn s al conector remoto Quite el recubr...

Page 22: ...ductos m s recto posible Cuando se utilizan curvas y varios accesorios y para un desempe o satisfactorio el recorrido de los conductos no debe superar los 150 pies o su longitud equivalente Consulte l...

Page 23: ...des equivalentes m ximas permitidas Ventilaci n de corriente descendente Longitud equivalente m xima de 150 Conductos exibles Si se utilizan conductos exibles de metal todos los valores equivalentes e...

Page 24: ...illos Quite el montaje del ventilador g relo para poder acceder a las 4 tuercas que sostienen el ventilador a la placa de montaje Quite las tuercas IMPORTANTE No levante el motor tom ndolo del cable d...

Page 25: ...descendente debe contar con un suministro de 120V 60Hz y debe estar conectada a un circuito derivado individual con adecuada conexi n a tierra y debe contar con la protecci n de un interruptor de cir...

Page 26: ...rande Sierra de vaiv n Regla de carpintero Conductos para toda la instalaci n QUITE EL ENVOLTORIO Quite los materiales de env o y la caja separe la caja La caja puede usarse como una almohadilla al ca...

Page 27: ...de mostrador de encimera Trace l neas sobre el mostrador de encimera para usar como una gu a de corte Veri que que los lados de la abertura est n paralelos y que los cortes trasero y frontal sean exa...

Page 28: ...de cocci n sobre la estufa deber cumplir con las instrucciones de instalaci n incluidas con el aparato Las reas de trabajo adyacentes a la estufa deben contar con un espacio m nimo de 18 entre el most...

Page 29: ...el gabinete presentan un problema consulte la secci n Soluciones creativas 5 Lea este libro por completo para plani car detalladamente la ubicaci n de la instalaci n los espacios y los requisitos de l...

Page 30: ...11 Paso 2 Instale los conductos 11 Paso 3 Instale el interruptor de control 12 Paso 4 Conecte la energ a 13 Paso 5 Instale los ltros controle el funcionamiento 13 Limpieza 13 DIMENSIONES DEL PRODUCTO...

Page 31: ...ncendios PRECAUCI N Para reducir el riesgo de incendio y para eliminar el aire de escape correctamente aseg rese de dirigir el aire del conducto hacia el exterior No dirija el aire de escape hacia esp...

Page 32: ...1 Instrucciones de instalaci n Sistemas de ventilaci n de corriente descendente PVB37 PVB67 PVB94 PVB98 ZVB30 ZVB36 31 10728 09 09 JR...

Reviews: