Page 30
IX. FAILURE DIAGNOSIS
Repair the contacting point.
The contacting point being poor?
Is the circuit of compressor coil
normal?
Inspection of the
frosted cooler
Poorly defrosted
Refer to the method of non-
defrost
Ice beads or serious frost formed in the
cooler chamber
Freon leakage
Inspection of freon
leakage
Non-defrost
Poor location be repaired.
Replace the compressor, drying
filter. Clean the freon circuit.
Clogged by impurities
Replace the clogged parts.
Replace the drying filter. Clean
the freon circuit.
Yes
Replace the compressor and
drying filter
Abnormal
No
* Remove the pin from the connecting point and
check if it has turned into black.
* Check the circuit of main coil, auxiliary coil and
resistance value.
Check the leakage
location
* When the inner side of compressor is
too dirty, it must be replaced.
Defective freon circuit
Freon circuit
clogged
No freon leakage
Poor compression of
the compressor
Replace the compressor, drying
filter
Clean the freon circuit
The lower pressure tube of
compressor fails to suck the air.
Yes
Summary of Contents for PTV15SAMR
Page 53: ...Page53 XII PART LIST AND EXPLODED VIEW PTV15SAMR PTU427SAMR PTQ440SAMR PTG440SAMR...
Page 54: ...Page54 XII PART LIST AND EXPLODED VIEW PTV15SAMR PTU427SAMR PTQ440SAMR PTG440SAMR...
Page 61: ...Page61 XII PART LIST AND EXPLODED VIEW PTV16SAMR PTU463SAMR PTQ470SAMR PTG470SAMR...
Page 62: ...Page62 XII PART LIST AND EXPLODED VIEW PTV16SAMR PTU463SAMR PTQ470SAMR PTG470SAMR...
Page 70: ...Page70 XII PART LIST AND EXPLODED VIEW PTV19SAMR PTU527SAMR PTQ530SAMR PTG530SAMR...
Page 71: ...Page71 XII PART LIST AND EXPLODED VIEW PTV19SAMR PTU527SAMR PTQ530SAMR PTG530SAMR...
Page 78: ...Page78 XII PART LIST AND EXPLODED VIEW PTV20SAMR PTU565SAMR PTQ570SAMR PTG570SANR...
Page 79: ...Page79 XII PART LIST AND EXPLODED VIEW PTV20SAMR PTU565SAMR PTQ570SAMR PTG570SANR...