Page 14
III. SERVICE GUIDE
3.8
REPLACEMENT OF PTC & OLP
OVERLOAD RELAY
3.8.1
Remove the compressor cover.
3.8.2
Remove electric box clamp.
3.8.3
Remove electric box.
3.8.4
Remove PTC & OLP and replace PTC &
OLP.
electric box
start relay
OLP overload relay
3.9
HOW TO CLEAN DRAIN PIPE
3.9.1
Remove drain hole cover.
3.9.2
Remove drain connector.
3.9.3
Clean connector & drain pipe.
drain connector
Dismounting and Cleaning of Drainage Pipe
Control box
Drainage hole cover
Drainage pipe
Before opening the box
After opening the box
3.9.4
Water Drainage
i.
The water drainage adapter in the
drawer should be cleaned every 6
months to 1 year to keep it from being
obstructed. This avoids poor drainage
and refrigeration.
ii.
The water drained from the refrigerator
is drained into the evaporation pan
from the drainage system.
iii. Water in the evaporation pan shall be
duly evaporated by the radiator. There
is no need to remove it.
iv.
After some time, dust or impurity
builds up in the evaporation pan and
produces odor. This should be
cleaned once a month.
Summary of Contents for PTV15SAMR
Page 53: ...Page53 XII PART LIST AND EXPLODED VIEW PTV15SAMR PTU427SAMR PTQ440SAMR PTG440SAMR...
Page 54: ...Page54 XII PART LIST AND EXPLODED VIEW PTV15SAMR PTU427SAMR PTQ440SAMR PTG440SAMR...
Page 61: ...Page61 XII PART LIST AND EXPLODED VIEW PTV16SAMR PTU463SAMR PTQ470SAMR PTG470SAMR...
Page 62: ...Page62 XII PART LIST AND EXPLODED VIEW PTV16SAMR PTU463SAMR PTQ470SAMR PTG470SAMR...
Page 70: ...Page70 XII PART LIST AND EXPLODED VIEW PTV19SAMR PTU527SAMR PTQ530SAMR PTG530SAMR...
Page 71: ...Page71 XII PART LIST AND EXPLODED VIEW PTV19SAMR PTU527SAMR PTQ530SAMR PTG530SAMR...
Page 78: ...Page78 XII PART LIST AND EXPLODED VIEW PTV20SAMR PTU565SAMR PTQ570SAMR PTG570SANR...
Page 79: ...Page79 XII PART LIST AND EXPLODED VIEW PTV20SAMR PTU565SAMR PTQ570SAMR PTG570SANR...