– 34
11. Loosen the hex-head screws that hold the
evaporator in place. Note locations of the
foam blocks at sides of old evaporator. These
are needed for proper airfl ow. Remove the
foam blocks and save for new evaporator
installation. Remove old evaporator.
Fig. 1
Fig. 2
12. Modify replacement evaporator to accept the
5
/
16
-in. fresh food evaporator jumper.
Modify
Here
13. Install the new evaporator and tighten all
mounting screws.
14. Connect tubes between top of accumulator
and suction line. Connect tubes between
fresh food evaporator and freezer evaporator
(right side). Insert the capillary tube.
15. Check that the thermal paste is still on the
suction line where it enters the rear wall of the
freezer. If not, apply paste. In addition, apply
thermal paste around epoxy joints on the new
evaporator to prevent the heat from damaging
joint integrity.
16. Protect the freezer fl oor from molten
solder during brazing. Braze suction line to
accumulator on new evaporator. Angle torch
so that fl ame is directed away from rear wall
when brazing.
17. Move the brazing shield behind the capillary
joint and braze the capillary tube.
FF
Evaporator
Jumper
FZ
Evaporator
Inlet
Jumper
Top of
Accumulator
Brazing Shield
Suctio
n
Tube
Line
Cut
Here
FF
Evaporator
Outlet
Remove
Screw
Capillary
Tube
Cut
Here
2"
Loosen Hex-
Head Screws
2"
Heat
Here
Summary of Contents for PSH23PGR Series
Page 15: ... 15 Freezer Section Cooling Condenser Fan Running Fresh Food Fan Off Freezer Fan Running ...
Page 44: ... 44 Illustrated Parts ...
Page 45: ... 45 ...
Page 46: ... 46 ...
Page 47: ... 47 ...
Page 48: ... 48 ...
Page 49: ... 49 ...
Page 50: ... 50 ...
Page 51: ... 51 ...
Page 52: ... 52 ...
Page 53: ... 53 ...