ADAPTING BLOWER FOR
RECIRCULATION
NOTE:
The exhaust adaptor with damper is not needed
for recirculating models. You may want to save them for
possible future use.
Remove and save screws that hold the blower plate
to the oven.
Slide the blower plate from under its retaining flange
and lift it off. Remove and save screw that holds the
blower motor to oven.
Carefully pull out the blower unit. The wires will
extend far enough to allow you to adjust the
blower unit.
3
2
1
C3
20
Installation Instructions
Retaining Flange
Roll the blower unit 90° so that fan blade openings
are facing toward the front of the oven.
NOTE:
Make sure wires remain routed in the grooves of
the motor frame.
Place the blower unit back into the opening.
CAUTION:
Do not pull or stretch the blower
unit wiring. Make sure the wires are not pinched.
5
4
BEFORE: Fan Blade
Openings Facing Up
Roll
AFTER: Fan Blade
Openings Facing
Forward
Retaining
Flange
Blower Plate
Back of Oven
Blower Plate Screws
Blower Motor
Screw
Blower Plate