– 55 –
8. Mark the location, then disconnect the black L1,
blue L2, and ground wire connections on the
fi
lter board.
9. Disconnect the thermal cut-out and
fi
lter-to-
bridge wire harnesses.
10. Disconnect the LINbus connectors. (See
LINbus
Connectors
.)
11. Using a
fl
at blade screwdriver, carefully press
the 2 left side large tabs away from the
fi
lter
board. Lift the
fi
lter board and pull the
fi
lter
board away from the smaller tab on the right
side of the module base.
Tab
Tab
Tab
Arrows indicate disconnect locations
Filter Board
To remove the main
fi
lter board:
Remove the induction module. (See
1.
Induction
Module
.)
Place the module component side down on a
2.
protective surface.
Note the location of the black, red, and green
3.
wires and the 2 jumper blades connected to the
fi
lter board power terminals.
Remove the T-20 Torx screw and the wire
4.
retainer from the module.
Using a T-20 Torx or a
fl
at blade screwdriver,
5.
loosen the 5 terminal screws, then remove the
black, red, and green wires, and the 2 jumper
blades.
Tighten the terminal screws.
6.
7. Place the module component side up on a
protective surface.
Jumper
Blade
Jumper
Blade
Wire Retainer
Retainer