Handling and Installation 17
NOTE
S1 position 8 should be set in the
ON
position only when a flash update of the control logic has
failed. After a successful flash update of the control logic, S1 position 8 should be set in the
OFF
position.
Table 1-1 Example Node ID Switch S2 RFM-5565
S2
Position 8
S2
Position 7
S2
Position 6
S2
Position 5
S2
Position 4
S2
Position 3
S2
Position 2
S2
Position 1
Node ID
Hex (Dec.)
ON
ON
ON
ON
ON
ON
ON
ON
$FF (255)
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
$80 (128)
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
$40 (64)
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
$20 (32)
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
$10 (16)
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
$8 (8)
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
$4 (4)
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
$2 (2)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
$1 (1)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
$0 (0)
Factory Default
: S2 positions 1 through 8 OFF
Table 1-2 Switch S1 Configuration RFM-5565
Position 1 OFF (non-redundant mode)
Position 1 ON (redundant mode)
Position 2 OFF (higher performance achievable)
Position 2 ON (low network usage)
Position 5 OFF (disables Rogue Master 0)
Position 5 ON (enables Rogue Master 0)
Position 6 OFF (disables Rogue Master 1)
Position 6 ON (enables Rogue Master 1)
Position 8 OFF (most recent control logic)
Position 8 ON (original factory control logic)
Factory Defaults
Positions 1-8 OFF
PCI Window Size S1 Position 3
S1 Position 4
Default
Off
Off
64 MByte
On
Off
16 MByte
Off
On
2 MByte
On
On