background image

 

PACSystems RXi Box IPC-XP Hardware Reference Manual

                                                                                                               

GFK-2990      46

 

Internal 

4.3.6

 

VGA Interface (RXM1x2 only) 

A VGA port provides signals for connecting a suitable monitor. 

 

Figure 23: VGA interface 

Name 

 

RED1 

GREEN1 

BLUE1 

 

GND 

GND 

GND 

GND 

VGA_VCC 1) 

GND 

10 

 

11 

VGA1_DDCData 

12 

VGA1_HSYNC 

13 

VGA1_VSYNC 

14 

VGA1_DDCClock 

15 

Table 11: VGA 

1) VGA_VCC is fused with 2 A, but for normal operation don’t exceed 1 A at this pin. 

 

 

Summary of Contents for PACSystems RXi-XP IPC

Page 1: ...Internal GFK 2990 PACSystems RXi Box IPC XP Hardware Reference Manual Edition 3 0 HWRMRXiXP ...

Page 2: ...oved power consumption for new system configurations updated CFAST Slot Type I specified 2013 11 25 PS 1 0 First release footer link to docx file removed 2014 02 04 PS 3 0 Including RXMxx0 RXM1x2 sheet metal cabinet and PERC01 02 riser cards configurations weight table corrected NVRAM section corrected preferred mounting orientation added minor typos removed more configurations for power consumpti...

Page 3: ...cations to this unit not expressly approved by GE Intelligent Platforms could void the user s authority to operate the equipment All computer code and software contained in this document is licensed to be used only in connection with a GE Intelligent Platforms hardware product Even if this code or software is merged with any other code or software program it remains subject to the terms and condit...

Page 4: ...License LGPL See chapter 9 Appendix In accordance with LGPLv2 1 licensing you may obtain the corresponding source code from GE Intelligent Platforms for a period of three years after our last shipment of this product which will be no earlier than 2017 Please include the model and serial number of the product and direct requests to oss ge com ESD EMI issues ESD Electro Static Discharge and EMI Elec...

Page 5: ...anies or operated on company premises factory floor laboratory do not need CE certification CE certification can only be granted to complete and operational systems Boards or subsystems which cannot provide a useful function on their own do not need CE certification GE Intelligent Platforms designs and tests all their products for EMI EMC conformance Products manufactured by GE Intelligent Platfor...

Page 6: ...rmany US GE Intelligent Platforms GmbH Co KG Memminger Str 14 86159 Augsburg Germany GE Intelligent Platforms Inc 2500 Austin Drive Charlottesville VA 22911 U S A Phone 49 821 5034 0 Fax 49 821 5034 119 Phone 1 800 322 3616 E Mail sales augsburg ip ge com Web http www ge ip com GE Intelligent Platforms on the Web http www ge ip com For contact and other information service warranty support etc see...

Page 7: ...edom in meeting form fit function requirements For all these reasons the COM methodology has gained much popularity with OEMs in the embedded industry The CEC02 CEC04 Carrier boards are based on the PICMG COM Express Module Base Specification The RXi Box IPC XP is based on industrial grade housing for the Module and Carrier components Chapter 1 is the introduction Chapter 2 describes unpacking and...

Page 8: ...set Notes warning symbols and cautions call attention to essential information Product Properties Certification This product is certified according to CE EN IEC 60950 1 EN IEC 61131 2 For more information about certifications please refer to chapter 6 Specification Altitude Altitude air pressure and ambient temperature influence the thermal operation of the components described in this manual They...

Page 9: ...Reference Manual GFK 2990 9 Internal Please see chapter ʹSupport Service and Warranty Informationʹ for further details on repairs and product support For support on the web and product information visit our website at http www ge ip com ...

Page 10: ...Disk Drive 35 3 9 Initial Power On Operation 35 3 10 Entering the UEFI Firmware SETUP 36 3 11 Exchange the Battery 36 4 Hardware 39 4 1 Overview for RXE and RXMxx0 based on the carrier CEC04 39 4 2 Overview for RXM1x2 based on the carrier CEC02 40 4 3 Interfaces 41 4 3 1 LEDs 42 4 3 2 Power Button 43 4 3 3 Reset Button 43 4 3 4 Ethernet Interface Eth1 Eth2 Eth3 Eth4 Eth5 on RXM1x2 Eth1 Eth2 Eth3 4...

Page 11: ...nternal 5 2 ETHERNET 53 5 3 PCIE ports 54 5 4 PCI ROUTING 54 6 Specifications 57 6 1 RXi Box IPC XP Specifications 57 7 Support Service and Warranty 61 7 1 Technical Support 62 7 2 Support on the Web 63 7 3 Warranty 63 7 4 Error Report 64 8 Glossary 65 9 Appendix 67 ...

Page 12: ...le 34 Figure 10 Internal SATA installation vendor is subject to change 35 Figure 11 Removed front panel view at battery 36 Figure 12 Removed battery 37 Figure 13 Retaining clip with battery 37 Figure 14 Hardware Overview 39 Figure 15 Hardware Overview 40 Figure 16 front panel RXE and RXMxx0 41 Figure 17 front panel RXM1x2 41 Figure 18 front panel LEDs 42 Figure 19 Power button 43 Figure 20 Reset b...

Page 13: ...ower LED 44 Table 9 Ethernet LEDs 44 Table 10 Display Port signals 45 Table 11 VGA 46 Table 12 USB port 1 2 47 Table 13 USB port 2 3 48 Table 14 Power Connector 49 Table 15 Serial Ports 51 Table 16 SMBus Devices 53 Table 17 I2C Bus device 53 Table 18 PCI Express Port usage 54 Table 19 PCI Routing 55 Table 20 Environment conditions 57 Table 21 Shock vibration parameters 57 Table 22 Maximum height u...

Page 14: ...PACSystems RXi Box IPC XP Hardware Reference Manual GFK 2990 14 Internal ...

Page 15: ...s Number of USB 3 0 USB 2 0 Number of DisplayPort VGA Number of Serial RS232 RS4xx Cabinet height mm RXE0x0 X CEC04 0 0 5 2 2 1 0 2 0 a 76 RXE2x0 X CEC04 043 0 2 5 2 2 1 0 2 0 a 121 RXE4x0 X CEC04 044 0 4 5 2 2 1 0 2 2 158 RXE5x0 X CEC04 PERC02 2 0 5 2 2 1 0 2 0 a 121 RXE6x0 X CEC04 PERC01 2 2 5 2 2 1 0 2 2 158 RXM0x0 X CEC04 0 0 5 2 2 1 0 2 0 a 117 RXM1x2 X CEC02 1 0 3 0 4 1 1 0 117 RXM2x0 X CEC0...

Page 16: ... Button o Power Button o Display Port o 4x USB A connector 2x are USB 3 0 capable with bCOM6L14 only and 1x internal USB 2 0 o 5x Ethernet connector o 1x CFast Type 1 bay o 4x Status LED The COM Express Carrier CEC02 used in the RXM1x2 provides the following core hardware and firmware resources Support for COM Express Module Type 6 Functions available on internal connectors o Mini PCIe slot half f...

Page 17: ...L14 o Processor Intel Core i7 3555LE Processor 2 5GHz Intel Celeron Processor 1047UE 1 4GHz Intel Core i7 3612QE Processor 2 1GHz o Chipset Intel Chipset PCH QM77 o System Memory One Channel one or two ranks soldered with ECC 2 GB or 4GB DDR3 SDRAM with 1066 or 1600 MHz o UEFI SPI interface UEFI 16 Mbit o LAN One INTEL internal PCI Express Gigabit controller with 82579 external Phy Supports 10Mbps...

Page 18: ...PACSystems RXi Box IPC XP Hardware Reference Manual GFK 2990 18 Internal ...

Page 19: ...ound information necessary prior to using the RXi Box IPC XP Unpacking initial inspection and first time operation of the RXi Box IPC XP are covered Following the procedures given in the chapter are recommended and they will verify proper operation before the product is integrated into your system 2 1 Package Contents Qty Item Purpose 1 RXi Box IPC XP RXi Box Industrial PC XP Table 2 Delivery volu...

Page 20: ...ailable accessories NOTE Please contact the GE Intelligent Platforms sales department or your sales representative for latest information on options and accessories NOTE Accessories are subject to change without notice 2 3 Hot Surface WARNING Hot Surface If the RXi Box IPC XP operates by an enhanced ambient temperature more than 50 C the surface of the housing specially the heat sink can reach a t...

Page 21: ...re that you could ʹzapʹ the board without you knowing it a small discharge imperceptible to the eye and touch can often be enough to damage electronic components Extra caution should be taken in cold and dry weather when static easily builds up Only after ensuring that both you and the surrounding area are protected from ESD carefully remove the board or module from the shipping carton by grasping...

Page 22: ... devices might also have temperature restrictions Keep all original packaging material for future storage or warranty shipments of the board Although the RXi Box IPC XP is carefully packaged to protect it against the rigors of shipping it is still possible that shipping damages can occur Careful inspection of the shipping carton should reveal some information about how the package was handled by t...

Page 23: ...on operations 3 1 Mounting instruction The IPC cooling is designed for wall mounted orientation of the box The orientation of the heat sink fins depends on the order code There are three kinds of fixings possible 3 1 1 Flat wall mounting Clearances flat wall mounting For best heat dissipation observe the minimum clearances from the drawing below Figure 2 Heat dissipation drawing ...

Page 24: ...he wall The mounting plates have 4 drills holes with a diameter of 5 3 mm So the maximum screw diameter cannot be higher than 5 2 mm The head of the screws have to be smaller than 10 mm to pass the hole of the top fixing points of the mounting plate NOTE The mounting plate for 2 slot and 4 slot version will be the same Figure 3 Flat mounting with mounting plates ...

Page 25: ...front lid by opening the 4 screws with a screw driver Torx 20 You will find the 4 holes on the left and right side inside the box red marked on the picture below The thickness of the box is 28 mm at these locations Figure 4 Flat wall mounting through the box illustration Take the distances of the holes and the clearances from the drawing in chapter 9 1 After fixing the IPC with sufficient long scr...

Page 26: ...from the wall side you need drill holes in the wall The positions for the holes can be taken from the drawing below The thread in the housing is a M6 with a usable thread length of 15 mm Choose the screw length so that a minimum of 10 mm thread will be used Use a torque of 3 5 Nm Figure 5 Flat wall mounting through the wall illustration ...

Page 27: ... 27 Internal 3 1 2 Slim Mounting Clearances slim wall mounting For heat dissipation observe the minimum clearances from the drawing below Slim 80 mounting plate ICRXIACCMP01 Slim 70 mounting plate ICRXIACCMP03 Figure 6 Clearances slim wall mounting illustration ...

Page 28: ...wall The mounting plate has 4 drills holes with a diameter of 4 5 mm So the maximal screw diameter cannot be higher than 4 4 mm The head of the screws have to be smaller than 10 mm to pass through the hole of the top fixing points of the mounting plate NOTE The mounting plate for 2 slot and 4 slot version will be the same Figure 7 Slim mounting with mounting plate ...

Page 29: ...if any are correctly configured for your application Mount the RXi Box IPC XP very carefully See also additional advisories below Connect all IO cables Once you are certain that all modules are correctly fitted into the system and all connections have been made properly restore the power 3 3 General advice Please observe all safety procedures to avoid damaging system and protect operators and user...

Page 30: ... Please make sure that you do not have the power supply turned ON while opening the housing for installing add on cards such as PCIe cards or internal SATA drives into the RXi Box IPC XP 3 4 2 Keyboard You should have a USB keyboard for initial system operation of the RXi Box IPC XP Depending on your application this keyboard may be a standard keyboard or one which utilizes membrane switches for h...

Page 31: ... Self Test The following is the procedure of the POST CPU must exit the reset status mode and thereafter be able to execute instructions SPI Flash ROM and NVRAM was readable Checksum must be valid meaning that it must be readable CMOS checksum must be valid meaning that it must be readable CPU must be able to read all forms of memory such as the memory controller memory bus and memory module The f...

Page 32: ...cribed in this chapter is for service technician only PCI Boards and PCI Express Boards are installed into the RXi Box IPC XP as shown by the pictures below for the RXE2x0 All other configurations including RXM are quite similar in this procedure Slot cover empty Slot cover screw removed PCI support_B removed PCI slot bracket removed ...

Page 33: ...Xi Box IPC XP Hardware Reference Manual GFK 2990 33 Internal PCI card bracket inserted into slot PCI card inserted into PCIe connector PCI support_B added PCI cover screw added Figure 8 Installation of a PCIe card ...

Page 34: ... on card ATTENTION The information described in this chapter is for service technician only Mini PCIe cards are installed into the RXi Box IPC XP by as shown Mini PCIe slot full size empty Mini PCIe slot half size empty Insert Mini PCIe module Mounted Mini PCIe module Figure 9 Installation of Mini PCIe module ...

Page 35: ...lid State Drives is recommended Standard rotating disk drives may be used if they withstand the intended temperature range within the RXi Box IPC XP box Figure 10 Internal SATA installation vendor is subject to change 3 9 Initial Power On Operation After a few seconds the RXi Box IPC XP system BIOS banner will be displayed on the screen If you have seen all the on screen messages to this point you...

Page 36: ...elligent Platforms technical support as described in chapter ʹSupport Service and Warranty Informationʹ for further instructions 3 11 Exchange the Battery ATTENTION The information described in this chapter is for service technician only There is danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent to Rayovac BR2032 type Dispose used batteries accordi...

Page 37: ...emoved battery WARNING Use of a different type of battery than that specified here may present a risk of fire or explosion WARNING Battery may explode if mistreated Do not recharge disassemble heat above 100 C or incinerate 4 Install the new battery in the retaining clip with the positive side up Figure 13 Retaining clip with battery ...

Page 38: ...PACSystems RXi Box IPC XP Hardware Reference Manual GFK 2990 38 Internal 5 Remount the top cover on the IPC and tighten the four screws to secure it ...

Page 39: ...hernet MAC PHY i210 10 100 1000 Ethernet MAC PHY i210 Magnetics Riser Connector UART 4 ch x4 PCIe Gen1 x 1 P C I e G e n 1 mini PCI e x1 PCIe Gen1 x1 PCIe Gen1 x1 PCIe Gen1 Opto coupl Transc RS 232 Transc RS 232 Transc RS 422 RS485 Transc RS 422 RS485 Opto coupl Power Conn DB 9 DB 9 DB 9 DB 9 optional optional RJ 45 DP CFast USB USB USB USB Magnetics RJ 45 Magnetics RJ 45 Magnetics RJ 45 Magnetics...

Page 40: ...PACSystems RXi Box IPC XP Hardware Reference Manual GFK 2990 40 Internal 4 2 Overview for RXM1x2 based on the carrier CEC02 Figure 15 Hardware Overview ...

Page 41: ...terfaces Depending on the used carrier two basic variants of the front panel exist Top is always shown the standard panel on a CEC04 Below can be found the panel of the CEC02 used in the RXM1x2 RXE and RXMxx0 Figure 16 front panel RXE and RXMxx0 RXM1x2 Figure 17 front panel RXM1x2 ...

Page 42: ...Power LED Status No hard disk activity off Hard disk activity on SATA or CFlash amber Table 5 Hard disk activity LED Status User Status LED a User Status LED amber by default a On RXM1x2 this LED shows the status of the battery coin cell within the system It lights red when the battery is exhausted After replacement of the battery the red LED must be reset within UEFI SETUP Table 6 User status LED...

Page 43: ...ed for more than 5 seconds forces the RXi Box IPC XP to shut down immediately without operating system support State S5 Soft Off Mode will switch off the CPU core power and hold the RXi Box IPC XP in reset The state S5 is indicated with an amber Power LED At this state it is possible to reactivate the RXi Box IPC XP with a short press of the Power Button The CPU core voltage is switched on and the...

Page 44: ...ration with 100 1000BaseT Name 10 100base Name 1000base TxD LP_DA 1 TxD LP_DA 2 RxD LP_DB 3 NC LP_DC 4 NC LP_DC 5 RxD LP_DB 6 NC LP_DD 7 NC LP_DD 8 Table 8 Front Power LED Two LEDs green and yellow are integrated in each of the RJ45 connector These LEDs indicate the link status and activity of the interface LED Function Right green LED On Off Link is active No link Left yellow LED On blink Off Tx ...

Page 45: ... connecting either a suitable monitor or adaptor to lots of other display standards Figure 22 Display Port Name TxD0 1 3 TxD1 4 6 TxD2 7 9 TxD3 10 12 AUXSEL 13 CLK AUX 15 DAT AUX 17 HTPLG 18 n c 14 DP_VCC a 20 GND 2 5 8 11 16 19 Table 10 Display Port signals a DP_VCC is fused with 2 A but for normal operation don t exceed 1 A at this pin ...

Page 46: ...port provides signals for connecting a suitable monitor Figure 23 VGA interface Name RED1 1 GREEN1 2 BLUE1 3 4 GND 5 GND 6 GND 7 GND 8 VGA_VCC 1 9 GND 10 11 VGA1_DDCData 12 VGA1_HSYNC 13 VGA1_VSYNC 14 VGA1_DDCClock 15 Table 11 VGA 1 VGA_VCC is fused with 2 A but for normal operation don t exceed 1 A at this pin ...

Page 47: ... channels are available at standard USB Type A connectors Each pair of them is fused with 2 A but for normal operation don t exceed 0 5 A per connector Figure 24 USB 2 0 connectors Name FUSE_VCCa 1 USB 2 USB 3 GND 4 Table 12 USB port 1 2 a the FUSE_VCC pin has a 2 A fuse For normal operation don t exceed 0 5A current per connector ...

Page 48: ...Each pair of them is fused with 2 A but for normal operation don t exceed 0 5 A per connector The blue USB connector supports USB 3 0 when used with the bCOM6L14 CPU module Figure 25 USB 3 0 connectors Name FUSE_VCCa 1 USB 2 USB 3 GND 4 SSRX 5 SSRX 6 GND 7 SSTX 8 SSTX 9 Table 13 USB port 3 4 a the FUSE_VCC pin has a 2 A fuse For normal operation don t exceed 0 5A current per connector ...

Page 49: ...wer minus is connected to GND of all connections within the RXi Box IPC XP Therefore when using a power supply with a supply reference to PE ground please connect the 24V to power plus and the GND to power minus NOTE Never use a power supply generating a 24V output if the positive supply is related to PE ground It will be shortened if any external device is connected to the RXi Box IPC XP The powe...

Page 50: ...ting media may be used if they withstand the intended temperature range inside the RXi Box IPC XP The use of Solid State Disk is recommended 4 3 11 CFast Slot On the front of the RXi Box IPC XP there a CFast Type I flash slot is available Standard CFast cards can be used for storage of data or the operating system The device is connected to a standard SATA port of the COM module Figure 27 CFast co...

Page 51: ... D connectors for local terminals or peripheral communication On request a combination of RS232 and RS422 485 is orderable too The 4 slot variant is equipped with four serial ports Serial ports 1 2 are RS232 and serial ports 3 4 are RS422 485 RS232 pin DCD 1 RxD 2 TxD 3 DTR 4 GND 5 DSR 6 RTS 7 CTS 8 RI 9 RS422 485 Rx 1 Rx 2 Tx 3 Tx 4 GND 5 Table 15 Serial Ports 4 3 13 Mini PCIe Slot On the carrier...

Page 52: ... devices 4 4 1 Temperature Sensor Temperature sensors are integrated in the CPU module and on the carrier The sensor on the carrier shows the local ambient temperature within the RXi Box IPC XP The sensors of the CPU and Carrier are programmed to take actions to protect the devices from over heating The CPU temperature sensor has a catastrophic protection which shut down the CPU core voltage if th...

Page 53: ...CIe Clock Buffer on CEC04 DB106 1101 010x PCIe Clock Buffer on CEC02 RXM1x2 LM29245 1001 100x Temperature sensor on bC6L14 via EC controller 24C08 1010 000x SPD on bC6L14 LM95245 0101 001x Temperature sensor on CEC04 Table 16 SMBus Devices Device Address Function 24c512 1010 000x Factory EEprom of bC6L14 24c64 1010 111x Factory EEprom of CEC02 CEC04 Table 17 I2C Bus device 5 2 ETHERNET The Etherne...

Page 54: ...s followed Function Connected to Vendor Device Bus Dev Func On bCOM6L14 Host Bridge internal 8086 0154 0 00 0 PEG PCle Switch 8086 0151 0 01 0 Graphics Internal 8086 0156 0 02 0 USB xHCI Controller 8086 1E31 0 14 0 ME Interface 8086 1E3A 0 16 0 LAN Controller 8086 1502 0 19 0 USB EHCI Controller 2 8086 1E2D 0 1A 0 PCIe 1 Riser card 043 8086 1E10 0 1C 0 PCIe 2 PCIe Serial 8086 1E12 0 1C 1 PCIe 3 Mi...

Page 55: ... Serial 12D8 7954 9 00 0 Mini PCle A 00 0 On Riser card 043 044 RXx2x0 RXx4x0 PCIe to PCI bridge PCI Slots 12D8 E113 7 00 0 NVSRAM 1533 3AD2 8 05 0 PCI Slot 1 8 06 0 PCI Slot 2 8 07 0 PCI Slot 3 8 08 0 PCI Slot 4 8 09 0 Riser card PERC01 02 RXx6x0 RXx5x0 PCIe Switch PCIe Slots 10B5 8606 7 00 0 PCIe Slot 1 8 00 0 PCIe Slot 2 9 00 0 PCIe to PCI bridge PCI Slots 12D8 E113 A 00 0 NVSRAM 1533 3AD2 B 05...

Page 56: ...PACSystems RXi Box IPC XP Hardware Reference Manual GFK 2990 56 Internal ...

Page 57: ...XxxxxE RXxxxxN 17W CPU RXxxxxF 25W CPU RXxxxxQ 35W CPU 70 C 60 C 55 C 50 C Low Temperature Storage Operating 40 C 0 C Relative Humidity Storage Operating up to 95 non condensing a For more temperature information and extended temperature range please ask our support team Table 20 Environment conditions The RXi Box IPC XP is designed to meet these shock and vibration values Level A Vibration Spectr...

Page 58: ...A Intel Celeron 1047UE 1 4GHz 4GB RXx6N0F0G134A Intel Core i7 3555LE 2 5GHz 4GB RXx2N0Q0F102A Intel Core i7 3612QE 2 1GHz 8GB RXx2N0F0F102A Intel Core i7 3555LE 2 5GHz 8GB DOS idle 40 C 13W 25W 18W 22W UEFI SETUP or shell 40 C 13W 26W 18W 23W VxWorks idle 40 C 12W 21W 21W 18W Windows 7 idle 40 C 21W 18W Windows 7 HeavyLoad Tool 40 C 43W 34W Windows 7 prime95 V28 7 40 C 15W 41W Windows 7 HeavyLoad ...

Page 59: ...erature the estimated battery life is 2 to 10 years Battery current is not drawn when the RXi Box IPC XP is supplied with 24V Regulatory CE EMC CE and designed to meet FCC Part 15 Class B DNV Box Dimensions o The RXi Box IPC XP dimensions are 252 mm x 207 mm o The RXi Box IPC XP height of a 0 slot RXE configuration is 76 mm RXM 117mm o The RXi Box IPC XP height of a 1 or 2 slot RXE configuration i...

Page 60: ...PACSystems RXi Box IPC XP Hardware Reference Manual GFK 2990 60 Internal ...

Page 61: ...product Geographical Regions World wide headquarter of GE Intelligent Platforms Inc is at GE Intelligent Platforms Inc 2500 Austin Drive Charlottesville VA 22911 U S A Web www ge ip com Europe Middle East and Africa headquarter of GE Intelligent PLATFORMS Inc is at GE Intelligent Platforms GmbH Co KG Memminger Str 14 Augsburg D 86 159 Germany GE Intelligent Platforms Inc uses two regional headquar...

Page 62: ...latforms product Free technical support is available by phone fax or email Telephone support is available at main locations or at the regional center where the product was bought Germany Monday through Thursday 8 00 17 00 CET Friday 8 00 16 00 CET Phone 49 821 5034 170 Fax 49 821 5034 119 E Mail support augsburg ip ge com Table 26 Support contact ...

Page 63: ...ra www fedora redhat com IBM Corp www ibm com Intel Corp www intel com Linear Technology www linear tech com Microsoft Corp www microsoft com Freescale Corp www freescale com Novell www novell com NVIDIA www nvidia com Pericom www pericom com PCI Industrial Computer Manufacturing Group www picmg org PLX Technology www plxtech com QNX Software Systems www qnx com Red Hat www redhat com VITA www vit...

Page 64: ...orms contact support at these email addresses repairs augsburg ip ge com In case of difficulties provide at least the information listed below to an appropriate support center or on their web site as listed above RMA Number if applicable Product Serial Number Part Number Version Contact Name Phone Number Detailed Description of the Problem Defect ...

Page 65: ...CC Federal Communication Commission USA GPIO General Purpose I O GT Giga Transfers I O Input Output IRQ Interrupt ReQuest LAN Local Area Network LED Light Emitting Diode LV Low Voltage NVRAM Non Volatile Random Access Memory PCH Peripheral Controller Hub PCI Peripheral Component Interconnect PCIe Peripheral Component Interconnect Express POST Power On Self Test RMA Return Material Authorization RT...

Page 66: ...PACSystems RXi Box IPC XP Hardware Reference Manual GFK 2990 66 Internal ...

Page 67: ... with which the Combined Work was made is also called the Linked Version The Minimal Corresponding Source for a Combined Work means the Corresponding Source for the Combined Work excluding any source code for portions of the Combined Work that considered in isolation are based on the Application and not on the Linked Version The Corresponding Application Code for a Combined Work means the object c...

Page 68: ...able for and under terms that permit the user to recombine or relink the Application with a modified version of the Linked Version to produce a modified Combined Work in the manner specified by section 6 of the GNU GPL for conveying Corresponding Source o 1 Use a suitable shared library mechanism for linking with the Library A suitable mechanism is one that a uses at run time a copy of the Library...

Page 69: ...ic License shall apply that proxy s public statement of acceptance of any version is permanent authorization for you to choose that version for the Library 2013 2016 GE Intelligent Platforms Embedded Systems Inc All rights reserved indicates a trademark of GE Intelligent Platforms Inc and or its affiliates All other trademarks are the property of their respective owners Confidential Information Th...

Reviews: