PACSystems RXi Box IPC-XP Hardware Reference Manual
GFK-2990 25
Internal
Flat wall mounting through the box
The choice of correct screws depends on the nature of the wall. The box has 4 drills with a diameter of 5.1 mm.
So the maximum screw diameter cannot be higher than 5 mm.
Remove the front lid by opening the 4 screws with a screw driver (Torx-20). You will find the 4 holes on the left
and right side inside the box (red marked on the picture below). The thickness of the box is 28 mm at these
locations.
Figure 4: Flat wall mounting through the box – illustration
Take the distances of the holes and the clearances from the drawing in chapter 9.1. After fixing the IPC with
sufficient long screws and torque close the IPC with the front lid with a torque of 1 Nm for the lid screws.