background image

PACE Series Calibration Manual

[EN] English

iii

K0450 Revision B

Associated Publications

K0447 PACE5000/6000 User Guide and Safety Instructions
K0467 PACE1000 Indicator User Guide and Safety Instructions
K0443 PACE5000/6000 Controller User Manual
K0470 PACE1000 Indicator User Manual
K0476 Pressure Control Module User Guide and Safety Instructions
K0472 SCPI Communications Manual
K0469 Heritage Communications Manual - Instrument Emulation

Symbols

RtMach

Rate of Mach

SCPI

Standard Commands for Programmable Instruments

UUT

Unit under test

V

Volts

VFC

Volts-free contact

+ve

Positive

-ve

Negative

°C

Degrees Celsius

This equipment meets the requirements of all relevant European safety directives. 
The equipment carries the CE mark.

This symbol, on the equipment, indicates that the user should read the user 
manual.

This symbol, on the equipment, indicates a warning and that the user should refer 
to the user manual.
Ce symbole, sur l’instrument, indique que l’utilisateur doit consulter le manuel 
d’utilisation. Ce symbole, dans le manuel, indique une situation dangereuse.

This symbol warns the user of the danger of electric shock.
Ce symbole alerte l’utilisateur sur le danger de choc électrique.

Do not dispose of this product as household waste. Use an approved organisation 
that collects and/or recycles waste electrical and electronic equipment. For more 
information, contact one of these:
 - Our customer service department: 

www.gemeasurement.com

 - Your local government office.

Summary of Contents for PACE5000

Page 1: ...GE Digital Solutions Pressure Automated Calibration Equipment Calibration manual K0450 Revision B PACE5000 PACE6000 PACE1000...

Page 2: ...ons are subject to change without notice GE is a registered trademark of General Electric Company Other company or product names mentioned in this document may be trademarks or registered trademarks o...

Page 3: ...ge Use suitably qualified calibration technicians and good engineering practice for all procedures in this publication Pressure Do not apply pressures greater than the maximum working pressure to the...

Page 4: ...d airspeed i e That is IEC International Electrotechnical Commission IEEE 488 Institute of Electrical and Electronic Engineers standard 488 data in Inch kg Kilogram kts kn knot LCD Liquid crystal disp...

Page 5: ...ets the requirements of all relevant European safety directives The equipment carries the CE mark This symbol on the equipment indicates that the user should read the user manual This symbol on the eq...

Page 6: ...RE APPLYING PRESSURE EXAMINE ALL FITTINGS AND EQUIPMENT FOR DAMAGE REPLACE ALL DAMAGED FITTINGS AND EQUIPMENT DO NOT USE ANY DAMAGED FITTINGS AND EQUIPMENT DO NOT EXCEED THE MAXIMUM WORKING PRESSURE O...

Page 7: ...r the list of selectable pressure units Pressure units Factor hPa Pressure units Factor hPa mbar 1 0 cmH2O 20 C 0 978903642 bar 1000 0 mH2O 20 C 97 8903642 Pa N m2 0 01 kg m2 0 0980665 hPa 1 0 kg cm2...

Page 8: ...es on Calibration 1 5 1 PACE Controller Connection 2 Gauge Reference 2 5 2 PACE Indicator Connection 3 Gauge Reference 3 6 Calibration Check All Ranges 4 6 1 Procedure 4 7 Calibration Adjustment 5 App...

Page 9: ...rement uncertainty of the original calibration standard To preserve uncertainty of the PACE calibration checks and adjustments must be performed using a calibrator uncertainty of less than or equal to...

Page 10: ...open to atmosphere Turn the valve to the closed position Gauge Reference If the pressure standard has a reference connection then connect this to the PACE reference port on the module manifold Otherw...

Page 11: ...essure standard has a reference connection then connect this to the indicator reference port Otherwise the indicator reference port should be open to atmosphere Note Indicator reference port open to a...

Page 12: ...e to the first pressure value and wait until this pressure as displayed on PACE is stable to less than 10ppm 0 001 Display filtering may be required 4 Compare the pressure value on the calibration sta...

Page 13: ...e to be set on the pressure standard and to press OK when the applied pressure is stable Use the numeric keys to enter the precise applied pressure Note The display also shows throughout this procedur...

Page 14: ...K0450 Revision B 6 EN English Appendix A PACE Menus and Screens A 1 PACE Controller Menus Calibration procedure next page...

Page 15: ...PACE Series Calibration Manual EN English 7 K0450 Revision B A 2 PACE Controller Screens...

Page 16: ...K0450 Revision B 8 EN English A 3 PACE Indicator Menus Calibration procedure next page...

Page 17: ...PACE Series Calibration Manual EN English 9 K0450 Revision B A 4 PACE Indicator Screens...

Page 18: ......

Page 19: ......

Page 20: ...www gemeasurement com...

Reviews: