ARMING YOUR SYSTEM IN THE “STAY” MODE 

STAY is used when the user is inside the premise and wants protection 

around the perimeter.  

 

Close all protected doors and windows. 

Step 1  

• 

Ready

 icon must be on or flashing when all protected zones and 

sensors are secure. 

NOTE: 

If any zones are bypassed, a sensor in 

that zone can be violated without affecting the 

ready 

icon

.

 

• 

The security system will not arm if the 

not ready 

icon

 

is on or 

flashing. 

• 

If the 

power 

icon is off, you have no AC power. Restore power if 

possible. If not, contact your installing company listed on page 1 
of this booklet for service. 

 

Step 2 

• 

Enter your 4 or 6 digit user code. 

• 

If “Auto Bypass” is enabled, all interior zones will be bypassed if 
you do not leave through a designated entry/exit door.  If Auto 
Bypass is enabled, omit Step 3. 

• 

When “Auto Instant” is enabled, if you do not leave through a 
designated entry/exit door the 

instant 

icon will illuminate 

indicating that the entry/exit doors no longer have an entry delay. 
If “Auto Instant” is enabled, omit Step 4. 

 

Step 3 

• 

Press the [

STAY

] key. 

• 

The 

stay light

 will illuminate indicating that all interior zones are 

bypassed.  (All interior devices will bypass automatically, giving 
the user freedom of movement within the interior area.) 

• 

The 

bypass light

 will illuminate if any zone(s) are bypassed. If any 

zone(s) have been bypassed previously by the user, the icon(s) 
corresponding to the bypassed zone(s) will illuminate, alerting the 
user that a zone(s) may be unprotected and can be faulted 
without an alarm. 

 

Summary of Contents for NX-1448E - Security NetworX 48-Zone Fixed

Page 1: ...NX 1448E Fixed English Keypad User s Manual ...

Page 2: ... partitioned EMERGENCY ACTIVATION KEYS check if enabled Fire Auxiliary Emergency Police PROGRAMMED FUNCTIONS Abort Delay s Cancel Alarm Forced Arming s Auto Bypass s Change Partitions Group Bypass s Auto Instant Chime Quick Arm s Battery Test Communicator Test Re Exit Siren Test s These features should not be enabled on UL listed systems ENTRY EXIT DELAY TIMES Exit Delay Time __________ Secondary ...

Page 3: ..._______ 11 _________________________ 35 _________________________ 12 _________________________ 36 _________________________ 13 _________________________ 37 _________________________ 14 _________________________ 38 _________________________ 15 _________________________ 39 _________________________ 16 _________________________ 40 _________________________ 17 _________________________ 41 ____________...

Page 4: ...ble to turn on ARM your System by simply pressing the STAY or EXIT key The system must always be disarmed using a 4 or 6 digit code The LED keypad includes up to 60 icons and a built in electronic sounder These provide specific information relating to the status of the security system which is described in the booklet Understanding what the icons and sounds mean will help you easily operate your s...

Page 5: ...e qualified security professionals to install and maintain your security system It may be possible to arm the security system without the backup battery connected Your periodic test should be done with AC Power removed to verify the battery is connected and adequately charged Care should be taken to plug in and restrain the AC Transformer after testing Please read the following information and ins...

Page 6: ...SS LIGHT 11 CANCEL LIGHT 11 CHIME LIGHT 11 EXIT LIGHT 11 FIRE ICON 11 INSTANT ICON 12 LISTEN IN ICON 12 POWER ICON 12 READY NOT READY ICON 12 SILENCED ICON 12 STAY LIGHT 12 TAMPER TROUBLE ICONS 12 ZONE ICON 12 KEYPAD FUNCTIONS 13 ARMING YOUR SYSTEM IN THE AWAY MODE 13 ARMING YOUR SYSTEM IN THE STAY MODE 14 USING THE QUICK ARM 15 CHANGING MODES WHILE SYSTEM IS ARMED 15 ...

Page 7: ...ON AND OFF 17 CHANGING USER CODES 17 ASSIGNING USER CODE AUTHORITY LEVELS 18 OTHER KEYPAD FUNCTIONS 20 SETTING THE KEYPAD TONE 20 CHANGE PARTITION Optional 20 VIEW ALARM MEMORY 20 TEST FUNCTION Optional 21 RESET FUNCTION 21 SET SYSTEM DATE 21 SETTING THE SYSTEM CLOCK 22 SETTING THE KEYPAD LIGHTING 23 SERVICE MENU 23 KEYPAD CONTROL TONES BEEPS 25 EMERGENCY EVACUATION PLANS 26 ...

Page 8: ...ows a special code to be sent to the central station that indicates the alarm system is being operated under duress Forced Arming An option that allows the system to be turned on ARMED with one or more zones open A system that is ready to be force armed will flash the ready icon Note Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 d...

Page 9: ...tem by pressing either the STAY or EXIT key on the keypad control for ARMING only as programmed by the installing company User Code A four 4 or six 6 digit entry code used to arm or disarm the system ICON KEYPAD DISPLAY Armed Instant Ready FIRE Power Service Enter Code Silenced Trouble Tamper 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 3...

Page 10: ...ng center an emergency report could be sent to that center Auxiliary Emergency Key This key can activate the auxiliary alarm when pressed for two seconds If your system is connected to a monitoring center an emergency report could be sent to that center Police Panic Hold Up Key This key can sound a local audible alarm when pressed for two seconds If your system is connected to a monitoring center ...

Page 11: ... abort feature must be enabled Entering a code followed by the CANCEL key during or after an alarm report to the central station will cause the cancel light to come on It will stay on until the central station has received the cancel report Note The cancel feature must be enabled CHIME LIGHT The chime light is on when the chime feature is on off otherwise EXIT LIGHT The exit light is on during the...

Page 12: ...on is on when the system is ready to arm and flashes if ready to force arm The not ready icon is on when the system is not ready to arm because of a zone s being faulted SILENCED ICON The silenced icon appears after a code has been entered to silence the siren but the zone has not been cleared STAY LIGHT The stay light is on when all interior motion detector zones are bypassed TAMPER TROUBLE ICONS...

Page 13: ...rs are secure NOTE If any zones are bypassed a sensor in that zone can be violated without affecting the ready icon The security system will not arm if the not ready icon is on or flashing If the power icon is off you have no AC power Restore power if possible If not contact your installing company listed on page 1 of this booklet for service Step 2 Enter your 4 or 6 digit user code to arm the sys...

Page 14: ...Auto Bypass is enabled all interior zones will be bypassed if you do not leave through a designated entry exit door If Auto Bypass is enabled omit Step 3 When Auto Instant is enabled if you do not leave through a designated entry exit door the instant icon will illuminate indicating that the entry exit doors no longer have an entry delay If Auto Instant is enabled omit Step 4 Step 3 Press the STAY...

Page 15: ... the instant icon Optional Press the BYPASS key at this time to turn on off toggle all designated interior zones Optional When armed pressing the EXIT key will start the exit delay enabling you to leave the building IMPORTANT The instant icon needs to be off at this time if you plan on re entering the building otherwise you will create an alarm You may restore an entry delay by pressing the STAY k...

Page 16: ... the system is in the disarmed state The following steps are used for bypassing zones Step 1 Press the BYPASS key Step 2 Enter user code if required optional The bypass light flashes Step 3 Enter 1 or 2 digits indicating the zone you wish to bypass i e press the 1 key for zone 1 press 1 2 for zone 12 Step 4 Press the BYPASS key again Step 5 The corresponding zone icon will illuminate indicating th...

Page 17: ...chime is off the chime light will be off Each press of the CHIME key will toggle the chime feature on off and produce a momentary ding dong sound ADDING AND CHANGING USER CODES Your system must be Disarmed to change user codes Step 1 Press r 5 Step 2 The Enter Code icon will display Enter a Master Arm Disarm Code N For partitioned systems someone changing the code of another person must have acces...

Page 18: ... key while the ready icon is flashing to exit the User Code Programming Mode ASSIGNING USER CODE AUTHORITY LEVELS Assign authority levels to users by following the steps below Assign user codes before assigning authority levels Step 1 Press r 6 Master Arm Disarm Code N Someone changing the authority of another person can only add or remove partition authorization for partitions to which they have ...

Page 19: ...you to the partition enable The user has access in partitions that are illuminated Step 6 The illuminated numbers indicate each partition where the user has access To change any of the partitions where the user has access press numbers corresponding to areas where you want to give the user access or deny access Example If zone icon 2 is lit then the user is assigned access to partition 2 By pressi...

Page 20: ...ake the keypad sounder go to higher tones pressing the key will make the keypad sounder go to lower tones Step 3 When the desired tone is reached press the key to set this tone and exit from the Adjust Tone mode CHANGE PARTITION Optional Step 1 Press r 1 Step 2 Press a NUMBER key between 1 and 8 to change partitions momentarily Step 3 If no other key is pressed it will go back to its standard part...

Page 21: ...nter a user code to silence the siren RESET FUNCTION This function is used to reset Smoke Detectors Zone Troubles and Zone Tampers Your system must be Disarmed to use the Reset function Step 1 Press r 7 Resets have now been performed Step 2 If the keypad begins beeping the reset did not execute properly Enter your code to silence the keypad Wait a few minutes and repeat step 2 to attempt another r...

Page 22: ... will appear Step 2 Enter a Master Code Then the service icon will begin to flash Step 3 Enter the hour code which must be two 2 digits Note The clock is a 24 hour clock Refer to the following table Step 4 Enter the minutes code which must be two 2 digits Then the ready icon will come on constant Example 7 minutes after would be entered 0 7 Time Hour Code Time Hour Code Time Hour Code 12 00 Midnig...

Page 23: ...l be on If the service icon is flashing one or more zone icon s will illuminate indicating what service s is required Press the and to scroll between tamper trouble and other service conditions Call your service provider immediately for these problems The following table provides a list of what each icon means in a service condition ICON PROBLEM SYSTEM FAULT Press the 1 key The zone icon s that is...

Page 24: ...e as they correspond to these service conditions 1 5 Reserved 6 Telephone Line Trouble Line Cut 7 Aux communication device failure 6 The service icon will remain lit until the trouble clears and a user code is entered SEE NOTE AT END OF TABLE 7 FAILURE TO COMMUNICATE This icon will illuminate when there is a failure to communicate between your system and the central station SEE NOTE AT END OF TABL...

Page 25: ... the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any zone s are bypassed Pulses when the armed status changes and a low battery is detected Pulses when the armed status changes and a Tamper condition is detected Beeps to indicate Telephone Line Cut if selected Pulses when one or more of the following conditions are detected Zone ...

Page 26: ... escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the Fire Department from a neighbor s phone NOTE After ...

Page 27: ...NX1448E Icon Keypad Page 27 ...

Page 28: ...Page 28 NX1448E Icon Keypad SYSTEM NOTES ...

Page 29: ...NX1448E SERIES USER S MANUAL NX1448EUB03 REV B 1 10 03 ...

Reviews: