NX-8E CONTROL
22
L
LOCATION 35 - ZONES 41-48 ZONE TYPE (8 segments of numerical data)
Location 35 contains the Zone type for zones 41-48. Segment 1 is for zone 41 Segment 8 is for zone 48.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 36 - PARTITION SELECT, ZONES 41-48 (8 segments, feature selection data)
Location 36 is used to select the partition or partitions that zones 41-48 reside in. A zone may reside in any
combination of the 8 partitions. If a burglary zone resides in more than 1 partition it will only be active when
all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest
partition. Location 36 has 8 segments. Segment 1 corresponds to zone 41 and Segment 8 corresponds to zone
48.
Segments 1 - 8:
1 = Partition #1
3 = Partition #3
5 = Partition #5
7 = Partition #7
2 = Partition #2
4 = Partition #4
6 = Partition #6
8 = Partition #8
L
LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data)
Location 37 is used to enable various system feature and reporting options. (Refer to the feature definitions.)
Segment 1:
1 - On if siren sounds for "Telephone Line Cut" when armed.
2 - On if siren sounds for "Telephone Line Cut" when disarmed.
3 - On if siren blast at arming.
4 - On if siren blast at exit expiration.
5 - On if siren blast at closing kissoff.
6 - On if siren sounds during a "Cross Zone" verification time.
7 - On if siren sounds for a Zone or Box Tamper.
8 - On if siren blasts 1 time for keyswitch or wireless arming; 2 times for disarming.
Segment 2:
1 - On if siren driver should be a voltage output. Off if on board siren driver enabled.
2 - On if siren sounds for expander trouble (required for UL installations).
3 - On for Immediate Restore by zone. Off for zones to restore only when siren is off.
4 - On if Dynamic Battery Test performed at arming. Off if performed at disarming. (See location
40)
5 - On if Battery Missing Test is performed every 12 seconds.
6 - On if Manual Bell Test performed during [
r
]-[4]-[4] test function.
7 - On if Manual Communicator Test performed during [
r
]-[4]-[4] test function.
8 - On if Box Tamper terminals on the control panel are enabled.
Segment 3:
1 - On if Box Tamper report enabled.
2 - On if AC Fail reporting enabled.
3 - On if Low Battery reporting enabled.
4 - On if Aux. Power Overcurrent report enabled.
5 - On if Siren Supervision report enabled.
6 - On if Telephone Line Cut report enabled.
7 - On if Ground Fault Detection report enabled.
8 - On if Expander Trouble reporting enabled.
Segment 4:
1 - On if Fail To Communicate report enabled.
2 - On if Log Full report enabled.
3 - On if Autotest report enabled.
4 - On if Start/End programming report enabled.
5 - On if End Download report enabled.
6 - On if Sensor Low Battery report enabled.
7 - On if Sensor Missing report enabled.
8 - Reserved.
Segment 5:
1 = On enable Lost Clock service light.
2 = On enables Zone Doubling (requires NX-200 Zone Doubling Kit).
3 = On disables On-Board 8 zones.
4 = On will allow two trips on same cross-zone to activate an alarm.
5 = On will not allow zones that are force armed to report bypass.
6 = On enables Silent Exit option.
7 = Use internal crystal for clock.
8 = Disable Temporal Siren on Fire. NOTE: Do NOT disable for UL listed systems.