CHAPTER 17: MISCELLANEOUS COMMANDS
ALARM RELAYS
MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
17–5
17.1.3 Configuring Alarm Relays with EnerVista Secure Web Management Software
To customize the alarm relays,
Z
select the
Configuration > Alarm
menu item.
Each alarm can be enabled or disabled form the screen shown above. All alarms can be
enabled or disabled using the Alarm Status drop down menu. Relay closure times can be
set using the drop down menu.
Z
After changing the Alarm settings, save the configuration using the
save icon (
).
Alarm relays (continued)
ML1600(alarm)##
show alarm
Alarm Events Configuration
--------------------------
Alarm Status: DISABLED
Relay Closure Time Period: 5 Seconds
EventId
Description
Mode
------------------------------------------
1
S-RING OPEN
NOT ENABLED
2
Cold Start
MOMENTARY
3
Warm Start
NOT ENABLED
4
Link Up
MOMENTARY
5
Link Down
NOT ENABLED
6
Authentication Failure
MOMENTARY
7
RMON Raising Alarm
NOT ENABLED
8
RMON Falling Alarm
MOMENTARY
9
Intruder Alarm
MOMENTARY
10
Link Loss Learn Triggered
MOMENTARY
11
Broadcast Storm Detected
MOMENTARY
12
STP/RSTP Reconfigured
MOMENTARY
ML1600(alarm)##
exit
ML1600#