3–10
MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
CONNECTING A MGMNT CONSOLE TERMINAL TO THE ML1600
CHAPTER 3: INSTALLATION
3.5
Connecting a MGMNT Console Terminal to the ML1600
3.5.1
Description
Use a DB-9 null-modem cable or a DB-9 to USB null-modem cable to connect the ML1600
console port (the RS232 port) to the a PC. For HyperTerminal configuration, refer to the
MultiLink MNS software manual (publication number GEK-113043).
Note
Console cables may be purchased as a separate items. They are not included with the unit.
FIGURE 3–6: ML1600 console port
The pin assignment for the console port are indicated in the following table.
This information enables a MGMNT station (PC or console terminal) to connect directly to
the switch console using a straight-through serial cable.
Table 3–2: Console port pin assignment
Pin
Signal
Description
1
CD
Carrier detect (not used)
2
RXD
Receive data (input)
3
TXD
Transmit data (output)
4
open
not used
5
GND
Signal ground
6 to 9
open
not used
754713A1.CDR