Installation Instructions

WARNING: 

TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK OR INJURY TO 
PERSONS, OBSERVE THE FOLLOWING:

A.

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer.

B.

Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means 
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.

AVERTISSEMENT :

POUR RÉDUIRE LE RISQUE D’INCENDIE,
DE CHOC ÉLECTRIQUE OU DE BLESSURES

CORPORELLES, IL FAUT OBSERVER LES REGLES SUIVANTES :
A.

Utilisez cet appareil uniquement de la manière prévue 
par le fabricant. En cas de question, consultez le fabricant.

B.

Avant tout entretien, réparation ou nettoyage, coupez
l’alimentation électrique au disjoncteur et verrouillez le
panneau du disjoncteur pour éviter la mise sous tension
accidentelle. S’il est impossible de verrouiller le panneau 
du disjoncteur, attachez solidement une note de mise en
garde très visible, comme une étiquette, au panneau.

CAUTION: 

For General Ventilating Use 

Only. Do Not Use To Exhaust Hazardous Or 
Explosive Materials And Vapors.

ATTENTION : 

Utilisez uniquement 

pour une ventilation générale. N’utilisez pas pour 
évacuer des vapeurs ou des matériaux 
dangereux ou explosifs.

WARNING: 

TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK OR INJURY TO 
PERSONS, OBSERVE THE FOLLOWING:

A.

Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction. 

B.

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society 
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

C.

When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.

D.

Ducted fans must always be vented to the outdoors.

• Local codes vary. Installation of electrical connections 

and grounding must comply with applicable codes. In 
the absence of local codes, the vent should be installed 
in accordance with National Electrical Code ANSI/NFPA 
70-1990 or latest edition.

BEFORE YOU BEGIN

Read these instructions completely and 
carefully.

•IMPORTANT

– 

Save these instructions for local

inspector’s use.

•IMPORTANT

– 

Observe all governing codes 

and ordinances.

Note to Installer

– Be sure to leave these 

instructions with the Consumer.

Note to Consumer

– Keep these instructions for

future reference.

Skill Level 

– Installation of this vent hood requires

basic mechanical and electrical skills.

Completion time

– 1 to 3 hours.

• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not 

covered under the Warranty.

For Monogram local service in your area, call
1.800.444.1845.

For Monogram service in Canada, call 1.888.880.3030.

For Monogram Parts and Accessories, call
1.800.626.2002.

CAUTION:

Due to the weight and size of these vent 
hoods and to reduce the risk of personal

injury or damage to the product, 

TWO PEOPLE ARE

REQUIRED FOR PROPER INSTALLATION.

ATTENTION :

À cause du poids et des dimensions du 
ces hottes et pour réduire les risques de

blessures ou de dommages du produit, 

IL FAUT 

DEUX PERSONNES POUR FAIRE UNE INSTALLATION
CORRECTE.

WARNING:

To reduce the risk of fire or electrical shock, 
do not use this range hood with any external

solid-state speed control device. Any such alteration
from original factory wiring could result in damage to
the unit and/or create an electrical safety hazard.

AVERTISSEMENT :

Pour réduire le risque d’incendie ou de 
choc électrique, il ne faut pas utiliser cette

hotte avec un régulateur de vitesse électronique
externe. Toute modification de ce type du branchement
d’usine peute endommager l’appareil ou créer un risque
de choc électrique.

TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.

Summary of Contents for Monogram ZVC30LSS

Page 1: ...Installation Instructions 30 36 and 48 Custom Hood Insert ZVC30LSS ZVC36LSS ZVC48LSS 49 80415 12 06 JR...

Page 2: ...ation and Air Conditioning Engineers ASHRAE and the local code authorities C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must...

Page 3: ...rries Jubilee Peppercorn Beef Flamb C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size o...

Page 4: ...mper Plate 19 Step 5 Install Blower Motor 20 Step 6 Connect Wiring Harness 20 Step 7 Install Filters 21 Step 8 Finalize Installation 21 PRODUCT CLEARANCES The vent hood and liner assembly must be inst...

Page 5: ...er is shipped with each hood insert This non combustible liner protects the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible line...

Page 6: ...er is shipped with each hood insert This non combustible liner protects the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible line...

Page 7: ...the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible liner Use the supplied liner as a template The opening must be 38 3 4 W x 1...

Page 8: ...of the control mounting assembly A 30 ft wire cord is provided Careful consideration must be given to the location of the remotely mounted control It is recommended that the 4 wire cord be routed thro...

Page 9: ...Round Duct 9 Advance Planning Total Equivalent Quantity Equivalent Duct Piece Dimensions Length Used Length Round 1 ft straight per foot length 3 1 4 x 12 1 ft 3 1 4 x 24 per foot straight length 8 ro...

Page 10: ...ve the liner foam and cardboard 3 Remove the tape securing the filters to the insert sleeve lift the tabs and remove the filters 4 Unscrew the 5 nuts securing the damper vent plate assembly and remove...

Page 11: ...nset hood while unpacking parts Blower motor Models ZVC30LSS and ZVC36LSS Insert sleeve Filters 2 wing nuts with lock washers for blower motor NOTE To be used on custom hood when controls are remotely...

Page 12: ...p to the ceiling On the ceiling measure 5 1 2 from the back wall to the centerline of an 8 1 2 hole Wall Ducting If ductwork will vent to the rear Use a level to draw a centerline straight up to the c...

Page 13: ...sleeve must be centered with the insert sleeve The insert sleeve should extend beyond the front and rear edge of the cooking appliance The insert sleeve in the ceiling must be centered left to right o...

Page 14: ...alled in a backsplash or countertop A cover plate is provided to cover the opening in the hood when the control is removed A 30 ft length of 4 wire cord is supplied to accommodate most installations B...

Page 15: ...the control with the 2 mounting plate screws 4 Pull the 4 wire cord through the opening in the wall the wall bracket and the back of the mounting bracket NOTE Use provided cable or cable designated b...

Page 16: ...rame the cutout opening to fit the liner NOTE The opening support must be 3 4 thick wood to accept the liner installation screws 2 Slide the liner up and into the opening until flush with bottom edges...

Page 17: ...tre maison est en aluminium assurez vous d utiliser un compos anti oxydant approuv et des raccords aluminium cuivre 1 Place insert sleeve on padded yet stable surface below cutout can use flattened ca...

Page 18: ...t to exhaust opening of insert sleeve and seal with aluminum tape NOTE House duct should drop to 11 1 2 above bottom edge of insert sleeve or the bottom of the 3 4 cabinet base 5 Tape the 4 washers in...

Page 19: ...embly and rotate so that vent side is up and bracket is located on left as you stand facing hood 2 Insert damper plate assembly into insert sleeve and carefully align with 8 house duct 3 Secure damper...

Page 20: ...While holding blower motor in place lift right side so that blower motor bolt holes align with bolts protruding from damper plate assembly and secure with lock washers and wing nuts hand tighten STEP...

Page 21: ...While maintaining slight backward pressure on filter open clip and press into place with two hands 3 To remove support filter with one hand while pulling filter clip down with the other STEP 8 FINALIZ...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Page 24: ...service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice GE...

Reviews: