Installation Preparation

REMOTE MOUNTING OF THE CONTROL
(WIRED) (CONT.)

COUNTERTOP 

1. 

Cut out opening in the countertop. Cutout
dimensions are 1-11/16

x 3-11/16

.

2. 

Loosen the 4 thumbscrews and remove the control
from the insert sleeve. Replace the control with the
blanking plate provided.

3. 

Attach the mounting plate to the back of the
control with the 2 mounting plate screws.

4. 

Pull the 4-wire cord through the opening in the
countertop, and through the back of the mounting
bracket.

NOTES: Use provided cable or cable designated by
the National Electrical Code, NFPA/ANSI 70, or local
codes. Not for telecommunication (telephone)
network.
5. 

Connect the 4-wire cord to the jack of the
connector on the control.

6. 

Press the control firmly into the mounting bracket
so that the clips engage. 

7. 

Apply silicone around the cutout opening.

8. 

Insert the control into the cutout opening.

WALL MOUNT

1. 

Cut out opening into the wall surface. Cutout
dimensions are 1-11/16

x 3-11/16

.

2. 

Loosen the 4 thumbscrews and remove the
control from the insert sleeve. Replace the 
control with the blanking plate provided.

3. 

Attach the mounting plate to the back of the
control with the 2 mounting plate screws.

4. 

Pull the 4-wire cord through the opening in 
the wall, the wall bracket and the back of the
mounting bracket.

NOTE: Use provided cable or cable designated by
the National Electrical Code, NFPA/ANSI 70, or local
codes. Not for telecommunication (telephone)
network.

5. 

Connect the mounting bracket to the wall bracket
using the two wall bracket screws. Only start the
first 1–2 threads of the screws into the wall, as
you want to leave a gap between the two
brackets to account for the wall thickness.

6. 

Raise the tabs on the mounting
bracket so the bracket will fit
through the wall opening.

7. 

Angle the mounting and wall
brackets and slide them through the wall cutout.

NOTE: Attach a string to the brackets, so you can
retrieve them from behind the wall if dropped.

8. 

Flatten tabs on mounting bracket so they are
flush with the wall surface, and tighten the wall
bracket screws to pull the wall bracket flanges
flush with the backside surface of the wall.

9. 

Connect the 4-wire cord to the jack of the
connector on the control.

10. 

Press the control firmly into the mounting 
bracket so that the clips engage.

4-wire cord

Mounting bracket

Screws

Connector

Apply silicone around
cutout opening

Mounting plate

Control

4-wire cord

Screws

Jack

Mounting
plate

Control

Wall 
bracket

Mounting
bracket

Tabs

Summary of Contents for Monogram ZVC30LSS

Page 1: ...Installation Instructions 30 36 and 48 Custom Hood Insert ZVC30LSS ZVC36LSS ZVC48LSS 49 80415 12 06 JR...

Page 2: ...ation and Air Conditioning Engineers ASHRAE and the local code authorities C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must...

Page 3: ...rries Jubilee Peppercorn Beef Flamb C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size o...

Page 4: ...mper Plate 19 Step 5 Install Blower Motor 20 Step 6 Connect Wiring Harness 20 Step 7 Install Filters 21 Step 8 Finalize Installation 21 PRODUCT CLEARANCES The vent hood and liner assembly must be inst...

Page 5: ...er is shipped with each hood insert This non combustible liner protects the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible line...

Page 6: ...er is shipped with each hood insert This non combustible liner protects the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible line...

Page 7: ...the underside of the canopy Custom Liner If you are not using the supplied liner you may construct a custom non combustible liner Use the supplied liner as a template The opening must be 38 3 4 W x 1...

Page 8: ...of the control mounting assembly A 30 ft wire cord is provided Careful consideration must be given to the location of the remotely mounted control It is recommended that the 4 wire cord be routed thro...

Page 9: ...Round Duct 9 Advance Planning Total Equivalent Quantity Equivalent Duct Piece Dimensions Length Used Length Round 1 ft straight per foot length 3 1 4 x 12 1 ft 3 1 4 x 24 per foot straight length 8 ro...

Page 10: ...ve the liner foam and cardboard 3 Remove the tape securing the filters to the insert sleeve lift the tabs and remove the filters 4 Unscrew the 5 nuts securing the damper vent plate assembly and remove...

Page 11: ...nset hood while unpacking parts Blower motor Models ZVC30LSS and ZVC36LSS Insert sleeve Filters 2 wing nuts with lock washers for blower motor NOTE To be used on custom hood when controls are remotely...

Page 12: ...p to the ceiling On the ceiling measure 5 1 2 from the back wall to the centerline of an 8 1 2 hole Wall Ducting If ductwork will vent to the rear Use a level to draw a centerline straight up to the c...

Page 13: ...sleeve must be centered with the insert sleeve The insert sleeve should extend beyond the front and rear edge of the cooking appliance The insert sleeve in the ceiling must be centered left to right o...

Page 14: ...alled in a backsplash or countertop A cover plate is provided to cover the opening in the hood when the control is removed A 30 ft length of 4 wire cord is supplied to accommodate most installations B...

Page 15: ...the control with the 2 mounting plate screws 4 Pull the 4 wire cord through the opening in the wall the wall bracket and the back of the mounting bracket NOTE Use provided cable or cable designated b...

Page 16: ...rame the cutout opening to fit the liner NOTE The opening support must be 3 4 thick wood to accept the liner installation screws 2 Slide the liner up and into the opening until flush with bottom edges...

Page 17: ...tre maison est en aluminium assurez vous d utiliser un compos anti oxydant approuv et des raccords aluminium cuivre 1 Place insert sleeve on padded yet stable surface below cutout can use flattened ca...

Page 18: ...t to exhaust opening of insert sleeve and seal with aluminum tape NOTE House duct should drop to 11 1 2 above bottom edge of insert sleeve or the bottom of the 3 4 cabinet base 5 Tape the 4 washers in...

Page 19: ...embly and rotate so that vent side is up and bracket is located on left as you stand facing hood 2 Insert damper plate assembly into insert sleeve and carefully align with 8 house duct 3 Secure damper...

Page 20: ...While holding blower motor in place lift right side so that blower motor bolt holes align with bolts protruding from damper plate assembly and secure with lock washers and wing nuts hand tighten STEP...

Page 21: ...While maintaining slight backward pressure on filter open clip and press into place with two hands 3 To remove support filter with one hand while pulling filter clip down with the other STEP 8 FINALIZ...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Page 24: ...service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice GE...

Reviews: