MDS 05-3438A01, Rev. F
MDS 4790/9790 Series I/O Guide
65
Group 3—Diagnostic Screens (
Page 77
)
The Diagnostic screens display important status information for the
local and remote radio, as well as run several tests useful in locating
system problems.
Group 4—Event Log (
Page 79
)
The event log lists up to 800 of the most recent operating changes. These
events include system problems,
as well as normal operator actions
such as turning the power on or off.
The following table organizes front panel screens in the same way as the
PC commands described earlier in this manual: operating parameters,
diagnostics, and radio information.
Table 15. Front Panel Screens—Configuration Parameters
FRONT PANEL
SCREEN
TERMINAL
COMMAND
DESCRIPTION
Access Level
Details, page 68
Enable or disable configuration mode.
Alarm Masks
Details, page 75
AMASK [0000
0000–FFFF FFFF]
Details, page 40
NMASK [0000
0000–FFFF FFFF]
Details, page 49
ASENSE [HI/LO]
Details, page 41
Set or show hexadecimal code identifying
whether alarm events cause an alarm output
relay to assert and cause the active radio to
switch over; also displays the alarm sense.
Battery Backup
Details, page 73
BATT(ery) [ON/OFF]
Details page 41
Enable or disable alarm generation when the
back-up battery falls below 13.0 Vdc.
Backlight Intensity
Details, page 76
Set or show front panel display’s background
brightness.
Baud Rate/Format
Details, page 70
BAUD [xxxxx abc]
Details, page 42
Set or show data interface port communica-
tion attributes.
Clear-to-Send Delay
Details, page 70
CTS [0-255]
Details, page 43
Set or show the time to wait after RTS is
asserted by the host computer before assert-
ing the CTS line.
Continuous Keying
Details, page 72
CKEY [ON/OFF]
Details, page 43
Select continuous or non-continuous keying.
Data Buffering
Details, page 74
BUFF [ON/OFF]
Details, page 42
Enable or disable data buffering.
Display Contrast
Details, page 75
Set or show front panel display’s foreground
character intensity.
Emphasis
Details, page 70
EMP [ON/OFF]
Details, page 46
Enable or disable pre-emphasis and
de-emphasis.
Key On Data
Details, page 73
DATAKEY [ON/OFF]
Details, page 44
Set or show keying behavior (key-on-data or
key-on-RTS).
Multi-Drop Address
(MADDR)
Details, page 72
MADDR [NONE, 1–255]
Details, page 48
Unit address for use with MDS’ InSite NMS
software, where multiple master stations are
connected at one location.
Manual Key
Details, page 72
DKEY
Details, page 45
KEY
Details, page 47
Manually key or dekey the transmitter.
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8457-MDS-UP-9790X.aspx