MDS 4790/9790 Series I/O Guide
MDS 05-3438A01, Rev. F
Entering the
RXTOT
command without a parameter displays the timer
value in minutes. Entering the
RXTOT
command with a parameter
ranging from 1 to 1440 resets the timer in minutes. Entering the
RXTOT
command with the parameter
NONE
disables the timer. The default value
is
NONE
.
Soft-Carrier Dekey
SCD [0-255]
The “soft-carrier dekey” command sets or displays the amount of time
to wait after a de-key request before actually de-keying the radio’s trans-
mitter.
Entering the
SCD
command without a parameter displays the timer value
in milliseconds. Entering the
SCD
command with a parameter ranging
from 0 to 255 resets the timer in milliseconds. The default setting is 0,
which means that the radio de-keys immediately following removal of a
keying signal
(
see “Simplex and Switched Carrier Operation” on
Page 4
).
If you experience problems with repeater operation after changing the
CTS
,
PTT,
or
SCD
values, contact GE MDS Technical Support.
Serial Number
SER
This command displays the radio’s serial number as recorded at the fac-
tory.
Show Selected
Parameters
SHOW [DC/PWR/CURRENT/RADIO]
The
SHOW
command discloses different types of radio information,
depending on the command parameter entered. These are:
•
DC
—Displays DC input/output voltages.
•
PWR
—Displays the actual (measured) RF power output in dBm.
Unlike the
PWR
command, this command shows the
actual
level
measured, not the programmed RF power setting.
•
CURRENT
—Shows the low noise amplifier and total board cur-
rent.
•
RADIO
—Shows the currently active radio (A or B).
Transmit Timeout screen
,