38
Operating Instructions
Safety Instructions
Installation Instructions
Tr
oubleshooting T
ips
Consumer Support
Read these instructions completely and carefully.
Installation of the range.
BEFORE YOU BEGIN
Installation of this range must conform with local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/NFPA.54, latest edition. This range has been
design-certified by CSA International according to ANSI Z21.1, latest edition.
As with any appliance using gas and generating
heat, there are certain safety precautions you
should follow. You will find these precautions in
the
Important Safety Information
section in the
front of this manual. Read them carefully.
IMPORTANT: OBSERVE ALL GOVERNING CODES
AND ORDINANCES.
NOTE:
This appliance must be properly grounded.
IMPORTANT:
Save these instructions for the local electrical
inspector’s use.
NOTE TO INSTALLER:
Leave these instructions with the
appliance after installation is completed.
NOTE TO CONSUMER:
Keep this Owner’s Manual and
Installation Instructions for future use.
SERVICER:
The electrical diagram is in an envelope attached
to the back of the range.
FOR YOUR SAFETY
Do not store or use combustible materials, gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
If you smell gas:
Open windows.
Don’t touch electrical switches.
Extinguish any open flame.
Immediately call your gas supplier.
CAUTION:
FOR PERSONAL SAFETY,
DO NOT USE AN EXTENSION CORD WITH THIS
APPLIANCE. REMOVE HOUSE FUSE OR OPEN CIRCUIT
BREAKER BEFORE BEGINNING INSTALLATION.
This appliance must be supplied with the proper
voltage and frequency, and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or time-delay fuse,
as noted on the rating plate.
Wiring must conform to National Electric Codes.
If the electric service provided does not meet the
above specifications, have a licensed electrician
install an approved outlet.
Because range terminals are not accessible after
range is in position, flexible service conduit or cord
must be used.
ELECTRICAL REQUIREMENTS
■
This product must be installed by a licensed
plumber or gas fitter.
■
When using ball type gas shut-off valves, they
shall be the T-handle type.
■
A flexible gas connector, when used, must not
exceed 3 feet.
IN THE COMMONWEALTH OF MASSACHUSETTS