Table 3. Setting DIP switches for the desired mode of operation
DIP
Switch
Function Setting
OFF =
Zoom in positive, zoom out negative
1 Zoom
Polarity
ON
=
Zoom in negative, zoom out positive
OFF =
Iris open positive, iris close negative
2 Iris
Polarity
ON
=
Iris open negative, iris close positive
OFF =
Not DC motors
3 Pan/Tilt
Drive
ON = DC
motors
4 OFF + 5 OFF = Normal
4 OFF + 5 ON = Random pan
4 ON + 5 OFF = 50% duty cycle
4 and 5
Autopan
4 ON + 5 ON = Disable autopan
OFF = Yes
6 Autopan
on
Power-Up
ON = No
OFF = 12
VDC
7 Zoom
Lens
Voltage
ON = 6
VDC
OFF = Not
inverted
8
Invert Up and
Down Tilt
ON = Inverted
4)
Supply power to the receiver.
5)
Wait 5 seconds.
6)
Set DIP switch 10 to the off position to place the receiver in normal
mode.