![GE IM-6D Owner'S Manual & Installation Instructions Download Page 45](http://html.mh-extra.com/html/ge/im-6d/im-6d_owners-manual-and-installation-instructions_127577045.webp)
49-60704-2
45
5
TIGHTEN THE PIPE CLAMP
Tighten the clamp screws until the sealing
washer begins to swell.
NOTE:
Do not overtighten or you may crush
the tubing.
8
FLUSH OUT THE TUBING
Turn the main water supply on and flush out the
tubing until the water is clear.
Shut the water off at the water
YDOYHDIWHUDERXWRQHTXDUW
liter) of water has been flushed
through the tubing.
9
CONNECT THE TUBING TO THE
REFRIGERATOR
NOTES:
Ŷ %HIRUHPDNLQJWKHFRQQHFWLRQWRWKH
refrigerator, be sure the refrigerator power
cord is not plugged into the wall outlet.
Ŷ ,I\RXUUHIULJHUDWRUGRHVQRWKDYHDZDWHU
ILOWHUZHUHFRPPHQGLQVWDOOLQJRQH,I\RXU
water supply has sand or particles that
could clog the screen of the refrigerator’s
ZDWHUYDOYH,QVWDOOLWLQWKHZDWHUOLQHQHDU
WKHUHIULJHUDWRU,IXVLQJ6PDUW&RQQHFW
Refrigerator Tubing kit, you will need an
DGGLWLRQDOWXEH:;;WRFRQQHFWWKH
filter. Do not cut plastic tube to install filter.
Remove the plastic flexible cap from the water
YDOYHUHIULJHUDWRUFRQQHFWLRQ
6
ROUTE THE TUBING
Route the tubing between the cold water line and
the refrigerator.
Route the tubing through a hole drilled in the wall
RUIORRUEHKLQGWKHUHIULJHUDWRURUDGMDFHQWEDVH
cabinet) as close to the wall as possible.
NOTE:
Be sure there is sufficient extra tubing
>DERXWIHHWFPFRLOHGLQWRWXUQVRIDERXW
FPGLDPHWHU@WRDOORZWKHUHIULJHUDWRUWR
move out from the wall after installation.
7
CONNECT TUBING VALVE
3ODFHWKHFRPSUHVVLRQQXWDQGIHUUXOHVOHHYH
for copper tubing onto the end of the tubing
and connect it to the shutoff valve.
Make sure the tubing is fully inserted into
the valve. Tighten the compression nut securely.
For plastic tubing from a SmartConnect™
Refrigerator Tubing kit, insert the molded end
of the tubing into the shutoff valve and tighten
compression nut until it is hand tight, then
tighten one additional turn with a wrench. Over
tightening may cause leaks.
Washer
,QOHW(QG
Pipe Clamp
Clamp
Screw
Saddle-Type
6KXWRႇ9DOYH
Compression Nut
Packing Nut
Outlet Valve
)HUUXOHVOHHYH
SmartConnect
™
Tubing
Installation Instructions
INST
ALLA
TION INSTRUCTIONS
NOTE:
Commonwealth of Massachusetts
Plumbing Codes 248CMR shall be adhered to.
Saddle valves are illegal and use is not permitted
in Massachusetts. Consult with your licensed
plumber.