background image

34 

QuickPanel

+

 Quick Start Guide 

GFK-2893K 

5.

 

Product Certifications and Installation 

Guidelines for Conformance 

The QuickPanel

+

 Operator Interface is intended for 

use in industrial environments and, when properly 
installed, shall comply with the following agency 
approvals. 

 

5.1  Agency Approvals 

Note:

 The agency approvals listed in the following 

table and on the Declaration of Conformities are 
believed to be accurate; However, the product’s 
agency approvals should be verified by the marking 
on the unit itself. 

Description 

Agency 

Marking 

Comments 

N.A. Safety for 
Programmable Controller 
for use in Hazardous 
locations 
 
Class I Division 2 Groups 
A, B, C, D (applicable to 
7'',10'',12'', 15'' Display 
units) 
 
Class I Division 2 Groups 
A, B, C, D; Class 2 
Division 2 Groups F, G; 
Class 3 Division 1 and 
Division 2 (applicable only 
to 6'' Display unit) 

 

Certification by 
Underwriter's 
Laboratories (UL) to  
UL 61010-1; UL 61010-
2-201;  
CSA C22.2 No 142–
M1987;  
CSA 61010-1;  
CSA 61010-2-201 
ISA 12.12.01 standard and 
CSA C22.2 No 213-M1987 

 
Explosive Atmospheres        
Directive European Safety 
for Hazardous Areas 
 
Equipment Group II, 
Category 3, Gas Groups 
IIC, Dust Group IIIC 
 
Protection string: 
II 3 G Ex nA IIC T4 Gc 
II 3 D Ex tc lllC T100°C   
(212 °F) Dc  
Tamb 0 to 55°C  
(32 to 131 °F) 

 

Certification in accordance 
with the ATEX Directive 
94/9/EC

 

with an 

Independent 3rd Party 
Assessment Certificate 
only applies to the 12” and 
15” Display units:           
EN 60079-0/A11,  
EN 60079-15, and  
EN 60079-31;  
Part numbers 
IC755CxS12CDBCA and 
IC755CxS15CDACA 

All manuals and user guides at all-guides.com

Summary of Contents for IC755CS06RD Series

Page 1: ...ckPanel Operator Interface IC755CxS06RDx 6 Display IC755CxW07CDx 7 Display IC755CxS10CDx 10 Display IC755CxS12CDx 12 Display IC755CxS15CDx 15 Display Quick StartGuide GFK 2893K Dec 2015 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...d could result in personal injury or death Caution Indicates a procedure condition or statement that if not strictly observed could result in damage to or destruction of equipment Attention Indicates a procedure condition or statement that should be strictly followed to optimize these applications All manuals and user guides at all guides com ...

Page 3: ...AN USB Host Ports Serial Interface LCD Active Area 115 2 x 86 4 mm 4 5 x 3 4 in 115 2 mm 4 5 in 192 mm 7 56 in x 2 36 mm 1 42 in x 2 137 mm 5 39 in x 2 183 50 mm 7 22 in 75 mm 2 95 in 75 mm 2 95 in 128 50 mm 5 06 in 144 7 mm 5 70 in Effective Screw Depth 6 mm 0 24 in Product Nameplate Battery Cover License Label IC755CxS06RDx Profile and Hardware Features Note Refer to the table IC755CxW06CDx Spec...

Page 4: ... Host Ports LAN Input Power SD Card MICRO USB LINE OUT MIC IN Status Indicator LED Touchscreen LCD IC755CxW07CDx Profile and Hardware Features Note Refer to the table IC755CxW07CDx Specifications for drawing dimensions All manuals and user guides at all guides com ...

Page 5: ...LED Touchscreen LCD SD Card USB Host Ports MICRO USB LAN2 COM1 LAN1 Input Power LINE OUT COM2 IC755CxS10CDx Profile and Hardware Features Note Refer to the table IC755CxS10CDx Specifications for drawing dimensions All manuals and user guides at all guides com ...

Page 6: ...uick Start Guide GFK 2893K IC755CxS12CDx Profile and Hardware Features Note Refer to the table IC755CxS12CDx Specifications for drawing dimensions All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 7: ...tatus Indicator LED SD Card Input Power LINE OUT USB Host Ports MICRO USB COM2 LAN2 COM1 LAN1 IC755CxS15CDx Profile and Hardware Features Note Refer to the table IC755CxS15CDx Specifications for drawing dimensions All manuals and user guides at all guides com ...

Page 8: ...Communications Ethernet Port 1x10 Base T 100 Base TX Serial Port 1x RS 232C COM1 5 pin connector USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Mic In Mono 3 5 mm jack 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise Voltage 1500 V p p Pulse Duration 1 μs Rise Time 1 ns Input power Rated Voltage 24 V dc 20 3 pin conn...

Page 9: ... 100Base T RJ 45 Serial Port 1x RS 232 UART port 5 pin connector USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Mic In Mono 3 5 mm jack 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise Voltage 1500 V p p Pulse Duration 1 μs Rise Time 1 ns Input power Rated Voltage 24 V dc 20 3 pin connector Power Consumption 15 W max...

Page 10: ... 100Base T RJ 45 Serial Port 1x RS 232 UART port 1x RS 232 485 port 2x 5 pin connector USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise Voltage 1500 V p p Pulse Duration 1 μs Rise Time 1 ns Input power Rated Voltage 12 24 V dc 20 3 pin connector Power Consumption 18 W maxim...

Page 11: ...S12CDA Serial Port 1x RS 232 UART port 1x RS 232 485 port 2x 5 pin connector 1x 10 pin connector for IC755CxS12CDA USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise Voltage 1500 V p p Pulse Duration 1 μs Rise Time 1 ns Input power Rated Voltage 12 24 V dc 20 3 pin connector ...

Page 12: ...00Base T RJ 45 Serial Port 1x RS 232 UART port 1x RS 232 485 port 2x 5 pin connector USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card slot Audio 1x Line Out Stereo 3 5 mm jack Noise Immunity Noise Voltage 1500 V p p Pulse Duration 1 μs Rise Time 1 ns Input power Rated Voltage 12 24 V dc 20 3 pin connector Power Consumption 30 W maximum...

Page 13: ...ollution Degree 2 Indoor use only Vibration Resistance 5 to 9 Hz single amplitude 3 5 mm 9 to 150 Hz constant accelerated velocity 9 8 m s2 X Y Z directions 10 time 100 minutes Compliance 3502 IEC61131 2 JIS B Altitude 800 1114 hPa altitude up to 2000 m 6561 68 ft RoHS Compliant with EU RoHS Directive 2011 65 EU Enclosure Rating IC755CxS06RDx UL Type 4X IP65 in panel mount only IC755CxW07CDx UL Ty...

Page 14: ...eneral Specifications The mating power terminal block supports stranded 30 to 14 AWG 0 05 to 2 00 mm 2 wires The user calculates proper gauge wiring for current carrying capacity and loss according to local regulations At a minimum the cable must be rated for 75 C 167 F or more Warning ELECTRICAL SHOCK HAZARD To avoid personal injury or damage to equipment ensure that the dc supply is disconnected...

Page 15: ...efer to the section Mounting on a VESA arm 3 The battery should only be installed when the unit is powered off 4 Care should be taken to protect and insert the battery with correct polarity 5 Do not use any metallic item to remove the battery such as screwdrivers knives pliers and so forth 6 Be careful to not drop the battery or any associated screws into the unit 7 Be careful of edges on internal...

Page 16: ...oting keyed orientation IC755CxS06RDx Battery Harness Connection 3 Verify that positive red is down and negative black is up 4 Wrap the harness connector around to match the following figure Do not let the harness connector go above the tab Harness Connector Orientation 5 Slide the battery cover into place taking care not to pinch the harness connector All manuals and user guides at all guides com...

Page 17: ...teries not specified for use with the QuickPanel product may present a risk of fire or explosion Caution Replace the battery for the IC755CxS06RDx only with GE battery part number IC755ACCBATT Caution Replace the battery for the IC755CxW07CDx only with GE battery part number IC755ACCBATT Caution Replace the battery for the IC755CxSxxCDx only with GE battery part number IC755ACCBATTNL All manuals a...

Page 18: ...ply dc power to the unit During normal startup and operation the QuickPanel status LED indicator displays as follows Solid amber while the QuickPanel unit is starting up Solid green during normal operation 6 Once power is applied the QuickPanel begins initializing The first thing to display is the splash screen To skip running any programs included in the StartUp folder tap Don t run StartUp progr...

Page 19: ... State QuickPanel State Amber solid Operating system starting Green solid Normal operating state Green blinking Backlight off Red blinking Backlight failure Off Power not applied to unit 3 4 2 Ethernet Port Operation LEDs The Ethernet port has two LED indicators Speed and Link Activity Speed Link Activity LED LED State Operating State Speed Yellow on 10 100 Link Activity Green on Link status All m...

Page 20: ...m the QuickPanel display screen 2 Wipe the display unit of any dust or fingerprints 3 Peel back a corner of the clear side of the protective sheet 4 Begin applying the corner to the display screen 5 Slowly apply the rest of the protective sheet smoothing out as you go 6 Peel the green curing film from the protective sheet All manuals and user guides at all guides com ...

Page 21: ...ard cables and mounting brackets Select a location that allows natural convection air flow from bottom to top of the QuickPanel enclosure Do not mount the QuickPanel at an angle more than 30 from the vertical as illustrated in the following figure Refer to the section Environmental Specifications Mounting Angle All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 22: ...ed the following equipment One 2 Phillips head screwdriver Mounting brackets supplied The mounting holes for the IC755CxS06RDx IC755CxW07CDx and IC755CxS10CDx are located on the top and bottom sides of the unit IC755CxS06RDx Mounting Holes IC755CxW07CDx Mounting Holes All manuals and user guides at all guides com ...

Page 23: ... 23 IC755CxS10CDx Mounting Holes The IC755CxS12CDx and IC755CxS15CDx mounting holes are located on the top bottom and sides of the unit IC755CxS12CDx Mounting Holes IC755CxS15CDx Mounting Holes All manuals and user guides at all guides com ...

Page 24: ...ickPanel 1 Cut an opening in the panel according to the specifications in the following figures Note Panel cutout tolerances are 0 50 0 00 mm 0 02 0 00 in Panel Thickness 1 0 to 5 0 mm 0 04 to 0 20 in 128 50 mm 5 06 in 183 50 mm 7 22 in IC755CxS06RDx Panel Cutout Dimensions Panel Thickness 1 0 to 5 0 mm 0 04 to 0 20 in 128 50 mm 5 06 in 183 50 mm 7 22 in IC755CxW07CDx Panel Cutout Dimensions All m...

Page 25: ...0 in 228 mm 8 98 in 302 mm 11 89 in IC755CxS12CDx Panel Cutout Dimensions Panel Thickness 1 6 to 5 0 mm 0 06 to 0 20 in 379 mm 14 92 in 305 mm 12 01 in IC755CxS15CDx Panel Cutout Dimensions 2 Verify that the gasket is present and properly seated in the bezel channel located on the sides of the unit 3 Insert the QuickPanel into the mounting panel cutout All manuals and user guides at all guides com...

Page 26: ...n the mounting bracket in a clock wise direction Torque Range for Mounting Clamp Screws Display Unit Torque Range IC755CxS06RDx 0 3 Nm 2 66 in lb IC755CxW07CDx 0 3 Nm 2 66 in lb IC755CxS10CDx 0 7 Nm 6 in lb IC755CxS12CDx 1 0 to 1 2 Nm 8 9 to 10 6 in lb IC755CxS15CDx 1 0 to 1 2 Nm 8 9 to 10 6 in lb All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 27: ...the unit displayed in the following figures The mounting holes for IC755CxS06RDx and IC755CxW07CDx attach with M4 screws that are 6 mm 0 24 in or less in length The mounting holes for IC755CxSxxCDx mounting holes attach with M4 screws that are 8 mm 0 32 in or less in length Torque Range for Mounting M4 Screws Display Unit Torque Range IC755CxS06RDx 0 7 to 0 8 Nm 6 2 to 7 1 in lb IC755CxW07CDx 0 7 ...

Page 28: ...CxS06RDx VESA Mounting Holes 100 mm 100 mm 100 mm 3 94 in 100 mm 3 94 in IC755CxSxxCDx VESA Mounting Holes Note For user manuals product updates and other information go to the Support website http www ge ip com support and refer to Operator Interfaces and PC All manuals and user guides at all guides com ...

Page 29: ...C755CxSxxCDA supports both 12 V dc or 24 V dc IN 4 6 2 Ethernet Port Details Interface Ethernet 10BASE T 100BASE TX Pin Signal Name Pin out 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC 4 6 3 USB Host Port Details Interface 2x USB 2 0 Pin Signal Name Pin out 1 USB_VCC 2 USB_D 3 USB_D 4 USB_GND All manuals and user guides at all guides com ...

Page 30: ... 6 4 Serial Port Details 4 6 4 1 IC755CxS06RDx 4 6 4 1 1 Serial Port COM1 Interface RS 232 Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND Pin 1 Pin 5 1 2 3 4 5 IC755CxS06RDx Serial Port COM1 Pin out All manuals and user guides at all guides com ...

Page 31: ...rt Guide 31 4 6 4 2 IC755CxW07CDx Interface x1 RS 232 Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND Pin 1 Pin 5 1 2 3 4 5 IC755CxW07CDx Serial Port COM1 Pin out All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 32: ...k Start Guide GFK 2893K 4 6 4 3 IC755CxSxxCDx 4 6 4 3 1 Serial Port COM1 Interface RS 232 Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND C755CxSxxCDx Serial Port COM1 Pin out All manuals and user guides at all guides com ...

Page 33: ...al Name Signal Name Full duplex Signal Name Half duplex 1 TXD TXD DATA 2 RXD TXD DATA 3 RTS RXD DATA 4 CTS RXD DATA 5 SGND SG SG Full duplex RS 485 is backwards compatible to RS 422 mode Pins 1 3 and 2 4 are connected internally Pin 1 Pin 5 COM2 COM1 5 4 3 2 1 C755CxSxxCDx Serial Port COM2 Pin out All manuals and user guides at all guides com ...

Page 34: ... 7 10 12 15 Display units Class I Division 2 Groups A B C D Class 2 Division 2 Groups F G Class 3 Division 1 and Division 2 applicable only to 6 Display unit Certification by Underwriter s Laboratories UL to UL 61010 1 UL 61010 2 201 CSA C22 2 No 142 M1987 CSA 61010 1 CSA 61010 2 201 ISA 12 12 01 standard and CSA C22 2 No 213 M1987 Explosive Atmospheres Directive European Safety for Hazardous Area...

Page 35: ... and the ATEX marking for Zone 2 explosive atmospheres Suitable for use in Class I Division 2 Groups A B C D applicable to 7 10 12 15 Display units Suitable for use in Class I Division 2 Groups A B C D Class 2 Division 2 Groups F G Class 3 Division 1 and Division 2 applicable only to only 6 Display unit Suitable for Group II Category 3 Gas Groups IIC Dust Group IIIC applicable only to the IC755CxS...

Page 36: ...0 of the peak rated voltage value at the supply terminals to the equipment USB retaining clamp must be used in hazardous location installations as follows 1 Connect the USB cable 2 Insert the retaining clamp in the port above the USB connector 3 Adjust the position of the retaining clamp by pushing the lever of the retaining clamp Close the retaining clamp to fit the size of the cable All manuals ...

Page 37: ...wn to be non hazardous EXPLOSION HAZARD Substitution of components may impair suitability EXPLOSION HAZARD DO NOT VESA MOUNT Panel mount only with enclosures that shall only be opened with the use of a tool in an area where the risk of impact is low DO NOT MAKE ANY CONNECTIONS TO THE MINI USB MIC TERMINAL AS IT WILL INVALIDATE THE ATEX APPROVAL All manuals and user guides at all guides com ...

Page 38: ... radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user is required to correct the interference at their own expense Changes or modifications to this unit that are not expressly approv...

Page 39: ... considerations were taken into account Shielding USB cables Limiting RS 232 cables to 15 m 49 2 ft in length Using Audio ports only during operational maintenance Although these considerations were deliberated during testing actual EMC environments vary greatly Therefore these considerations may not be necessary Likewise additional measures such as filtering wire separation and cable routing may ...

Page 40: ...utionprovider ip ge com Technical Support If you have technical problems that cannot be resolved with the information in this manual contact us by telephone or email or on the web at http support ge ip com Americas Online Technical Support http support ge ip com Phone 1 800 433 2682 International Americas Direct Dial 1 780 420 2010 if toll free 800 option is unavailable Technical Support Email sup...

Page 41: ...ic Online Technical Support http support ge ip com Phone 86 400 820 8208 86 21 3217 4826 India Indonesia and Pakistan Technical Support Email Support cn ip ge com China support jp ip ge com Japan support in ip ge com remaining Asia customers Customer Care Email customercare apo ip ge com customercare cn ip ge com China www ge ip com Copyright 2014 2015 GE Automation Controls Inc All Rights Reserve...

Reviews: