Product Certifications and Installation Guidelines for Conformance
GFK-2785C
PACSystems* RXi Box IPC
37
Standards Overview
For environmental specifications, refer to chapter 1.
EMC Emissions and Immunity Specifications
EMC EMISSIONS
Emissions
CISPR 11/EN 55011/
EN55016-2-3
30 – 1000 MHz, radiated, Group 1, Class A,
FCC 47CFR15
30 – 7500 MHz, radiated, Class A
CISPR 22/EN55022
30 – 6000 MHz, radiated, Class A,
Ethernet port: 0.15 – 30 MHz, conducted, Class A
EMC IMMUNITY
Electrostatic Discharge
EN61000-4-2
2
/EN55024/CISPR 24/
8.0 kV air,
4.0 kV contact,
RF Susceptibility
EN 61000-4-3
2
1kHz sine wave, 80% AM
10 V/m, 80 – 1000 MHz
3 V/m, 1.0 – 2.0 GHz
1 V/m, 2.0 – 2.7 GHz
Fast Transient
EN 61000-4-4
2
DC Input:
2 kV, 33 nF direct
Video and Ethernet ports, shielded:
1.1 kV, capacitive clamp
RS-232 port, unshielded:
1.1 kV, capacitive clamp
Surge
EN 61000-4-5
2
DC Input: 0.5 kV, 12 ohms (CM); 0.5 kV, 2 ohms (DM)
Ethernet port, shielded: ±1.0 kV, 2 ohms (CM)
Conducted RF Immunity
EN 61000-4-6
2
DC Input: 10 V, CDN
Video and Ethernet ports, shielded:
10 V, current clamp
RS-232 port, unshielded:
10 V, current clamp
Magnetic Field Immunity
1
EN61000-4-8
50 and 60 Hz, 30 A/m
Damped Oscillatory Wave
EN 61000-4-18
2
DC Input:
2. 5kV, 1 MHz (CM/DM);
Video and Ethernet ports, shielded:
2.5 kV, 1 MHz (CM)
RS-232 port, unshielded:
2.5 kV, 1 MHz (CM)
1)
Applies only to IPCs with magnetic hard drive (ICRXIBNxM00xA).
2)
EN 61000-4-x series of tests are technically equivalent to the IEC 61000-4-x series.