DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL
Page 43
October 1998
PUMP
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-128
Armature current is greater than 300A
for longer than 70 seconds
This status code is displayed when armature current is
maintained at a level above 300A for >70 seconds.
MEMORY RECALL
YES
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM:
Pump contactor opens
and closes, then can
only be closed by
opening and closing the
key switch.
POSSIBLE CAUSE:
Discharged battery
•
=
Check battery to insure
proper state of charge.
Loose connection at P1.
•
=
Insure that the wire
connection at PB1 is
tight.
Defective controller unit.
•
=
Replace control.
P1
P2
P10
P6
P5
P16
94 INPUT
94 INPUT
90 INPUT
P13
P11
91 INPUT
BRUSHWEAR OUTPUT - PY9
P14
OVER TEMP OUTPUT - PY8
P15
92 INPUT
P12
P9
95 INPUT
P8
95 INPUT
LINE
P19
P20
P21
P4
P3
93 INPUT
93 INPUT
TO TRACTION
CARD
SPEED LIMIT 1
SPEED LIMIT 2
SPEED LIMIT 3
SPEED LIMIT 4
TO
TRACTION
P10 - BDI
PY7
PY12
PY10
PY11
SERI
A
L RECEI
V
E
SERIAL TRANSMIT
+5V FROM
TRACTION PY10
P17
P18
ACC POT
POWER CONNECTIONS
POS
A1
NEG
FIELD
ARMATURE
FU1
+
-
FU5
KEY SWITCH
FU6
L
1A
A2
1A
PUMP
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-141
Open thermal protector (TP1) or
transistor is over temperature.
This status code is displayed when the internal
heatsink temperature of the control exceeds 90
degrees.
MEMORY RECALL
NO
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM:
Reduced or no power to pump motor in
control range.
POSSIBLE CAUSE:
Control is in thermal cut-back.
•
=
Allow control to cool, status code
should disappear.
•
=
If control cools to ambient
temperature and the fault remains
when the control is restarted, replace
the control.
NO
GRAPHIC
FOR THIS
STATUS CODE