– 36 –
Knob Index / Test
number (Displayed
on SSD, 7-segment
display, if present)
(Without SSD will be
displayed in binary
format. (See Binary
Chart)
Test Name
Description of test
If tests call for numbers to be shown it will: (Display on SSD,
7-segment display, if present.) (Without SSD will be displayed in
binary format. (See Binary Chart) Turning the cycle knob will index
to the next or prior test.
4
UI
Software
Version
(Non-
critical)
After entering this test, press the Start button to toggle through the
software version number as follows:
Example: v01.23
High end UI (Seven Segment Display)
1st press - "01" on SSD
2nd press - "23" on SSD
Low end UI (Cycle Status LED Lights)
Major version (Pause LED ON)
1st press - Display 0 in binary (all LEDs off)
2nd press - Display 1 in binary
Minor version (Lid Locked LED ON)
3rd press - Display 2 in binary
4th press - Display 3 in binary
5
XML
Version
(Non-
critical)
Example: v01.23
High end UI (Seven Segment Display)
1st press - "01" on SSD
2nd press - "23" on SSD
Low end UI (Cycle Status LED Lights)
Major version (Pause LED ON)
1st press - Display 0 in binary (all LEDs off)
2nd press - Display 1 in binary
Minor version (Lid Locked LED ON)
3rd press - Display 2 in binary
4th press - Display 3 in binary
NOTE: We only show the non-critical version number because the
critical XML version number must match the application non-critical
version number for the control to boot. If you get to service mode,
then the XML critical version is correct. If not, update software.
6
Hot Water
Valve
Pressing Start will toggle the hot water valve on and off. Test will
have a time-out for how long valve will be on (1 minute). The valve
will turn off when the test is exited.
7
Cold Water
Valve
Pressing Start will toggle the cold water valve on and off. Test will
have a time-out for how long valve will be on (1 minute). The valve
will turn off when the test is exited.
8
Fabric
Softener
Dispenser
Pressing Start will toggle the fabric softener valve on and off.
Test will have a time-out for how long valve will be on (1 minute).
The valve will turn off when the test is exited.
9
Spray
Rinse Valve
Check
Pressing Start will toggle the spray rinse valve on and off. Test will
have a time-out for how long valve will be on (1 minute). The valve
will turn off when the test is exited.
(Continued next page)