Installation Instructions

REMOTE CONTROLLER INSTALLATION

LOCATION

• The controller should

be out of reach of small
children.

• Avoid locations where

the controller may
become hot (near the
oven or radiant heater).

• Avoid locations in direct

sunlight. The digital
display may be difficult
to read in direct
sunlight.

• Avoid locations where the remote controller

could be splashed with liquids.

• Do not install in locations where it can be

adjusted by the public.

CONFIGURATIONS

A maximum of 4 remote controllers can be
installed for a water heater or bank of water
heaters. Controllers can only be wired in parallel.
Controllers cannot be wired in series.

If 4 AGTRC1’s are installed, press the Priority and
On/Off buttons on the fourth controller until a beep
sounds.

CABLE LENGTHS AND SIZE

The cable for the remote controller should be
a nonpolarized two-core cable with a minimum
gauge of 22 AWG. The maximum cable length
from each controller to the water heater depends
on the total number of wired controllers connected
to the water heater.

Wire Controllers in Parallel

NUMBER OF WIRED

MAXIMUM CABLE LENGTH FOR EACH

CONTROLLERS

CONTROLLER TO WATER HEATER

1

328 ft. (100 m)

2

164 ft. (50 m)

3 or 4

65 ft. (20 m)

REMOTE CONTROLLER INSTALLATION
(cont.)

MOUNTING THE CONTROLLER

Determine a suitable location for
the controller.

Mount a single gang outlet box in the wall
where the remote control is indicated.

Run the cable between the controller
and the water heater or the controller
and the other controller.

Remove the face plate from the remote
controller, using a screwdriver.

Connect the cable to the remote controller.

Mount the controller to the wall in the single
gang outlet box installed in step 2.

Disconnect the power from the water heater.

Remove the cover of the water heater.

Remove the plastic cover from the PCB
and electrical connections.

WARNING:

DO NOT ATTEMPT

TO CONNECT THE REMOTE CONTROLLERS WITH
THE POWER ON.

Thread the cable through the access hole
at the base of the unit and connect the wires
to the controller terminals on the bottom
right-hand side of the PCB.

Secure the controller cable using the clamp
provided.

11

10

9

8

7

6

5

4

3

2

1

Outline of Remote

securing screw

1-21/32"

3-5/16"

securing screw

wiring hole

Summary of Contents for GN75DNSRSA

Page 1: ...r damages caused thereby SAFETY PRECAUTIONS WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids or other combustible materials in the vicinity of this or any other appliance To do so may result in an explosion or fire...

Page 2: ...s will not result in damage to the area adjacent to the appliance or to lower floors of the structure When such locations cannot be avoided it is recommended that a suitable drain pan adequately drained be installed under the appliance The pan must not restrict combustion airflow SAFETY PRECAUTIONS cont The flow of combustion and ventilation air shall not be obstructed This appliance is not suitab...

Page 3: ...trical Box Wire Nuts Concrete Wall Anchors Optional Your installation components may vary PARTS PROVIDED Locate the parts packed with the Water Heater Gas Valve 3 4 FNPT Ball Valve 4 10 x 11 4 Wood Screws OTHER TOOLS THAT MIGHT BE REQUIRED Hammer Drill with Concrete Bits Saw Threading Machine with Heads and Oiler Core Drill with Diamond Head Torch Set Copper Tubing Cutter Steel Pipe Cutter OTHER M...

Page 4: ...5 8 244 5 C Height Unit 227 8 582 D Height with brackets 251 2 647 7 E Hot Water Outlet from wall 35 8 91 F Hot Water Outlet from center 45 16 110 G Cold Water Inlet from wall 213 16 70 H Cold Water Inlet from center 11 8 27 I Gas Connection from wall 37 8 99 J Gas Connection from center 31 2 89 From base to gas connection 15 8 40 K From base to cold connection 2 50 From base to hot connection 15 ...

Page 5: ...or sags in horizontal vent runs by installing supports per the vent manufacturer s instructions Support horizontal vent runs every four feet and all vertical vent runs every six feet or in accordance with local codes Venting should be as direct as possible with a minimum number of pipe fittings Vent diameter must not be reduced Do not connect the venting system with an existing vent or chimney Do ...

Page 6: ...sembly I Clearance to service regulator vent outlet J Clearance to nonmechanical air supply inlet to building or 12 inches 30 cm the combustion air inlet to any other appliance K Clearance to a mechanical air supply inlet 3 feet 91 cm above if within 10 feet 3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property1 M Clearance under veranda porch deck or balco...

Page 7: ...RMINAL These clearances are applicable to both concentric terminations and nonconcentric vent exhaust terminations Local codes supersede these clearances Avoid termination locations near a dryer vent Avoid termination locations near commercial cooking exhaust ...

Page 8: ...Installation Instructions 8 FLUE INSTALLATION CONDENSATE DRAIN HORIZONTAL TERMINATION WITH VERTICAL TERMINATION condensate collector A CONDENSATE DRAIN required in all installations 3 in 75 mm minimum ...

Page 9: ...n must be used for hot water pipes below 36 due to burn risk to children NOTE It is recommended to install the bottom of the unit at least 18 off the ground to minimize blockage and maintenance from debris and provide room for the optional Pipe Cover Accessory Model Number AGTPCM NOTE Do not install electrical outlet directly below unit Electrical outlet must be installed less than 6 feet from uni...

Page 10: ...located at the top and bottom of the water heater Ensure that the attachment strength is sufficient to support the weight Refer to the weight of the water heater in the Specification Guidelines Four mounting screws with 200 lb tensile load capability are required at a minimum 3 2 1 Wall installation brackets CLEARANCES FOR WATER HEATER WARNING Combustible construction refers to adjacent walls and ...

Page 11: ...f engagement in wood should be used Screws should be rated to carry a tensile load of 200 lbs each Level the unit during installation NOTES Screws provided must fasten securely and directly into wood If screws go through drywall and do not fully engage the wood stud the installer must supply correct screws Do not hang the unit on drywall only The unit must be secured into wood mounting board 4 MOU...

Page 12: ... or an equivalent nonflammable solution as applicable Since some leak test solutions including soap and water may cause corrosion or stress cracking the piping shall be rinsed with water after testing unless it has been determined that the leak test solution is noncorrosive Always use approved connectors to connect the unit to the gas line Always purge the gas line of any debris before connection ...

Page 13: ...em Make sure the gas supply line to the water heater fits in the diagram shown on page 9 This is essential if a pipe cover accessory model number AGTPCM is to be installed IMPORTANT Use a pipe wrench to securely hold on to the end of the water heater gas inlet to prevent twisting the inlet IMPORTANT Leave the gas valve off until instructed to turn it on Gas Shut Off Valve Gas Supply Gas Pressure T...

Page 14: ... Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21 22 and or the standard Temperature Pressure Temperature and Pressure Relief Valves and Vacuum Relief Valves CAN1 4 4 3 WATER PIPING cont PRESSURE RELIEF VALVE cont The relief valve must be rated up to 150 psi and to at least the maximum BTU hr of the appliance The discharge from the pressure relief valve should be piped to the ground or in...

Page 15: ...to the water heater fit in the diagram shown on page 9 This is essential if a pipe cover accessory model number AGTPCM is to be installed SUPPLEMENTAL FREEZE PROTECTION If the unit is installed in an environment that can freeze follow state and local codes and apply heat trace to ALL water pipe and fittings located outside attic crawl space or building structure It is highly recommended in areas w...

Page 16: ...of the particular system being installed The drawing does not imply compliance with local building code requirements it is the engineer s contractor s responsibility to ensure the installation is in accordance with all local building codes Confer with local building officials before installation 3 4 Ball Valve 3 4 Union Pressure Relief Valve Boiler Drain Valve KEY NOTE If unit is installed in an e...

Page 17: ... the outside environment to prevent discharging water inside the building which can cause water damage NOTE If the unit is installed in an environment that can freeze follow state and local codes and apply heat trace to ALL water pipes and fittings located outside attic crawl space or building structure 17 Installation Instructions This is not an engineered drawing it is intended only as a guide a...

Page 18: ...TRICAL REQUIREMENTS This appliance must be supplied with 120V 60Hz and connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse If electrical supply provided does not meet the above specifications it is recommended that a licensed electrician install an approved outlet WARNING This water heater is equipped with a three prong grounding plug for ...

Page 19: ...t each VENTING INSTRUCTIONS Refer to the specific instructions on your vent product for additional installation requirements CONDENSATE Regions of cold climate will create more condensate in the vent system Condensate formation can even occur in high efficiency direct vent appliances To prevent condensate damage follow these instructions First remove the black plastic cap and use 5 8 ID flexible P...

Page 20: ...vent top to the water heater Lift up the female vent top and reposition as desired or replace with a male vent top Install the 4 screws at the vent top and tighten the 4 screws at the bracket Secure the first vent component to the water heater with one self tapping screw at the hole located above the condensate collector 5 4 3 2 1 Bracket MANUFACTURER PRODUCT PARTS Ubbink Rolux Vent System Refer t...

Page 21: ...i Connect Kit AGTCK1 and the Multi Connect Cable Kit AGTMC1 are optional accessories that connect 3 to 5 water heaters and allow them to function as one hot water source Refer to the instructions that come with the accessory for complete installation information GUIDELINES Do not install the Dual Connect Cable Kit AGTDC1 with the Multi Connect Kit AGTCK1 and the Multi Connect Cable Kit AGTMC1 beca...

Page 22: ...nected to the water heater Wire Controllers in Parallel NUMBER OF WIRED MAXIMUM CABLE LENGTH FOR EACH CONTROLLERS CONTROLLER TO WATER HEATER 1 328 ft 100 m 2 164 ft 50 m 3 or 4 65 ft 20 m REMOTE CONTROLLER INSTALLATION cont MOUNTING THE CONTROLLER Determine a suitable location for the controller Mount a single gang outlet box in the wall where the remote control is indicated Run the cable between ...

Page 23: ...T outlet and COLD inlet water lines to ensure they have not been crossed and are leak free Ensure the manual gas valve packaged with the water heater is installed in the gas supply line see page 12 Ensure the controller is installed and functioning Instruct the consumer on how to operate the controller Instructions are always supplied in the Owner s Manual see page 22 A typical water temperature s...

Page 24: ...24 Installation Instructions TECHNICAL DATA PRESSURE DROP CURVE OUTLET FLOW DATA GN75 GN94 GP94 GN75 GN94 GP94 ...

Page 25: ...LADDER DIAGRAM 25 Installation Instructions ...

Page 26: ...26 Notes ...

Page 27: ...27 Notes ...

Page 28: ...28 Notes ...

Reviews: