background image

10

About the water filtration system.

Filter Cartridge Installation or Replacement

CAUTION:

Never remove the sumps when water

pressure is in the Water Filtration system.

Close the water supply/saddle valve to the filter.

(See illustration in the 

Installation Overview

section for location of the water supply valve.)
Open the filtered water faucet.

Remove the sump, using the sump wrench tool
provided, from the filter head by rotating the
sump as shown in the below illustration. 
Be careful, the sump may be full of water. 
Be sure to keep the large o-ring seal.

If you are replacing a filter cartridge, remove 
and discard the used filter cartridge.

Be sure the inside of the sump is clean.
Thoroughly wash the inside of the sump 
with hot, soapy water and rinse.

Remove the wrapper from the new filter
cartridge and insert the filter cartridge in the
sump. Some cartridges fit either way, while 
others fit only one way. Observe markings on 
the cartridge.

NOTE: 

The Water Filtration system may use two

different types of filter cartridges. Be sure to
install them correctly. 

Filter I

cartridge should

always be placed in the 

Filter I

sump. 

Filter II

cartridge should always be placed in the 

Filter II

sump. See page 3 for a complete list of filter
performance characteristics.

5

4

3

2

1

Filter I 

Filter II

O-ring seal

Cartridge

Sump II

Sump

Sump I

Label

TURN SUMP 

TO INSTALL

TURN SUMP 

TO REMOVE

Head

Bracket

Turn sump wrench tool
provided clockwise to
remove sump

OUTLET

INLET

For Model GN1S15CBL
(rev. 2)

FXULC (rev. 2) Filter
(600-Gallon Capacity)

Filter

– White with

yellow end caps

For Model GNSL05CBL
(rev. 2)

FXSLC (rev. 2) Filter
Set 
(600-Gallon Capacity)

Filter I

– White with no

end caps 

Filter II

– White with

yellow end caps

For Models GNSV25CBL,
GNSV30CWW &
GNSV30CCC

FXSVC (rev. 2) Filter Set 
(600-Gallon Capacity)

Filter I

– White with

green end caps 

Filter II

– Gray

Summary of Contents for GN1S15CBL (REV. 2)

Page 1: ...CCC GNSL05CBL rev 2 GN1S15CBL rev 2 Owner s Manual and Installation Instructions Water Filtration 215C1001P019 3 49 50057 3 05 02 JR 7239707 Safety Instructions 2 Operating Instructions Specification Guidelines 3 Using the System 4 Installation Instructions 5 11 Battery Pack Installation 8 Faucet Installation 7 8 Feed Water Supply 6 Filter Cartridge Installation or Flush Procedure 10 11 Important ...

Page 2: ...wed to minimize the risk of property damage or personal injury SAFETY PRECAUTIONS Check with your local public works department for plumbing codes You must follow these guidelines as you install the Water Filtration system Use the Water Filtration system on a potable safe to drink home COLD water supply only The filter cartridges will not purify the water or make it safe to drink Do not use on a h...

Page 3: ...astes and odors Reduces Chlorine Taste and Odor Reduces Lead Reduces Asbestos Reduces filterable cysts such as cryptosporidium and giardia Reduces Lindane a pesticide Reduces Turbidity Reduces Mercury Reduces Atrazine 0 5 1 micron nominal particulate reduction For Models GNSV25CBL GNSV30CWW and GNSV30CCC FXSVC rev 2 Filter Set 600 Gallon Capacity Filter I White with green end caps Filter II Gray R...

Page 4: ...ed immediately If the system is also for lead or chemical contaminant removal it is MORE IMPORTANT to replace the cartridges at least every six months NOTE If the water supply contains high amounts of sediments the carbon filters may plug prematurely reducing filtered water flow to the system faucet Cartridge replacement is needed to restore flow Electronic Indicator Light not available on all mod...

Page 5: ...saddle valve installation Electric drill and drill bit to drill 1 1 1 4 hole type as required if mounting hole is needed for faucet CAUTION To avoid damaging the sink consult a qualified plumber or installer for drilling procedures Special drill bits may be needed for porcelain or stainless steel Contents included with the product Water filter assembly including mounting bracket and screws Product...

Page 6: ...use plumbing code 248 CMR of the Commonwealth of Massachusetts Turn off the cold water supply and attach saddle valve as shown in illustration at right DANGER To protect yourself from serious injury or fatal shock use a battery powered hand drill only to make the hole DO NOT USE AN ELECTRIC DRILL Close the water supply valve by turning the handle clockwise Open the main water supply valve and seve...

Page 7: ...gasket base and large gasket in that order onto the faucet stem Next place lock washer and hex nut onto faucet stud Insert washer into tubing adapter Securely tighten to faucet stud Feed the length of 3 8 OD tube from the bottom up through the mounting hole Connect to the tubing adapter as shown in second illustration tightening the compression nut securely Remove the short shipping tube and inser...

Page 8: ...e base is held firmly in place Do not overtighten and break the base Assemble the top faucet base and hex nut onto the faucet stud third illustration Tighten the nut until snug Insert tubing insert into tubing adapter Securely tighten to faucet stud Feed the length of 3 8 OD tubing from the bottom up through the faucet base Connect to the tubing adapter as shown in fourth illustration tightening t...

Page 9: ...ng Insert the plastic tubing all the way to the bottom of the elbow Tubing must be fully inserted to avoid leaks Slide nut up to the elbow and thread on by hand until tight Repeat the procedure to connect the tubing between the filter system inlet and the water supply saddle valve illustration in the Installation Overview section IMPORTANT Be sure to check for leaks at all connections Tighten as n...

Page 10: ...filter cartridge in the sump Some cartridges fit either way while others fit only one way Observe markings on the cartridge NOTE The Water Filtration system may use two different types of filter cartridges Be sure to install them correctly Filter I cartridge should always be placed in the Filter I sump Filter II cartridge should always be placed in the Filter II sump See page 3 for a complete list...

Page 11: ...he sump will not tighten up to the head or if you feel resistance you may have the cartridge in upside down or misaligned Take the cartridge out and check for correct orientation or alignment and reassemble Repeat steps 2 through 8 for the Filter II cartridge in the Filter II sump if necessary Turn on the filtered water faucet Then slowly open the water supply saddle valve and allow the filter hou...

Page 12: ...nd install replaced or they may have been correctly Replace batteries if they are old installed incorrectly Lead wires damaged Inspect and repair as needed Chlorine taste and or The filter cartridges are no Replace both filter cartridges odor in the product water longer removing chlorine from the water supply Water dispenses Filter may have an integral A slower flow approx 0 6 g min is normal with...

Page 13: ...CET ASM monitored BISQUE 1 0019 WS10X10008 TOP FAUCET BASE BLACK 1 1 WS10X10010 TOP FAUCET BASE WHITE 1 WS10X10022 TOP FAUCET BASE BISQUE 1 0020 WS02X10007 SCREW 6 32 X 1 3 8 2 2 2 2 0021 WS10X10002 BASE FAUCET KIT BLACK 1 1 WS10X10221 BASE FAUCET KIT WHITE 1 WS10X10027 BASE FAUCET KIT BISQUE 1 0022 WS02X10008 NUT 2 2 2 2 0023 WS08X10003 GASKET FAUCET 1 1 1 1 0024 WS06X10001 HOLDER BATTERY 1 1 1 1...

Page 14: ...X10044 TUBING ADAPTER ASM 2 0017 WS15X10008 SADDLE VALVE SUPPLY 1 0018 WS15X10022 FAUCET ASM nonmonitored BLACK ON CHROME 1 0025 FXULC rev 2 FILTER LEAD CYST 1 0200 WX5X140 WRENCH SUMP 1 0999 49 50057 PM MANUAL USE CARE INSTALLATION 1 14 Saddle Valve General Electric parts catalog Parts List NOTE Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the u...

Page 15: ...ogically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts Filter cartridges Replacement of house fuses or resetting of circuit breakers Damage to the product caused by accident fire floods or acts of God Incidental or consequential damage caused by possible d...

Page 16: ... and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to the...

Reviews: