– 30 –
Self Diagnostic Mode
Self Diagnostic Mode
will not display errors and other information available in
Service Mode.
It does allow
for up to 60 minutes of wash pump and heater operation. Service Mode should be run before entering Self
Diagnostic Mode.
To enter the
6HOI'LDJQRVWLF0RGH
1. Cancel any cycle started (including
Delay Start
), and make sure that the dishwasher is in a standby or
LGOHVWDWH7KHGUDLQSXPSPXVW¿QLVKDVHFRQGUXQSHULRG
2. Disconnect power to the dishwasher for 30 seconds.
3. Within 3 minutes of reconnecting power, open the door and hold both the
Select
and
Start/Reset
pads
PXVWEHFRPSOHWHGZLWKLQVHFRQGV$OO/('VDQG66'ÀDVKDWUDWHRIVHFRQG
4. Close the door. If the door is opened during the diagnostic procedure, closing the door will restart the
test.
All cycle LED’s, Clean LED and Rinse LED will turn off, and display machine type for 2 seconds; then proceed
WRWKH¿UVWVWHS3UHVVLQJF\FOHVHOHFWGXULQJDQ\VWHSRIWKLVPRGHZLOODGYDQFHWKHFRQWUROWRWKHQH[WVWHS
when door closed. If the door is opened during this mode, the loads will stop immediately. The loads will
restart when the door is reclosed.
In step 4 (table below) if the temperature doesn't reach 122°F within 60 minutes, the error code "E3" will be
displayed on the SSD. If the temperature does reach 122°F, the load will stop and advance to step 5.
To exit the self diagnostic mode, disconnect the power.
*Subject to change with future development.
Step
Component
SSD
Time or Temperature
0
Machine Type
C9*
3 seconds
1
Fill Valve
09
61 seconds
2
Wash Pump
08
3 minutes
3
Dispenser
07
60 seconds
4
Wash Pump and Heater
06
60 minutes or 122°F
5
Drain Pump
05
60 seconds
6
All Load Off
04
15 seconds
7
Fill Valve
03
61 seconds
8
Wash Pump
02
180 seconds
9
Drain
01
60 seconds
10
Buzzer beep and End
F_
Software Version, beeper 1/2 second
Summary of Contents for GLDT690J__BB
Page 31: ... 31 Schematic CONTROLLER ...