Copyright 2011
89
Inlet Control Thermistor
Inlet Control
Thermistor
Operation of the inlet control thermistor
can be checked by using service
test mode T06.
Specific failures associated with the inlet control thermistor
can initiate
error codes E3 and E4.
To remove the inlet control
thermistor:
1. Remove the drum.
2. Disconnect the 2 wires from
the inlet control thermistor.
3. Remove the Phillips-head
screw that attaches the inlet
control thermistor
to the heater
assembly or diffuser.
4. Lift and slide the thermistor
from the heater assembly or
diffuser.