Gas Valve Coils
The burner assembly has a gas
valve that utilizes 3 coils.
A double coil (safety and booster
coils combined) and a single main
coil are located on top of the gas
valve in front of the combustion
chamber opening.
All coils can be replaced separately.
Gas valve coil assembly resistance
values:
•
Safety coil terminals -
1400
Ω
•
Booster coil terminals -
580
Ω
•
Main coil terminals -
1300
Ω