49-6000121 Rev. 0
LOCAL INSTALLATION
REGULATIONS
This water heater must be installed in accordance
with these instructions, local codes, utility codes,
utility company requirements or, in the absence of
local codes, the latest edition of the National Electrical
Code. It is available from some local libraries or
can be purchased from the National Fire Prevention
$VVRFLDWLRQ%DWWHU\PDUFK3DUN4XLQF\0$DV
ERRNOHW$16,1)3$
The solar energy system shall comply with building
code, plumbing code, mechanical code, and fire code
adopted by the authority having jurisdiction or, in the
absence of such codes, with the International Building
Code, International Plumbing Code, International
Mechanical Code, and International Fire Code.
Installation Instructions
RELIEF VALVE
CAUTION
RISK OF UNIT DAMAGE - THE
PRESSURE RATING OF THE RELIEF VALVE
MUST NOT EXCEED 60 PSI (413.6 KPA), THE
MAXIMUM WORKING PRESSURE OF THE
WATER HEATER AS MARKED ON THE RATING
PLATE.
$OLVWHGDQGODEHOHGSUHVVXUHUHOLHIYDOYHFRPELQHG
non-return/safety valve) is supplied and must remain
installed in the opening provided and marked for the
purpose on the water heater. No valve of any type
should be installed between the relief valve and the
WDQN/RFDOFRGHVVKDOOJRYHUQWKHLQVWDOODWLRQRI
relief valves.
7KH%78+UDWLQJRIWKHUHOLHIYDOYHPXVWQRWEH
less than the input rating of the water heater as
LQGLFDWHGRQWKHUDWLQJODEHOORFDWHGRQWKHKHDWHU
ZDWW %78+
Connect the outlet of the relief valve to a suitable
open drain so that the discharge water cannot
contact live electrical parts or persons and to
eliminate potential water damage.
Piping used should be of a type approved for hot
water distribution. The discharge line must be no
smaller than the outlet of the valve and must pitch
downward from the valve to allow complete drainage
E\JUDYLW\RIWKHUHOLHIYDOYHDQGGLVFKDUJH
line. The end of the discharge line should not be
threaded or concealed and should be protected from
freezing. No valve of any type, restriction or reducer
coupling should be installed in the discharge line.
RELIEF VALVE (Cont.)
CAUTION
RISK OF SCALD AND
PROPERTY DAMAGE
To reduce the risk of excessive pressures in this
water heater, install pressure protective equipment
required by local codes and no less than a pressure
relief valve certified by a nationally recognized
testing laboratory that maintains periodic inspection
of production of listed equipment or materials.This
valve must be marked with a maximum set pressure
not to exceed the marked maximum working
pressure of the water heater. Install the valve into
an opening provided and marked for this purpose
in the water heater, and orient it or provide tubing
so that any discharge from the valve exits only
ZLWKLQLQFKHVDERYHRUDWDQ\GLVWDQFHEHORZ
the structural floor, and does not contact any live
electrical part. The discharge opening must not be
blocked or reduced in size under any circumstances.
INST
ALLA
TION INSTRUCTIONS
Summary of Contents for GeoSpring GT50C10BAM
Page 39: ...49 6000121 Rev 0 CERTIFICATION THIS PAGE INTENTIONALLY LEFT BLANK SRCC OG 300 Certification...
Page 41: ...49 6000121 Rev 0 CERTIFICATION THIS PAGE INTENTIONALLY LEFT BLANK SRCC OG 300 Certification...
Page 43: ...49 6000121 Rev 0 43 CERTIFICATION THIS PAGE INTENTIONALLY LEFT BLANK SRCC OG 300 Certification...
Page 45: ...49 6000121 Rev 0 45 CERTIFICATION THIS PAGE INTENTIONALLY LEFT BLANK SRCC OG 300 Certification...
Page 47: ...49 6000121 Rev 0 NOTES Notes...