Important Safety Warnings
• Installation should be made by a qualified service person and should
conform to all local codes.
• DO NOT bundle UTP signals in the same conduit as high-voltage wiring.
• To reduce the risk of fire or electrical shock, do not expose these products to
rain, moisture, dripping or splashing.
• No objects filled with liquids, such as vases, shall be placed on GE equipment.
• DO NOT block ventilation openings to let sufficient airflow to the UTP devices.
• The Main fuse for models with built-in AC power supply is 5 A at 110 VAC or
at 3 A 220 VAC. Each camera power fuse is 2 A and can be accessed by
removing the front panel. Fuses may be replaced by a qualified service
person only when the unit is off and AC power cord is unplugged.
• Use only the power cord and plug supplied with the unit for connecting to AC
outlets.
• Only unplugging the power cord is considered as a main power disconnect.
• DO NOT connect multiple outputs together.
• Make sure that the mains Voltage input is set to the proper local voltage.
Wiring Technical Notes
These technical notes should all be considered prior to installing these devices.
• Use point to point unshielded twisted pair wire 24-16 AWG (0, 5-1, 3 mm)
stranded or solid, Category 2 or better.
• The video signal may coexist in the same wire bundle as other video,
telephone, data, control signals, or low-voltage power. You can run GE video
signals in or near electromagnetic fields (in accordance with National
Electrical Code, local or other local safety requirements).
• DO NOT USE SHIELDED TWISTED PAIR WIRE. Multi-pair (8 pair or more) wires
with an overall shield are fine.
• DO NOT USE UN-TWISTED WIRE.
• DO NOT place a transmit and a receive signal in the same wire bundle. It
may cause interference.