Introduction 

GE Security Multi-Channel VPD Combiners combine video, PTZ data, and camera 
power over a single 4-pair UTP cable to simplify CCTV installations in a structured 
wiring environment. They support up to 16 cameras.   The GEC-8VPDCHUB and 
the GEC-16VPDCHUB models come with built-in AC power supplies. They receive 
110/220 VAC power and provide up to 16 ports of 24/28 VAC isolated power to 
the cameras.  Each port is individually equipped with a resettable fuse plus a 2A 
glass fuse that is easily accessible from front.  

For short runs install the GEC-16VPDCHUB close to the video receiver unit at the 
control end. For long runs place the GEC-8VPDCHUB or GEC-16VPDCHUB at a 
mid span point close to the camera end to minimize the loss of voltage over 
twisted pair. 

The following model numbers are covered in this document: 

• GEC-4VDPC 

• GEC-16VDPC 

• GEC-8VPDCHUB 

(powered) 

• GEC-16VPDCHUB 

(powered) 

Summary of Contents for GEC-16VDPC

Page 1: ...t in AC power supplies They receive 110 220 VAC power and provide up to 16 ports of 24 28 VAC isolated power to the cameras Each port is individually equipped with a resettable fuse plus a 2A glass fuse that is easily accessible from front For short runs install the GEC 16VPDCHUB close to the video receiver unit at the control end For long runs place the GEC 8VPDCHUB or GEC 16VPDCHUB at a mid span...

Page 2: ...as been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture This apparatus shall not be exposed to dripping or splashing ...

Page 3: ...ed Use only the power cord and plug supplied with the unit for connecting to AC outlets Only unplugging the power cord is considered as a main power disconnect DO NOT connect multiple outputs together Make sure that the mains Voltage input is set to the proper local voltage Wiring Technical Notes These technical notes should all be considered prior to installing these devices Use point to point un...

Page 4: ...dard Measure wire distance by 1 Shorting the two conductors together at the far end and measuring the loop resistance by an Ohmmeter 2 Use the Loop Resistance table to calculate the distance DO NOT connect coax cables longer than 100 ft 30 M to the BNC connectors of any GE UTP equipment All measured distances should include any coax cables in the path Verify camera current requirements and wire re...

Page 5: ... 448 ft 137 m 896 ft 273 m 2 388 ft 728 m 100 mA Camera Dual 23 AWG 564 ft 172 m 1 130 ft 345 m 3 012 ft 918 m Dual 24 AWG 150 ft 46 m 300 ft 92 m 796 ft 243 m 300 mA Camera Dual 23 AWG 190 ft 58 m 378 ft 115 m 1 004 ft 306 m Dual 24 AWG 46 ft 14 m 90 ft 28 m 240 ft 73 m 1 AMP Camera Dual 23 AWG 58 ft 18 m 114 ft 35 m 300 ft 92 m Application Drawings GEC 4VDPC GEC 16VDPC ...

Page 6: ...rn off external power supply Video Connect each RJ 45 video connector to a Cat 5 cable carrying 4 video signals to the control room Data Connect each RJ 45 data connector to a Cat 5 cable carrying 4 data signals to the control room Camera Cable Connect each camera RJ 45 connector to the appropriate camera Cat 5 cable ...

Page 7: ...a RJ 45 connector to the appropriate camera Cat 5 cable Power Make sure that the power requirement is within the recommended range Connect the AC power cord to the AC power outlet and turn on the power switch to the unit Control Room Installation Video Connect each Cat 5 cable carrying 4 video signals to the Active Receiver Hub If Cat 5 is terminated in RJ 45 use provided RJ 45 adapter for the con...

Page 8: ...LED OFF Fuse is blown or not installed ON Fuse is OK power is available at RJ45 connector EIA TIA 568A B Color Codes Midspan Control Room Video Connections GEC 4VDPC GEC 16VDPC GEC 8VPDCHUB and GEC 16VPDCHUB Camera 1 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 GEC 16VDPC and GEC 16VPDCHUB Camera 9 16 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ...

Page 9: ... 100 Ohms 20 24 AWG min unshielded Category 2 7 up to 750 ft 228m Power Protection One self resetting fuse at 1 5 A per channel Input Voltage Pass through GEC 4VDPC GEC 16VDPC 115 230 VAC 50 60 Hz externally switch selectable Input Current 2 4 A at 115 VAC 1 2 A at 230 VAC GEC 8VPDCHUB 4 8 A at 110 VAC 2 4 A at 220 VAC GEC 16VPDCHUB Camera Power Voltage Isolated class II individually switch select...

Page 10: ... metal GEC 16VPDCHUB Extruded Aluminum and sheet metal Dimensions W x H x D GEC 4VDPC 4 97 x 1 74 x 177 in 12 6 x 4 4 x 4 5 cm GEC 16VDPC 18 x 1 74 x 1 77 in 46 x 4 4 x 4 5 cm GEC 8VPDCHUB 17 x 1 74 x 10 5 in 43 x 4 4 x 26 6 cm GEC 16VPDCHUB 17 x 1 74 x 10 5 in 43 x 4 4 x 26 6 cm Weight GEC 4VDPC 0 44 lb 198 g GEC 16VDPC 1 37 lb 620 g GEC 8VPDCHUB 14 7 lb 6 6 kg GEC 16VPDCHUB 22 lb 10 kg Environme...

Page 11: ...nufacturer GE Security Inc HQ and regulatory responsibility GE Security Inc 8985 Town Center Parkway Bradenton FL 34202 USA EU authorized manufacturing representative GE Security B V Kelvinstraat 7 6003 DH Weert The Netherlands Regulatory information N4131 Note C Tick mark applies to GEC 4VDPC and GEC 16VDPC only North American standards UL 60065 ...

Page 12: ...ermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV tech...