![GE GDF510PxJ Series Technical Service Manual Download Page 60](http://html1.mh-extra.com/html/ge/gdf510pxj-series/gdf510pxj-series_technical-service-manual_4266970060.webp)
– 60 –
The adjustable conduit has an internal check valve
to block wash water from exiting the wash system,
keeping water directed into mid spray arm. The mid
conduit is replaced as an assembly, individual parts
for the assembly are not available separately.
Some models have a port on the right side to allow
ZDWHUÀRZWRWKHERWWOHZDVKIHDWXUH
Lower Spray Arm
The Lower Spray Arm provides an upward directed
ZDWHUÀRZZKLFKWXUQVFORFNZLVHZKHQLQ
operation. The arm, bearing, and nut come as a
complete assembly and has a twist lock design. To
remove, turn the nut counter clockwise. Only the
lower spray arm has heat shields.
Middle Spray Arm
The Mid Spray Arm provides an upward directed
spray pattern to the upper rack. To remove the mid
spray arm, turn the nut clockwise (looking down
through the upper rack).
Middle Conduit
The Mid-level Conduit supplies water from the
main conduit to the mid spray arm and bottle
wash feature (some models). Some models have
adjustable racks. An adjustable conduit is used to
allow proper engagement of the main conduit to the
mid conduit.
Mid Conduit for Adjustable Upper Racks
Mid Conduit for Non-Adjustable Upper
Racks
Cover
Gasket Check Valve Main Conduit Body
Bottle Wash Hose Cover
Bottle Wash Supply Hose
Mid Conduit Bottle Wash Port
Summary of Contents for GDF510PxJ Series
Page 19: ...19 Silverware Basket on Door Silverware Basket in Bottom Rack...
Page 46: ...46 Diagnostics Strip circuit...
Page 63: ...63 Diagnostics Drain Pump Strip Circuit...
Page 68: ...68 Schematics GDF520J GDF610J...
Page 69: ...69 GDT535J...
Page 70: ...70 ADT521J GDF610J GDF620J GDT545J GDT625J GDT635J...
Page 72: ...72 Upper Spray System 5 8 61 V Vent Parts 4 33 W Warranty 72 Water Level 4 45...