![GE GDF510PxJ Series Technical Service Manual Download Page 40](http://html1.mh-extra.com/html/ge/gdf510pxj-series/gdf510pxj-series_technical-service-manual_4266970040.webp)
– 40 –
Service Mode
Entering Service Mode
NOTE: Entering Service Mode resets the CSM.
The dishwasher must be in Consumer Error Mode
to enter Service Mode. Entering Service Mode will
reset the CSM, allowing loads to be checked for the
cause of the CSM to trip. The control will blink the
Normal LED (light on model GDF510PxJxx) every few
seconds for the number of times corresponding to
the load being tested.
While in Consumer Error Mode:
• Press and hold Cycle Select pad for 5 seconds.
• Press Cycle Select to select or increment each
test.
• Press Start, to start and stop each test.
Service Mode will exit after 5 minutes of Inactivity.
Exit Service Mode by pressing and holding Cycle
Select and Start pads for 5 seconds.
Diagnosing Electronic Control Boards
Diagnosing the main control and UI control are
covered in this section. Many components can
be checked from the main control, which can be
accessed with the door on or removed if needed.
Some connectors are located through the bottom
cover to allow easy access to AC supply connector,
door harness and ACM or Appliance Control Module.
The ACM or Smart Appliance allows the appliance to
communicate with the utility meter when peak rates
occur, and allows the appliance to respond and
operate in a manner that will reduce energy usage
of that appliance at high/critical demand rates. For
more on the module and display, refer to Smart
Appliance documents.
WARNING: GE Factory Service Technicians are
REQUIRED to follow Lockout / Tagout (LOTO) 6
Step Process prior to beginning repair.
LED
Blink #
Load to
Control
Timeout / Notes
1
Drain Pump
Attempts to empty. Takes
approximatly 75 seconds
from normal level.
2
Water Valve
$WWHPSWVWR¿OOWRQRUPDO
level. Takes approximatly 1
minute.
3
Circulation
Pump
Runs for approximatly 2
minutes, alternating lower
spray arm to mid and
upper spray systems every
30 seconds.
4
Heater
Turns on heater for a
maximum of 2 minutes.
5
Detergent
Module
Turns on detergent module
solonoid for a maximum of
2 minutes.
Heat
Connector
AC Power Connector (backside of board)
DC Power
Connector
Service
LED
Drain & Circ. Connector
Personality
Jumper
Summary of Contents for GDF510PxJ Series
Page 19: ...19 Silverware Basket on Door Silverware Basket in Bottom Rack...
Page 46: ...46 Diagnostics Strip circuit...
Page 63: ...63 Diagnostics Drain Pump Strip Circuit...
Page 68: ...68 Schematics GDF520J GDF610J...
Page 69: ...69 GDT535J...
Page 70: ...70 ADT521J GDF610J GDF620J GDT545J GDT625J GDT635J...
Page 72: ...72 Upper Spray System 5 8 61 V Vent Parts 4 33 W Warranty 72 Water Level 4 45...