– 41 –
Blink Pattern
Meaning
1x per 3 seconds Dishwasher in not running a
cycle, select a cycle and press
Start.
2x per 3 seconds Dishwasher is in Delay Start
and waiting to start a cycle.
The cycle will begin once the
delay expires.
3x per 3 seconds Dishwasher is running a cycle.
4x per 3 seconds Dishwasher is paused, close
the door and press Start to
resume the cycle.
5x per 3 seconds Dishwasher has completed a
cycle and the Clean Light is on
(door has not been opened).
6x per 3 seconds Dishwasher is in Demo Mode.
To exit Demo Mode, press and
hold Start and Heated Dry for
5 seconds.
7X per 3 seconds Current Sense Module is
tripped. See the CSM section of
this guide.
1x per second
Communications lost between
control boards. Check
connections, replace UI or MC
as needed.
Flashing rapidly
(4x per second)
Software error, replace MC.
6WHDG\RȺ
Dishwasher is not powered,
check supply voltage, replace
MC as needed.
Steady On
UI personality not set,
communications lost between
UI and MC.
Main Control Diagnostics
Diagnostics are aided with the addition of a green
Service LED on the machine control board that
indicates the status of the control board. To view the
LED, disconnect power and place the main control
in service position (see the To Access Main Control
Board section), then repower the dishwasher to view
the Service LED.
Summary of Contents for GDF510PxJ Series
Page 19: ...19 Silverware Basket on Door Silverware Basket in Bottom Rack...
Page 46: ...46 Diagnostics Strip circuit...
Page 63: ...63 Diagnostics Drain Pump Strip Circuit...
Page 68: ...68 Schematics GDF520J GDF610J...
Page 69: ...69 GDT535J...
Page 70: ...70 ADT521J GDF610J GDF620J GDT545J GDT625J GDT635J...
Page 72: ...72 Upper Spray System 5 8 61 V Vent Parts 4 33 W Warranty 72 Water Level 4 45...