2
GROUNDING REQUIREMENTS
Improper connection of the equipment
grounding conductor can result in a risk of electrical shock. Check
with a licensed electrician if you are in doubt as to whether the
appliance is properly grounded.
1.
The washer
MUST
be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electrical
shock by a path of least resistance for electrical current.
2.
Since your washer is equipped with a power supply cord
having an equipment-grounding conductor and a grounding
plug, the plug
MUST
be plugged into an appropriate, copper
wired receptacle that is properly installed and grounded in
accordance with all local codes and ordinances or in the
absence of local codes, with the National Electrical Codes,
ANSI/NFPA 70 (latest edition). If in doubt, call a licensed
electrician.
DO NOT
cut off or alter the grounding prong on
the power supply cord. In situations where a two-slot
receptacle is present, it is the owner’s responsibility to have
a licensed electrician replace it with a
properly grounded
three prong grounding type receptacle.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets
MUST
be installed within 42 inches
(107 cm) of your washer’s water inlet. The faucets
MUST
be 3/
4 inch (1.9 cm) garden hose type so inlet hoses can be
connected. Water pressure
MUST
be between 30 and 120
pounds per square inch (maximum unbalance pressure, hot vs.
cold, 10 psi.) Your water department can advise you of your
water pressure. The hot water temperature should be about
140 degrees F (60 degrees C).
DRAIN REQUIREMENTS
1.
Drain capable of eliminating 17 gals (64.3 L) per minute.
2.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3.
The standpipe height above the floor should be:
Minimum height:
24 in. (61 cm)
Maximum height:
96 in. (244 cm)
NOTE:
Drain hose attached to the washer can reach a 90 in. (229
cm) high standpipe. For higher standpipe, use hose P/N
134369410
, available from an authorized parts distributor.
PRE-INSTALLATION REQUIREMENTS
Tools Required for Installation:
1. Phillips screwdriver
2. 10 mm socket with ratchet.
3. Channel-lock adjustable pliers.
4. Carpenter’s level.
ELECTRICAL REQUIREMENTS
CIRCUIT
- Individual, properly polarized and grounded 15 amp.
branch circuit fused with 15 amp. time delay fuse or circuit
breaker.
POWER SUPPLY
- 2 wire, with ground, 120 volt, single phase,
60 Hz, Alternating Current.
NOTE:
The use of this washer with
power created by gas powered generators, solar powered
generators, wind powered generators or any other generator
other than the local utility company is not recommended.
OUTLET RECEPTACLE
- Properly grounded 3-prong receptacle
to be located so the power supply cord is accessible when the
washer is in an installed position.
24 in.
(61 cm)
Min.
96 in.
(244 cm)
Max.
BACK
NOTE:
GFI (Ground Fault Interrupter) receptacle is not required.
Before beginning installation, carefully read these instructions.
This will simplify the installation and ensure the washer is installed
correctly and safely. Leave these instructions near the washer
after installation for future reference.
NOTE: The electrical service to the washer must conform with
local codes and ordinances and the latest edition of the National
Electrical Code, ANSI/NFPA 70.
For your safety the information in this manual
must be followed to minimize the risk of fire or explosion or to
prevent property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and
liquid in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
·
Do not try to light any appliance.
·
Do not touch any electrical switch; do not use any phone in
your building.
·
Clear the room, building or area of all occupants.
·
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas suppliers instructions.
·
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.