background image

GE LIGHTING - ENTERTAINMENT LIGHTING CATALOGUE

0

Lamp caps

Typical caps used on the Photographic lamps listed in this catalogue are shown below along with
their IEC codes and normal names or common abbreviations. The IEC codes are used in the
majority of table entries. Note that the illustrations are not to scale.

R7s

G6.35    GY6.35

GZ6.35

G7.9 (std. volts)

GX7.9 (Low volts)

Ferrule Contact

Small Indexing Ring

(Ring is a full circle)

E26

E12/15

BA15d

P28/25

E39

5.5 mm

GY5.3 (Flat pins)

BA15s

P30s    P30d

P40s

Large Indexing Ring

(Ring is flat opposite pin)

Double Contact

Medium Ring

G17q    GX17q

G22

GX5.3 (Round pins)

2 button

GY9.5    GZ9.5

GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE

98

GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE

99

Lamp Comparison and Construction

Lamps for Ellipsoidal Spotlights

A problem is encountered with some ellipsoidal spotlight luminaires due to the fact that a portion of
the reflected beam of light is directed onto the cap of the lamp designed for Fresnel fittings. This
leads to overheating of the cap and seal which may result in premature lamp failure.

GE have therefore designed lamps intended for use in ellipsoidal spotlights where the size of the cap
has been reduced and the neck length correspondingly increased, thus removing the critical seal
area from the reflected radiation and ensuring that optimum lamp life is obtained.

Linear and ‘U’ Lamps - for Studio Lighting 3200K

Whilst a comprehensive selection of lamps for spotlight fittings is important to the lighting director,
of almost equal importance is a range suitable for the many different fittings now on the market
which use tungsten halogen lamps of tubular construction. GE believe their range gives a wide
choice and is unmatched in performance and reliability.

Summary of Contents for FEL

Page 1: ... marks of the General Electric Company USA General Electric Company USA 2003 www GELighting com S H O W B I Z F O R S T A G E S T U D I O D I S C O A N D P H O T O G R A P H I C L I G H T I N G S H O W B I Z F O R S TA G E S T U D I O D I S C O A N D P H O T O G R A P H I C L I G H T I N G e e ...

Page 2: ...novation and improvement to meet the demands and applications of O E M s and end users This updated catalogue shows those lamps from the extensive range of entertainment lighting products which are currently in popular use Please note the many new products including a more comprehensive range of discharge range Certain other USA manufactured lamp types may be available to special order Please cont...

Page 3: ...safety screen external to lamp F Operate BDTH G Operate BD 30 H 100V rating available to order J 120V rating available to order K Specially designed for searchlight applications L Twin filament lamp Lumen figures relate to single and twin filament options M Tungsten Halogen minimum bulb wall temp 250 C N 3 or 4 amp HBC fuse necessary P 5 or 6 amp HBC fuse necessary Q 6 or 7 amp HBC fuse necessary ...

Page 4: ...di Corriente de Einschaltstrom d Amorçage avviamento arranque Starting Time Temps Tempo di Tiempo de Startzeit sec d Amorçage sec accensione sec encendido sec sec Watts Watt Watt Vatios Nennleistung in Watt English Français Italiano Español Deutsch R Restrike time Temps de Tempo di Tiempo de Wiederzündzeit mins Réamorçage min riaccensione min reencendido min min 100 H RT Ballast Choke Ballast Ball...

Page 5: ...ili per applicazioni in teatro studio e locali notturni 4 GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 5 GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE PAR lamps provide a robust and flexible design solution for a wide range of theatre studio and nightclub applications PAR Lamps PAR 36 6 8 PAR 46 9 10 PAR 56 11 12 PAR 64 13 17 Super PAR 64 PAR 64 PAR 56 PAR 36 Lampes Par Les lampes P...

Page 6: ...4 300 12 A 42838 50 12 50PAR36 VNSP 25000 11x9 2000 12 A 12892 50 12 50PAR36 NSP 9200 20x17 11x9 2000 12 A 16540 50 12 50PAR36 WFL 1300 48x41 36x28 2000 12 A 16541 50 12 50PAR36 WFL H 3050 4000 12 19880 50 12 50PAR36 VWFL 600 80x80 40x37 2000 12 A 16542 50 28 4502 10000 40x7 400 12 24627 50 28 4505 45000 11x5 400 12 24640 100 13 4509 110000 12x6 25 12 24650 100 13 4509X 110000 12x6 25 12 41503 100...

Page 7: ...12 24795 250 28 4553 300000 11x12 25 12 E 24799 450 28 4580 400000 13x14 10 12 24859 450 28 4581 400000 13x14 10 12 24862 450 16 5 4635 325000 14x15 25 12 33284 450 28 Q4554 65000 50x11 25 12 37706 450 28 Q4597 16000 60x35 1000 12 37372 450 28 Q4681 310000 15x9 50 12 36271 146 95 PAR Lamps continued PAR 36 Screw Terminal cap continued Peak Approx Beam Spread Rated Intensity Colour 10 50 Average Pa...

Page 8: ... 18x9 2000 12 19024 120 12 120PAR56 WFL 5625 50x25 35x18 2000 12 19025 200 30 200PAR 270000 9x9 500 12 20122 240 12 240PAR56 VNSP 140000 7x10 9x6 2000 12 C 20575 240 12 240PAR56 MFL 46000 28x15 18x9 2000 12 C 20576 240 12 240PAR56 WFL 13000 50x27 35x18 2000 12 C 20577 300 12 300PAR56 WFL 1000 12 23427 178 114 PAR 46 Medium Side Prong cap Peak Approx Beam Spread Rated Intensity Colour 10 50 Average...

Page 9: ...56 WFL 10000 2000 12 C 20854 300 240 300PAR56 NSP 40000 2000 12 C 18676 300 240 300PAR56 MFL 30000 2000 12 C 18677 300 240 300PAR56 WFL 10000 2000 12 C 18678 500 120 Q500PAR56 NSP 96000 2950 32x15 13x8 4000 6 CD 43494 500 120 Q500PAR56 MFL 43000 2950 42x20 26x10 4000 6 CD 43495 500 120 Q500PAR56 WFL 19000 2950 66x34 44x20 4000 6 CD 43496 178 127 PAR Lamps continued PAR 64 Screw Terminal cap Peak A...

Page 10: ...8 500 230 500 PAR64 MFL 2700 32x19 21x10 2000 12 CD 39411 500 230 500 PAR64 W FL 2700 2000 12 CD 39414 1000 230 CP60 EXC SUPER 352000 3200 12x9 20x17 300 6 CD 93409 1000 240 CP60 EXC SUPER 352000 3200 12x9 20x17 300 6 CD 10925 1000 230 CP61 EXD SUPER 297000 3200 14x10 22x20 300 6 CD 10928 1000 240 CP61 EXD SUPER 297000 3200 14x10 22x20 300 6 CD 10929 1000 230 CP62 EXE SUPER 138000 3200 24x11 38x20...

Page 11: ... 500PAR64 MFL 37000 2800 35x19 23x11 2000 12 CD 39409 1000 120 FFN 400000 3200 24x10 12x6 800 6 CD 13233 1000 120 FFP 330000 3200 26x14 14x7 800 6 CD 13229 1000 120 FFR 125000 3200 44x11 28x12 800 6 CD 13228 1000 120 FFS 40000 3200 71x45 48x24 800 6 CD 13227 1000 120 FGN 70000 5200 43x20 27x11 200 6 CD 13225 1000 120 Q1000PAR64 NSP 200000 3000 31x14 15x8 4000 6 CD 43497 1000 120 Q1000PAR64 MFL 800...

Page 12: ...l an Lampen wurde entworfen um eine optimale Leistung in der heutigen Präzisionsauswahl an Bühnen Studio und architektonischer Beleuchtung zu bieten Lámparas Halogenas Bipin Un amplio rango de lámparas diseñadas para un óptimo rendimiento dentro de los aparatos de iluminación de precisión utilizados actualmente en la iluminación espectacular Lampade Alogene ad Attacco Singolo Una vasta gamma di la...

Page 13: ...4x7 105 20 60 5 300 24 W 39738 1 1000 240 CP77 FEP 25000 3200 CC 8 24x7 105 20 60 5 300 24 W 39736 1 Single Ended Halogen B A C Fig 1 High Performance Lamps Approx A B C Rated Initial Colour Filament Type Length Diameter LCL Average Pack Product Fig Watts Volts Order Code Lumens Temp K Form H x W mm mm mm Life Hours Quantity Code No 575 230 HPL 575 14900 3200 SCH 10 x 9 5 106 18 60 3 300 12 37128 ...

Page 14: ... 15 5x13 5 90 23 46 400 24 39635 1 650 240 T26 GCS 15500 3100 MP 15 5x13 5 90 23 46 400 24 39636 1 650 120 CP89 FRK 16900 3200 MP 12 5x11 5 90 25 46 200 24 39637 1 650 230 CP89 FRL 16250 3200 MP 13x13 90 25 46 150 24 39640 1 650 240 CP89 FRM 16250 3200 MP 13x13 90 25 46 150 24 39642 1 S Staggered Filament Burning position VBD 90 GY9 5 base Coiled Coil Filament 600 120 FMR 12600 3050 CC 8 16x6 85 1...

Page 15: ...6000 3200 MP 18 5x17 5 110 35 55 200 12 39653 1 1000 115 120 T11 Q1000T8 CL 23500 3050 MP 16x14 110 35 55 750 24 29331 1 1000 230 T11 23000 3050 MP 17 5x17 5 110 35 55 750 12 39656 1 1000 240 T11 23000 3050 MP 17 5x17 5 110 35 55 750 12 39659 1 1000 230 T19 FWP 21000 3050 BP 15x12 110 35 55 750 12 HJ 39657 2 1000 240 T19 FWR 21000 3050 BP 15x12 110 35 55 750 12 HJ 39658 2 1000 230 CP70 FVA 25000 3...

Page 16: ...5 40 90 400 12 30394 4 2000 240 CP92 52000 3200 BP 18 5x17 175 40 90 400 12 30397 4 2500 230 CP91 67500 3200 BP 24x18 175 40 90 400 12 30415 4 2500 240 CP91 67500 3200 BP 24x18 175 40 90 400 12 30423 4 Burning position VBD 90 B A C B A C B A C Fig 2 Fig 3 Fig 4 B A C Fig 1 GY16 base Approx A B C Rated LIF Initial Colour Filament Type Length Diameter LCL Average Pack Product Fig Watts Volts Code Or...

Page 17: ... 9 250 12 W 30533 2 1000 230 T14 FKD 23000 3050 MP 17 5x17 5 130 35 55 5 750 12 20385 4 1000 240 EWE 26500 3200 CC 8 24x6 152 20 88 9 250 12 W 30534 2 1000 240 T14 23000 3050 MP 17 5x17 5 130 35 55 5 750 12 20388 4 1000 240 T15 FKE 23000 3050 MP 17 5x17 5 160 35 88 9 750 12 30532 1 1000 240 CP52 FKN 26000 3200 MP 18 5x17 5 130 35 55 5 200 12 30546 4 Burning position VBD 90 B A C B A C B A C B A C ...

Page 18: ...2 127 400 12 31844 3 2000 240 CP41 FKK 54000 3200 MP 22x22 5 216 32 127 400 12 31849 3 2500 230 CP94 67500 3200 BP 24x18 210 40 127 400 12 30499 3 2500 240 CP94 67500 3200 BP 24x18 210 40 127 400 12 30500 3 3000 230 HX48 82000 3200 MP 24x26 210 47 127 400 12 K 30503 4 3000 240 HX48 82000 3200 MP 24x26 210 47 127 400 12 K 30504 4 5000 120 CP29 DPY 143000 3200 MP 31x36 280 65 165 500 6 41736 1 5000 ...

Page 19: ...300 12 L 30515 1 1250 2500 240 CP58 27000 59000 91000 3200 TF 27 5x25 24x22 220 70 143 300 12 L 30517 1 2500 2500 230 CP32 59000 127000 3200 TF 27 5x25 x2 220 70 143 300 12 L 30518 1 2500 2500 240 CP32 59000 127000 3200 TF 27 5x25 x2 220 70 143 300 12 L 30519 1 Burning position VBD 45 B A C B A C GX38 base Single ended High Wattage Halogen Lamps Approx A B C Rated LIF Initial Colour Filament Type ...

Page 20: ... 30522 2 2000 230 CP53 54000 3200 MP 22x22 5 200 40 87 400 12 20311 2 2000 240 CP53 54000 3200 MP 22x22 5 200 40 87 400 12 20312 2 Burning position VBD 90 B A C Fig 1 B A Fig 2 E40 base Clear Coil Filament Approx A B C Rated LIF Initial Colour Filament Type Length Diameter LCL Average Pack Product Fig Watts Volts Code ANSI Code Lumens Temp K Form H x W mm mm mm Life Hours Quantity Notes Code No 20...

Page 21: ...n Die Genauigkeit der Quarzlampen sind weltweit in den Fernsehstudios verbreitet Lámparas Halógenas Lineales Este rango de lámparas de cuarzo de alta precisión es ampliamente utilizado en los estudios de televisión de todo el mundo Lampade Alogene Lineari Questa gamma di lampade alogene è usata negli studi di produzione televisiva di tutto il mondo Lampes Halogenes Lineaires Cette gamme spécifique...

Page 22: ...LIGHTING CATALOGUE 39 GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 38 Double Ended Quartzline Lamps with R7s Caps A B 11 4 Fig 1 Length 79 4mm Approx A B Rated LIF Initial Colour Filament Lighted Length Diameter Average Pack Product Fig Watts Volts Code Order Code Lumens Temp K Form Length mm mm Life Hours Quantity Notes Code No 650 120 P2 6 FAD 16500 3200 CC 8 79 4 13 5 100 24 C 30325 1 8...

Page 23: ...3200 C 8 119 1 11 400 12 23756 1 800 240 P2 11 EME Clear 22000 3200 C 8 119 1 11 150 12 23760 1 800 240 P2 11 EMF Frosted 21400 3200 C 8 119 1 11 150 12 23761 1 1000 120 P2 28 FCM 28000 3200 C 8 119 1 11 400 12 23797 1 Linear Halogen Continued 41 A B 25 Fig 2 Length 142 9mm Burn Horizontal 4 RX7s Caps Approx A B Rated LIF Initial Colour Filament Lighted Length Diameter Average Pack Product Fig Wat...

Page 24: ...g Watts Volts Code Order Code Lumens Temp K Form Length mm mm Life Hours Quantity Notes Code No 625 230 P2 10 16900 3200 C 8 189 1 12 300 12 19697 1 625 240 P2 10 16900 3200 C 8 189 1 12 300 12 19698 1 1000 230 P2 7 EKM 28000 3200 C 8 189 1 12 300 12 20249 1 1000 240 P2 7 EKM 28000 3200 C 8 189 1 12 300 12 20253 1 1250 230 P2 12 35000 3200 C 8 189 1 12 300 12 19695 1 1250 240 P2 12 35000 3200 C 8 ...

Page 25: ...Projector Single Ended Capsules Projector Projektionslampen Eine komplette Auswahl an speziellen Projektionslampen entworfen um eine ausgezeichneten optischen Performance und Verlässlichkeit zu bieten Lámparas de Proyección Un rango completo de lámparas especiales para proyección diseñadas para proporcionar un excelente rendimiento óptico y una gran fiabilidad Lampade da Proiezione Una gamma compl...

Page 26: ...3 0 3400 44 30 50 G6 35 100 M 18235 1 150 24 DZE FDS A1 262 5000 BDTH C 6 Oval 6 4x3 8 3250 68 33 100 GZ9 5 24 M 37695 8 150 24 FCS A1 216 4500 BDTH C 6 Oval 6 4x3 8 3300 51 30 50 G6 35 100 M 13598 1 175 24 EML 5000 BDTH C 6 5 3x4 8 3200 54 27 125 G5 3 24 M 42612 3 250 24 EHJ A1 223 9000 BDTH C 6 Oval 7 6x3 8 3400 57 33 50 G6 35 100 M 14874 1 275 24 FNT 10000 BDTH C 6 Oval 3 5x7 1 3400 57 33 50 G6...

Page 27: ...0 A1 244 13000 BDTH MP 75 28 5 36 5 75 GY9 5 24 MN 39643 2 500 240 A1 244 13000 BDTH MP 75 28 5 36 5 75 GY9 5 24 MN 39644 2 650 240 A1 247 17750 BDTH MP 75 28 5 36 5 75 GY9 5 24 MP 39650 2 800 220 230 A1 245 21500 BDTH MP 87 28 5 44 5 75 GY9 5 24 MP 39648 2 800 240 A1 245 21500 BDTH MP 87 28 5 44 5 75 GY9 5 24 MP 39649 2 Specialist Projector continued C A C A C A Fig 4 Fig 5 Fig 3 G17q cap Approx ...

Page 28: ...02 2 100 12 M28 EVA 44 12 30 2400 3000 GY6 35 C 6 Oval 2000 20 34676 3 250 24 M33 55 13 5 33 8600 3000 G6 35 C 6 Oval 300 100 34768 3 250 24 M36 58 15 30 5750 3000 G6 35 C 6 Oval 2000 100 29231 4 Specialist Projector continued B C A Fig 4 Fig 5 B C A Mains Voltage single ended capsule A B C Rated Length Diameter LCL Average Colour Average Pack Product Fig Watts Volts LIF Code mm mm mm Lumens Temp ...

Page 29: ...CC 6 44 45 50 67 3350 GX5 3 20 MV 43206 1 80 21 DDS Microfilm 1000 165 CC 6 44 45 50 67 3125 GX5 3 20 MV 43988 1 GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 53 GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 52 Double ended lamps with R7s caps A B Fig 1 Linear Projector Lamps Rated A B Approx ANSI LIF Primary Average Length Diam Colour Pack Product Fig Watts Volts Code Code Applicati...

Page 30: ... 259 16mm Colour printer 50 30 CC 6 44 45 50 67 3400 GX5 3 20 MV 37462 1 250 24 ELC500 Disco 500 30 CC 6 44 45 50 67 3250 GY5 3 20 MV 15377 1 250 120 ENH Slide projection 175 155 CC 8 44 45 50 67 3250 GY5 3 20 MV 38686 3 300 120 ELH Slide projection 35 155 CC 8 44 45 50 67 3350 GY5 3 10 MV 38476 1 300 120 ENG Slide projection 15 155 CC 8 44 45 50 67 3450 GY5 3 10 MV 38685 3 Specialist Projector co...

Page 31: ...5 CC 6 44 45 50 67 3200 GX5 3 10 MV 40248 1 90 14 5 EPV Microfilm 500 155 CC 6 44 45 50 67 3150 GX5 3 20 MV 41882 1 90 14 5 EPX Microfilm 500 165 CC 6 44 45 50 67 3150 GX5 3 20 MV 42614 1 150 120 ESD Enlarger projection 12 45 CC 8 44 45 50 67 3350 GY5 3 20 MV 43756 2 150 120 EZK Camera light 200 CC 8 44 45 50 67 3200 GY5 3 20 MV 15477 2 200 24 EWF Overhead projection 50 300 CC 8 44 45 50 67 3300 G...

Page 32: ...ilm 500 76 or 175 CC 6 40 35 3 3050 GZ4 10 MV 31964 1 MR 13 Faceted Dichroic Reflector Rated Typical A B Approx ANSI LIF Primary Average Working Length Diam Colour Pack Product Fig Watts Volts Code Code Application Life Hours Distance Filament mm mm Temp K Cap Quantity Notes Code No 250 82 EXY Slide projection 200 150 CC 8 44 4 42 4 3200 GX5 3 10 MV 12097 2 225 68 EZF EZJ Colour printer 500 CC 8 4...

Page 33: ...BDTH CC 6 42 2 44 4 3400 GX7 9 24 40017 1 Fig 2 Specialist Projector continued High Intensity Arc Typical Rated Approx ANSI Working Average Colour Pack Product Fig Watts Volts Code Description Bulb Cap Distance Life Hours Temp K Qty Notes Code No 300 35 EZG Gemini 300 EZG Quartz Arc Tube in Special 2 pin 37 75 6000 4 11134 2 50mm dichroic reflector polarized plug 350 45 EZT Marc 350 16T EZT Quartz...

Page 34: ...en wurden eingeführt als Sortimentserweiterung im Entladungslampenbereich für die Bühnen und Studiobeleuchtung Lámparas de Descarga Nuevas lamparas CSR y CSD han sido lanzadas al mercado para incrementar el rango de productos de descarga para uso en aplicaciones de Estudio y Teatro Lampade a Scarica Le nuove lampade CSR CSD sono state introdotte per implementare la gamma delle lampade scarica util...

Page 35: ...49492 575 7200 95 GX9 5 CLEAR UNIVERSAL 1000 49000 CSR575 2 SE 10 15378 700 7200 72 G22 CLEAR UNIVERSAL 1000 55000 CSR700 2 SE 10 49491 1200 7200 100 G22 30x53 CLEAR UNIVERSAL 1000 110000 CSR1200 2 T SE 6 15379 1200 7200 100 G22 30x53 CLEAR UNIVERSAL 1000 110000 CSR1200 2 SE 6 49490 Double Ended Hot Restrike 200 6000 X515 CLEAR HORIZONTAL 15 300 16000 CSR200 DE 10 48450 6 575 6000 SFc 10 4 Sleeve ...

Page 36: ...SAL 10000 10000 4700 CMH70 PAR30 830 E27 FL 41620 4 Architainment PAR64 150 TBA TBA PAR64 GX16d TBA TBA TBA TBA TBA CMH PAR64 150W GX16d NSP TBA 150 TBA TBA PAR64 GX16d TBA TBA TBA TBA TBA CMH PAR64 150W GX16d MF TBA 150 TBA TBA PAR64 GX16d TBA TBA TBA TBA TBA CMH PAR64 150W GX16d WFL TBA Available late 2003 Stage Studio 150 4200 96 G12 CLEAR UNIVERSAL 6000 6000 12900 CMH150 SA G12 TBA Available l...

Page 37: ...00 6300 CMH70 E U 830 E27 C 46189 5 100 3000 80 ED17 E27 CLEAR UNIVERSAL 15000 10000 9200 CMH100 E U 830 E27 C 46191 5 Elliptical Diffuse 70 3000 80 ED17 E27 DIFFUSE UNIVERSAL 15000 15000 6000 CMH70 E U 830 E27 D 46187 6 100 3000 80 ED17 E27 DIFFUSE UNIVERSAL 15000 10000 8700 CMH100 E U 830 E27 D 46194 6 250 3000 80 ED28 E40 DIFFUSE UNIVERSAL 15000 15000 23500 CMH250 E VBU 830 E40 D 10591 6 400 30...

Page 38: ... BP G22 base medium bipost Average Colour Colour Arc Code Lumens Life Colour Chromaticity Rendering Burning Gap Lamp Watts Ref 100 hrs Maintenance Hours Temp K Co ordinates Index Ra Position Width Base Volts 1000 77 99 0221 90000 85 at 500 hrs 500 4000 400 x0 385 80 VBD 90 14 1 CSI y0 395 H 100 CRI BP mm Run Up Starting Restrike Current Time Pulse nom Time Ballast Product Fig amps Sec max KV Mins ...

Page 39: ...x KV Mins Ignitor Choke Capacitor Code No 7 60 9 Peak 5 G53444 or IREM 4xGC2331 30563 1 Bag Turgi SE15 7U ZA57 80µF 250V 15 60 9 Peak 5 G53444 or G53307 T 7xGC2346 30561 2 Bag Turgi SE15 7U 175µF 250V Special Bipin base Average Colour Colour Arc Code Lumens Life Colour Chromaticity Rendering Burning Gap Lamp Watts Ref 100 hrs Maintenance Hours Temp K Co ordinates Index Ra Position Width Volts 200 ...

Page 40: ...Rendering Burning Gap Lamp Watts Ref cd Degrees Degrees Life Hours Temp K Co ordinates Index Ra Position Width Volts 1000 77 99 1225 850000 8 20 1500 5500 400 x0 333 85 HOR 90 15 1 5 CID y0 341 1000 77 99 1425 850000 8 20 1000 5500 400 x0 333 85 HOR 90 15 1 5 CID y0 341 1200 100 99 1435 820000 9 18 1000 5500 400 x0 332 85 HOR 90 18 1 CID y0 341 Run Up Starting Restrike Current Time Pulse nom Time ...

Page 41: ... capacitance between igniter and lamp 50pF 300mm length Lp N R 100 2 5W 9kV 400 Watt CSI Lamp Circuit Diagram Ballast G53307 T 20A HBC MCB Fuse PFC 175µF 250V 7xGC2346 L N 220 240V 50Hz Supply B G53444 or Bag Turgi SE 15 7U Igniter 1000W CSI Lamp Ref 99 1222 or 99 0221 Lampholder for 99 1222 Bender Wirth 938 223 and for 99 0221 Bender Wirth 933 1419 Maximum cable capacitance between igniter and la...

Page 42: ...r 2 second ON timer Maximum cable capacitance between igniter and lamp 30pF 200mm length 1 2 2 3 G Lampholder Bender Wirth type 938 223 HT HT 50kV 1200 Watt CID Hot Restart Lamp Circuit Diagram Ballast 2xG53307 T in parallel 40A HBC MCB Fuse PFC 275µF 250V 11xGC2346 L N 220 240V 50Hz Supply Sw R 50 2 5W C 2µF 250V 2500W CID Lamp Ref 99 0431 Sw Normally open contacts Manual switch or 2 second ON ti...

Page 43: ...35 F20T12 CINEMA32 HO CVG Indoor 7000 24 15775 2 35 F20T12 CINEMA55 HO CVG Daylight 7000 24 15776 2 40 F40T12 CIN55 Daylight 20000 30 47864 2 40 F40T12 CIN32 Indoor 20000 30 47857 2 40 F40T12 CIN55 CVG Daylight 20000 30 47877 2 40 F40T12 CIN32 CVG Indoor 20000 30 47876 2 75 F40T12 CINEMA32 HO Indoor 12000 30 15716 2 75 F40T12 CINEMA55 HO Daylight 12000 30 15717 2 75 F40T12 CINEMA32 HO CVG Indoor 1...

Page 44: ...gned by the American National Standards Institute They provide a system for assuring mechanical and electrical interchangeability among similarly coded lamps from various manufacturers CP Prefix Lamps designed for use in conjunction with film balanced for 3200K These are single ended types intended for use in Fresnel ellipsoidal luminaires etc P2 Prefix Again for use with 3200K film stock for open...

Page 45: ...gs use the IEC International designations for lamp bases Where appropriate alternative local descriptions are appended GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE Incandescent tungsten halogen lamps Filament Format The listings use the following codings for filament shape S C Axial Single Coil equivalent to ANSI C8 C C Axial Coiled Coil equivalent to ANSI CC8 M P Monoplane Grid equivalent...

Page 46: ...gives fittings manufacturers a comprehensive range of compact lamps and permits the construction of smaller lighter and more efficient luminaires GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 87 Glossary of basic product information Rated Average Life Average life ratings of Projection Lamps are based on closely controlled laboratory tests of lamps at their rated voltage over a long period ...

Page 47: ...s dimension includes the lamp bulb and all rigid parts of the base Since the listed lengths include maximum tolerances actual lamps are generally slightly shorter GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 89 Approximate Initial Lumens The value shown is based on spherical photometry at rated voltage of lamps that have been seasoned for approximately 15 or a minimum of 2 hours or more of...

Page 48: ...he suitability of a lamp for his intended application or use and to assume the responsibility for that determination General Electric desires to supply the best possible products at all times For this reason General Electric reserves the right to make changes in its products when it believes such changes will improve its products GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 91 Operating No...

Page 49: ... lamp e g at over voltage or at burning angles not designated for the lamp type or rating Operate inseries with a quick acting high breaking capacity fuse of suitable rating Non observation of these points may damage the lamp or equipment 5 In operation a lamps develop a high internal pressure and could shatter b lamps develop a high surface temperature c direct exposure may cause UV irritation to...

Page 50: ... and cause injury if broken Do not use lamp if outer glass is scratched or broken Dispose of lamp in a closed container ANSI notice for Stage Studio unshielded lamps Warning Risk of electric shock Turn power off before inspection installation or removal Risk of fire Keep combustible materials away from lamp Use in fixture rated for this product Pressurized lamp unexpected rupture may cause injury ...

Page 51: ...should be operated only in well ventilated locations 5 Metal halide lamps with quartz envelopes without glass outer bulbs may emit short wave ultra violet radiation which is harmful to eyes and skin Operators must be shielded from direct or indirect short wave ultra violet radiation GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 97 Planar MP C13 Monoplane Filament designation The configurati...

Page 52: ...llipsoidal Spotlights A problem is encountered with some ellipsoidal spotlight luminaires due to the fact that a portion of the reflected beam of light is directed onto the cap of the lamp designed for Fresnel fittings This leads to overheating of the cap and seal which may result in premature lamp failure GE have therefore designed lamps intended for use in ellipsoidal spotlights where the size o...

Page 53: ...oration from the filament prolongs the life of the lamp to at least twice that of a glass lamp of equivalent efficacy GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 101 Biplane or Monoplane The filament format of a lamp will have an effect on the beam performance of a luminaire In Fresnel optics a biplane filament will due to its smaller area produce a narrower spot of slightly increased pea...

Page 54: ...ish The rate of loss of hydrogen during lamp operation is less than previously predicted and based upon spectraradiometer measurements and calculations maximum protection is only required during the initial 50 hours of life Hence the use of hydrogen additions is the most advantageous method of ensuring reliable operation of lamps during early life particularly in demanding operating conditions GE ...

Page 55: ...NT LIGHTING CATALOGUE 104 Lamp comparison and construction GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE A typical low wattage theatre class tungsten halogen lamp Exhaust tip off Quartz bridge Filament hook Filament Quartz envelope Pinch seal Cement Outlead P28 shell Seal foil Ceramic insert Fuse Gas filling End section of a typical quartz linear tungsten halogen lamp Tungsten support Quart...

Page 56: ...LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 107 Calculations of lamp life achievement taken from this graph should be considered strictly theoretical as the life factor is considerably influenced by frequency of switching environment vibration handling cleaning etc This graph is based on the average achievement of numerous lamp tests and thus should only be used as an approximate guide to pe...

Page 57: ...ing with temperature and is frequently the cause of short life due to seal failure Bulb 250 800 C Outside this range the halogen cycle becomes less efficient and blackening may occur Temperatures above 1200 C will cause the bulb to soften Pins 350 C maximum Above this figure the plating on the pins may lose adhesion and the contact will deteriorate Such deterioration may form local hot spots which...

Page 58: ... the then extremely high surge current on switching lamp type cold max surge current amps normal resistance line impedance operating ohms 0 ohms 0 1 ohms 0 3 ohms 0 5 ohms current 240V 10kW 0 34 1000 774 530 405 41 5 240V 5kW 0 7 486 424 340 283 20 8 115V 5kW 0 15 1085 650 360 250 43 5 240V 2kW 1 7 200 189 170 154 8 35 117V 2kW 0 41 404 324 233 182 17 1 240V 1kW 3 4 100 97 92 87 4 15 GE LIGHTING S...

Page 59: ...tage lamps are dimmable to 50 of peak lumens and the great majority are available in hot re strike versions for applications where frequent changes in lighting levels are required All lamps will re strike within ten minutes of switch off GE LIGHTING SHOWBIZ ENTERTAINMENT LIGHTING CATALOGUE 113 Compact Iodide Daylight CID Discharge Lamps With a colour temperature of 5500K these lamps provide an exc...

Page 60: ...ife Operation outside of these figures will not necessarily cause immediate failure but will effect life adversely to an increasing extent Cap bulb interface capsule lamps 450 maximum Above this figure the sealing foil oxidises at a rate increasing with temperature and is frequently the cause of short life due to seal failure Bulb capsule lamps 700 1000 C sealed beam lamps 150 400 C Above 1000 C q...

Page 61: ...r manner N B For sealed beam lamps to ensure that the above conditions are met it is important that the lamp does not operate above 400 C even in an enclosed fitting Fusing of Discharge Studio and Theatre Lamps A quick acting high breaking capacity fuse must be connected in the supply line in all applications Suitable types are given in BS88 IEC 60269 IEC 60127 or IEC 60241 See page 111 for suitab...

Page 62: ...0PAR36 WFL H 7 150PAR46 3MFL 10 200PAR46 3MFL 10 120PAR56 VNSP 11 120PAR56 MFL 11 120PAR56 WFL 11 200PAR 11 240PAR56 VNSP 11 240PAR56 MFL 11 240PAR56 WFL 11 Index Lamp type page 300PAR56 NSP 12 300PAR56 MFL 12 300PAR56 WFL 12 500PAR64 NSP 17 500PAR64 MFL 17 Q500PAR56 NSP 12 Q500PAR56 MFL 12 Q500PAR56 WFL 12 Q500PAR64 VNSP 15 Q500PAR64 NSP 15 Q500PAR64 MFL 15 500PAR64 WFL 15 500PAR64 MFL 15 Q1000PA...

Page 63: ...7 4405 7 4435 9 4502 7 4505 7 4509 7 4509X 7 4511 7 4515 7 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page H4515 7 4516 7 4531 9 4535 9 4537 7 4537 2 9 4545 11 4546 7 4547 7 4551 9 4552 13 4553 9 Q4554 9 4559 13 Q4559 13 Q4559X 13 4570 9 4571 9 4572 9 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Stud...

Page 64: ...6 8 4627 8 4635 9 Q4597 9 Q4681 9 H7604 7 H7616 7 H7635 9 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page Theatre lamps by LIF code T11 25 T12 25 T13 29 T14 29 T15 29 T16 35 T17 28 T18 23 T19 25 T25 23 T26 23 T27 23 T28 28 T29 25 OC1200 27 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio ...

Page 65: ...3 26 CP51 29 CP52 29 CP53 35 CP58 33 CP59 34 CP60 15 CP61 15 CP62 15 CP70 25 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page CP77 21 CP79 26 CP81 22 CP82 22 CP83 31 CP86 15 CP87 15 CP88 15 CP89 23 CP90 25 CP91 27 CP92 27 CP93 27 CP94 31 CP95 15 CP105 33 HX48 31 HX270 31 HX800 21 Disco Theatre Stage Photographic Micrographic Audio visual Ou...

Page 66: ...750 20 HPL750 C 20 HPL750 XLL 20 Theatre TV Film Studio lamps by ANSI code BTM 28 CYX 31 DKX DSF 33 DKZ DSE 33 DPY 31 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page DTA 34 DWE 8 EGE 28 EGJ 29 EGN 27 EGT 27 EHD 21 EHF 21 EHG 21 EWE 29 FBE 8 FBO 8 FCX 6 FCW 9 FEL 21 FEP 21 FFN 17 FFP 17 FFR 17 Disco Theatre Stage Photographic Micrographic A...

Page 67: ...9 FKN 29 FKR 21 FKW 22 FLK 21 FLK LL 21 FMR 23 FRE 23 FRG 22 FRH 22 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page FRJ 22 FRK 23 FRL 23 FRM 23 FSK 22 FSL 22 FTL 26 FTM 26 FVA 25 FVB 25 FWP 25 FWR 25 FWS 25 FWT 25 GCS 23 GCT 23 GCV 23 GCW 23 GKV 21 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio ...

Page 68: ...s by ANSI code DXW 39 DXX 38 EHM 40 EKM 42 EJG 40 EME 40 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page EMF 40 FAD 38 FBY 39 FCL 40 FCM 40 FEX 41 FEY 41 Single Ended Hot restrike CSR 12S SE HR 64 CSR 200 SE HR 64 CSR 575 SE HR 64 CSR 1200 SE HR 64 CSR 2500 SE HR 64 CSR 4000 SE HR 64 CSR 6000 SE HR 64 CSR 12000 SE HR 64 Disco Theatre Stage...

Page 69: ...500 DE 65 CSR 4000 DE 65 CSR 6000 DE 65 CSR 12000 DE 65 CSR 18000 DE 65 CSR 18000S DE 65 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page CMH SINGLE ENDED MINIS 66 SINGLE ENDED 66 PAR 67 DOUBLE ENDED 67 ELLIPTICAL CLEAR 68 ELLIPTICAL DIFFUSE 68 TUBULAR CLEAR 68 Discharge lamps CSI 99 0201 70 99 0221 71 99 1222 71 99 1422 71 CID 99 0211 72 9...

Page 70: ...AX COMPACT FLUORESCENT 79 LINEAR FLUORESCENT 79 81 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page Specialist Projector lamps by LIF code A1 215 47 A1 216 47 A1 220 47 A1 223 47 A1 226 52 A1 227 52 A1 229 53 A1 230 53 A1 231 54 A1 232 54 A1 233 47 A1 234 47 A1 239 47 A1 241 49 A1 244 48 A1 245 48 A1 247 48 A1 248 48 Disco Theatre Stage Pho...

Page 71: ...X501 47 HX185 47 Specialist Projector lamps by ANSI code BRH 47 BRJ EVB 47 BRL 47 CBA 49 DDL 54 Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page DDM 53 DDN 52 DDS 53 DED 54 DJT 53 DNF 55 DWZ 52 DYR 47 DYS 47 DZA 47 DZE FDS 47 EFM 53 EFN 53 EFP 54 EFR 54 EHJ 47 EJA 55 EJL 54 EJM 54 Disco Theatre Stage Photographic Micrographic Audio visual O...

Page 72: ...EMM EKS 60 ENG 54 ENH 54 ENL 57 ENW ENC 57 ENX 57 EPS 49 Lamp type page Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio Lamp type page Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio EPT 57 EPV 57 EPW 57 EPX 57 EPZ 57 ERV 57 ESA 50 ESB 50 ESD 57 EVA 50 EVD 47 EVV 47 EVW 57 EWF 57 EWR 47 EXL 47 EXR 59 EXW 59 EXX...

Page 73: ...graphic Audio visual Outside Broadcast TV Film Studio EXY 59 EYA 57 EZF EZJ 59 EZK 57 EZM 61 EZT 61 FAL 52 FCR 47 FCS 47 FDT 47 FFJ 47 FHS 59 FHX 57 FLS 58 FLT 58 FLW 47 FML 57 FNT 47 FXL 57 140 141 Lamp type page Disco Theatre Stage Photographic Micrographic Audio visual Outside Broadcast TV Film Studio M28 50 M29 50 M30 50 M32 50 M33 50 M36 50 M38 51 M40 51 ...

Page 74: ...5 4132 1017 DENMARK GE Lighting A S Park Alle 295 DK 2605 Bröndby Tel 45 43 42 44 51 Fax 45 43 42 44 52 142 ARGENTINA GE Iluminacion S A Av San Martin S N Esquina 25 de Mayo 1618 El Talar Tigre Pcia de Buenos Tel 54 11 4736 6600 Fax 54 11 4736 6616 AUSTRALIA GE Lighting Australia Ltd 125 127 Long Street Smithfield NSW 2164 Tel 61 2 9729 0011 Fax 61 2 9729 1144 AUSTRIA GE Lighting Gmbh Praunheimer ...

Page 75: ...Fax 52 8 318 5693 NEW ZEALAND GE Lighting New Zealand Level 10 Lumley House 7 City Road Auckland Tel 64 9 353 6706 Fax 64 9 353 6707 NORWAY GE Lighting AS Karenslyst Allé 2 0214 Oslo Tel 47 23 28 21 00 Fax 47 23 28 21 09 ESTONIA LATVIA LITHUANIA Representative Office GE Hungary Tungsram Lighting Elizabetes 2 LV 1340 Riga LATVIA Tel 371 7 321 710 Fax 371 7 321 762 FINLAND GE Lighting Oy Malmin kaup...

Page 76: ...Negro Torre A Piso 6 Avenida La Estancia Chuao Caracas Tel 58 212 902 5131 Fax 58 212 902 5158 146 PERU ECUADOR GE Lighting Peru Av Garcilaso de la Vega 1420 Esquina Con Av Espana Lima PERU Tel 511 433 9862 Fax 511 332 0482 PHILIPPINES GE Lighting Philippines 1873 P Domingo Street 1207 Makati City Metro Manila POB 2087 MCC Tel 632 895 7051 Fax 632 890 8186 POLAND General Electric Co Polska Sp z o ...

Page 77: ...GE International Inc Suite 701 Central Building 31 Hai Ba Trung Str Hanoi Tel 844 8251016 Fax 844 8250551 YUGOSLAVIA VSD MERKUR dooel Exclusive Agent of GE Hungary Rt Oton Zupancic 32b 9 11000 Belgrade Tel 381 11 3193741 Fax 381 11 3193741 Web site www GELighting com ...

Reviews: