GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE
GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE
106
Variation of light output and wattage with
applied voltage for a typical studio lamp
160
120
80
40
0
60
80
100
120
% rated volts
% lumens and watts
105
100
95
80
90
100
110
120
% rated volts
% Change in colour temperature
watts
lumens
Colour temperature variation with voltage
for typical studio lamp
Lamp performance
GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE
GE LIGHTING - SHOWBIZ™ ENTERTAINMENT LIGHTING CATALOGUE
107
Calculations of lamp life
achievement taken from this
graph should be considered
strictly theoretical as the life
factor is considerably
influenced by frequency of
switching, environment,
vibration, handling, cleaning
etc. This graph is based on
the average achievement of
numerous lamp tests, and
thus should only be used as
an approximate guide to
performance.
300
200
100
90
100
110
120
% rated volts
% rated life
Typical life variation against
operation voltage
Spectral distribution of luminous flux (lumens)
for typical theatre and studio lamp
10
8
6
4
2
400
500
600
700
wavelength (nm)
Relative luminous flux
Violet Blue Green
Yellow
Red