32
EntelliGuard R Circuit Breaker Retrofill AKD-8 Installation Manual DEH41549 R05
Figure 20. AKD-8—Seven Bullets to a Block, Three Blocks
Figure 21. AKD-8—Seven Bullets to a Block, Three Blocks (Exploded View) (Model 1)
The secondary disconnect block assemblies (
Figure 21
) for the AKD8 version of the EntelliGuard Retrofill can
be purchased and installed. Here are the installation instructions:
For Model 1 AKD8 Retrofill Breakers
1.
Unpack the secondary disconnect block from the box. The kit comes in just one box. Each kit of
secondary disconnect has 4 nuts, plain washers, and spring washers. These can be arranged on a work
station for preparing to install the secondary disconnect blocks.
2.
Check that the bullets, on top of the secondary disconnects, are not damaged and that they slide in to
the blocks freely. The bullets are spring-loaded and return to their initial positions when they are released
from being pressed down.
3.
Check for electrical continuity between the bullets on one end and the wire terminations on the other.
Blocks containing faulty bullets should be replaced.