background image

Summary of Contents for DSKS433EB3WW

Page 1: ...ese instructions with the customer DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL This dryer must be connected to an individual branch circuit of proper voltage and frequency as specified on Rating Plate located inside dryer door with no other appliances or fixtures attached EXCEPTION A 120V receptacle is located on the back on the dryer and is available only for use with a washer that is ...

Page 2: ...E SUPPLY 208V 240V MODELS Connect two 2 HOTlines to outer screws L1 and L2 of terminal block Connect Neutral line to center screw N of terminal block REAR HOT WIRE GREEN HOT WIRE GROUNDING WHITE SCREW _ NEUTRAL GROUND WIRE STRAP POWER SUPPLY CORD 3 10 _ AWG MINIMUM COPPER CONDUCTORS 30 AMP 240V WITH TYPE UL RECOGNIZED MINIMUM RATED 90 C 208 OR 240 VOLTOPERATION N L 2 120 208 OR 120 240 2o8v or 24o...

Page 3: ...awl space attic under an enclosed floor or in any other concealed space of a building The accumulated lint could create a potential fire hazard Never terminate the exhaust into a common duct with a kitchen exhaust system A combination of grease and lint creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a pote...

Page 4: ...lbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying performance Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLY...

Reviews: