Marks and symbols on the instrument 
 

 

10.

 

S

PECIFICATION

:

 

 

Table 3: General Specification 

Display

 

LCD: Color display with touch-screen

 

Ingress  
Protection

 

IP54 rated

 

Shock /  
Vibration

 

BS EN 61010-1:2010 / MIL-PRF-28800F CLASS 

2

 

EMC

 

BS EN 61326-1:2013

 

Electrical safety

 

BS EN 61010-1:2010

 

Pressure safety

 

Pressure Equipment Directive - Class: Sound 

Engineering Practice (SEP)

 

Approved

 

CE Marked

 

 

 

 

 
Complies with 
European Union 
directives 

 

 

Warning 

  

refer to the 
manual 

 

Read the manual 

 

 

USB ports: 
Type A; 
Mini-type B 
connector 

 

Ground (Earth) 

 

 

ON / OFF 

 

Do not dispose of this product as household waste. 
See 

“Maintenance” 

(Section 4.3). 

More marks and symbols are specified in the user manual (Druck 
DPI611 Pressure Calibrator, K0571). 

Summary of Contents for Druck DPI611

Page 1: ...o 158 F Humidity 0 to 90 Relative Humidity RH Non condensing Power Supply 100 260 V 10 50 60 Hz AC Output DC V 5 A 1 6 A CATII of IEC60364 4 443 Pressure Ranges 1 barg 14 5 to 15 psig 1 to 2 barg 14 5...

Page 2: ...FRENCH FR GERMAN DE ITALIAN IT SPANISH ES PORTUGUESE PT RUSSIAN RU CHINESE ZH GREEK EL CZECH CS DANISH DA HUNGARIAN HU LITHUANIAN LT LATVIAN LV SWEDISH SV DUTCH NL NORWEGIAN NO POLISH PL TURKISH TR R...

Page 3: ...for Voltage V 24 V loop power supply 24 Vo 8 Liquid Crystal Display LCD Color display with touch screen To make a selection lightly tap on the applicable display area 9 5 V DC power input socket This...

Page 4: ...7 bar 5 mbar min QUICK REFERENCE Before using this instrument read and understand the Safety section It is dangerous to ignore the specified warnings This instrument is intended for indoor use only GE...

Page 5: ...upply in the temperature range 0 to 40 C 32 to 104 F PRESSURE WARNINGS Some liquid and gas mixtures are dangerous This includes mixtures that occur because of contamination Make sure that the equipmen...

Page 6: ...t parameters The DPI611 instrument measures and displays Pneumatic Pressure Vacuum generated by the instrument In addition it can measure source electrical signals 2 STANDARD EQUIPMENT These items are...

Page 7: ...18 4 lbf ft Attach the pressure adaptor to the DPI611 and tighten to finger tight 4 3 Maintenance Clean the case with a moist lint free cloth and a weak detergent Do not use solvents or abrasive mate...

Page 8: ...ing the cover upwards 2 Remove old batteries and dispose off in accordance with local instructions 3 Place the new batteries in the battery compartment with the correct orientation 4 Replace the batte...

Page 9: ...ssing and holding the power button until the screen is blank 2 Use Power OFF to preserve the battery capacity when the instrument is not in use for extended periods of time Standby Mode Press and Rele...

Page 10: ...e DASHBOARD displays icons representing the functional applications of the DPI611 for example the CALIBRATOR application Touch the appropriate icon to start the application When more choices are avail...

Page 11: ...USTOM TASK and manually configure the required measure and source functions CUSTOM TASK tasks can be saved for future use by adding them to FAVOURITES using the Save function in the TASK MENU 7 1 Set...

Page 12: ...e the applicable adaptor to attach the device See Figure 9 Step Procedure Vacuum 1 Set to vacuum operation 2 Turn the volume adjuster to mid range 3 Seal the system 4 Set the vacuum with the pump 5 Ad...

Page 13: ...C BS EN 61326 1 2013 Electrical safety BS EN 61010 1 2010 Pressure safety Pressure Equipment Directive Class Sound Engineering Practice SEP Approved CE Marked Complies with European Union directives W...

Page 14: ...Safety and Quick start guide 12 EN English K0565 Issue 1...

Reviews: