DigitalFlow™ XMT868i Startup Guide
5
Chapter 1. Installation
1.6 Mounting the XMT868i Electronics Enclosure
The standard model XMT868i electronics package is housed in a Type-4X weather-resistant enclosure suitable for
indoor or outdoor use. Refer to
for the mounting dimensions and the weight of this enclosure.
The Model XMT868i electronics enclosure is fitted with a mounting boss that has a single 3/4” NPTF threaded hole at
its center and four 1/4-20 tapped holes at its corners. By using this mounting boss, the electronics enclosure may be
mounted by any of the typical techniques shown in
.
1.7 Making Electrical Connections
This section contains instructions for making all the necessary electrical connections to the Model XMT868i flow
transmitter. Refer to
for a complete wiring diagram.
Except for the power connector, all electrical connectors are stored on their terminal blocks during shipment and may
be removed for more convenient wiring. Simply, feed the cables through the conduit holes on the side of the enclosure,
attach the wires to the appropriate connectors and plug the connectors back into their terminal blocks.
Refer to
and prepare the Model XMT868i for wiring by completing the following steps:
1.
Disconnect any previously wired power line from the unit.
2.
Loosen the set screw on the rear cover.
3.
Place a rod or long screwdriver across the cover in the slots provided, and rotate the cover counterclockwise
until it comes free from the enclosure.
4.
Install any required cable glands in the appropriate conduit holes around the side of the enclosure.
5.
Note the labels inside the rear cover to assist in wiring the power and option card connections. Also,
shows the rear cover option card labels for every available option card configuration.
Proceed to the appropriate section of this chapter to make the desired wiring connections.
WARNING!
Proper grounding of the XMT868i chassis is required to prevent the possibility of
electric shock. See
to locate the chassis grounding screw.
WARNING!
To meet CE Mark requirements, all cables must be installed as described in
Appendix A,
CE Mark Compliance
.
WARNING!
Always disconnect the line power from the Model XMT868i before removing either
the front cover or the rear cover. This is especially important in a hazardous environment.
CAUTION!
To ensure safe and reliable operation of the flow meter, be sure to install and tighten
all cable glands in accordance with the gland manufacturer’s instructions.
Summary of Contents for DigitalFlow XMT868i
Page 2: ......
Page 4: ...ii no content intended for this page ...
Page 28: ...Chapter 1 Installation 20 DigitalFlow XMT868i Startup Guide no content intended for this page ...
Page 34: ...Chapter 1 Installation DigitalFlow XMT868i Startup Guide 26 no content intended for this page ...
Page 86: ...Warranty 78 DigitalFlow XMT868i Startup Guide no content intended for this page ...
Page 90: ...Index 82 DigitalFlow XMT868i Startup Guide no content intended for this page ...
Page 92: ... no content intended for this page ...
Page 94: ... no content intended for this page ...
Page 95: ......