Dialog QS1500 Touchtalk Interactive Keypad Installation Instructions

 

4. Reattach the keypad to the mounting plate.

Testing the Keypad After Mounting

Note 

While the sensor test is a 
valuable installation and ser-
vice tool, it only tests sensor 
operation for the current 
conditions. You should per-
form a sensor test after any 
change in environment, 
equipment, or programming.

Repeat the steps listed in the “Performing a Sensor Test” section in this manual.

Keypad Operation

Numeric Buttons (0 - 9) - Used to enter an access code or turn individual lights on and off.

Disarm Button - The control panel is disarmed to level 0 or 1. (Level 0 all sensors except 
smoke alarms are disarmed. Level 1 doors, windows, and motion sensors are disarmed). Dis-
arm also requires the access code to be entered.

ARM Doors & Windows Button - The control panel is armed to level 2.

ARM Motion Sensors Button - The control panel is armed to level 3. If the ARM Doors & 
Windows button was previously pressed, the control panel is armed to level 4 (Doors/Win-
dows and Motion Sensors armed).

Lights On Button - Pressing this button twice quickly turns on all lights controlled by the sys-
tem. Pressing this button once plus 1-8 will turn on that individual numbered light.

Lights Off Button - Pressing this button twice quickly turns off all lights controlled by the sys-
tem. Pressing this button once plus 1-8 will turn off that individual numbered light.

Emergency Buttons - The panel will react according to the sensor group they are learned in to 
(00-07) Intrusion, Silent or Emergency. Press and hold both keys OR press both keys twice 
quickly, to activate alarm reports to the central station.

Battery Replacement

When the batteries get low on the keypad, the keypad announces “Touchpad low battery”. The 
panel announces “<Sensor name> low battery”.

Note 

Avoid pressing the buttons 
on the keypad during battery 
replacement.

Remove the touchpad from the mounting plate and replace all three batteries with AAA alkaline 
batteries.

After replacing the batteries, run a sensor test to realign the keypad to the panel.

Specifications

Compatibility:

..........................Simon 3 (version 3.3 and later)

Power Requirements:

..............3 AAA Alkaline batteries

Storage Temperature:

..............-40° to 140° F (-34° to 60° C) 

Operating Temperature:

.........32° to 120° F (0° to 49° C)

Maximum Humidity:

...............90% relative humidity, non-condensing

Dimensions:

..............................3.6 x 1.2 x 5.4 in. (W x D x H)

Installation:

..............................Wall mounting

Listings:

FCC Notice

7KLVGHYLFHFRPSOLHVZLWK)&&5XOHV3DUWV2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV

1.

This device may not cause harmful interference.

2.

This device must accept any interference that may be received, including interference that may cause undesired 
operation.

&KDQJHVRUPRGLILFDWLRQVQRWH[SUHVVO\DSSURYHGE\*(6HFXULW\FDQYRLGWKHXVHU·VDXWKRULW\WRRSHUDWHWKHHTXLSPHQW
)&&,'%=$:73

Notices

5HG)R[5RDG

$UGHQ+LOOV01

7HFKQLFDO6XSSRUW

)

‹*(6HFXULW\/HDUQ0RGHLVDWUDGHPDUNRI*(6HFXULW\6LPRQLVDUHJLVWHUHG

WUDGHPDUNRI*(6HFXULW\$OORWKHUWUDGHPDUNVDUHSURSHUWLHVRIWKHLURZQHUV

$OOULJKWVUHVHUYHG

*(6HFXULW\

Reviews: